Preferred Language
Articles
/
8Bcse44BVTCNdQwCX0nA
Fuzzy logic control of active suspension system equipped with a hydraulic actuator
...Show More Authors

In this paper, the Active Suspension System (ASS) of road vehicles was investigated. In addition to the conventional stiffness and damper, the proposed ASS includes a fuzzy controller, a hydraulic actuator, and an LVDT position sensor. Furthermore, this paper presents a nonlinear model describing the operation of the hydraulic actuator as a part of the suspension system. Additionally, the detailed steps of the fuzzy controller design for such a system are introduced. A MATLAB/Simulink model was constructed to study the proposed ASS at different profiles of road irregularities. The results have shown that the proposed ASS has superior performance compared to the conventional Passive Suspension System (PSS), where the body displacement can be minimized to about 70.1 % and the settling time is reduced to about 48.4 %. Also, the results have shown that the actuator force can reach 68 % of the body weight under the worst studied road conditions.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
Conference: 8th International Conference And Exhibition On Design And Production Of Machines And Dies/molds
Design, Construction, and Controlling of A Shaped Metal Deposition Machine Using Arc Metal-Wire System
...Show More Authors

Publication Date
Tue Oct 26 2021
Journal Name
Series On Biomechanics
Monitoring and analysis of plantar pressure map and foot motions using a wearable sensing system
...Show More Authors

Peer-Reviewed Journal

View Publication
Scopus (3)
Scopus
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
A Impact of High Voltage Direct Current Link on Transmission Line in Kurdistan Power System
...Show More Authors

Kurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Sep 12 2020
Journal Name
Al-kindy College Medical Journal
Spectrum of central nervous system infections in neurosciences hospital in two years : a retrospective study
...Show More Authors

Background :Infectious disorders in general have high morbidity and mortality.. CNS infections include many disorders like bacterial meningitis, tuberculous and other subacute and chronic meningitis, viral meningitis, cerebral abscess, spinal cord infections, and others.
Objective: To assess our locality about prevalence of CNS infections , to have more awareness regarding CNS infections, and to try to find the proper way to reduce their prevalence and to treat them in appropriate way.
Method :We revised the records of all the cases of CNS infections excluding cases of spinal cord infections who were admitted in the wards of neuroscience hospital over the previous two years ( from July/2010 to June 2012 ),those were 132 cases.Seaso

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Journal Of Engineering
Numerical Simulation of Unsaturated Soil Water from a Trickle Irrigation System for Sandy Loam Soils
...Show More Authors

Trickle irrigation is a system for supplying filtered water and fertilizer directly into the soil and water and it is allowed to dissipate under low pressure in an exact predetermined pattern. An equation to estimate the wetted area of unsaturated soil with water uptake by roots is simulated numerically using the HYDRUS-2D/3D software. In this paper, two soil types, which were different in saturated hydraulic conductivity were used with two types of crops tomato and corn, different values of emitter discharge and initial volumetric soil moisture content were assumed. It was assumed that the water uptake by roots was presented as a continuous sink function and it was introduced into Richard's equation in the unsaturated z

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Nov 01 2019
Journal Name
International Journal On Interactive Design And Manufacturing (ijidem)
A real-time automated sorting of robotic vision system based on the interactive design approach
...Show More Authors

View Publication
Scopus (36)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
Mesoporous Silica Nanoparticles as a System for Ciprofloxacin Drug Delivery; Kinetic of Adsorption and Releasing
...Show More Authors

Mesoporous silica (MPS) nanoparticle was prepared as carriers for drug delivery systems by sol–gel method from sodium silicate as inexpensive precursor of silica and Cocamidopropyl betaine (CABP) as template. The silica particles were characterized by SEM, TEM, AFM, XRD, and N2adsorption–desorption isotherms. The results show that the MPS particle in the nanorange (40-80 nm ) with average diameter equal to 62.15 nm has  rods particle morphology, specific surface area is 1096.122 m2/g, pore volume 0.900 cm3/g, with average pore diameter 2.902 nm, which can serve as efficient carriers for drugs. The adsorption kinetic of Ciprofloxacin (CIP) drug was studied and the data were analyzed and found to match well with

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Jun 20 2025
Journal Name
Baghdad Science Journal
The Role of Fear and Predator Dependent Refuge on a Stage Structure Prey-Predator System
...Show More Authors

The present paper investigates the role of fear and predator dependent refuge in the prey-predator system. The system describes the interaction between prey and a stage structure of predator that incorporates Holling II functional response. The predator splits into two compartments immature (juvenile) and mature (adult). The mature predators can hunt and reproduce but this capability is not found in the immature predators, the immature depend on their parents. The growth rate of prey decreases due to the existence of mature predators. The existence, uniqueness, and boundedness of the solution of the system are investigated. Three equilibrium points of the system are determined. The local stability of the system is studied. The global stabil

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Performance of Solar Adsorption Cooling System Using Methanol and Activated Carbon as a Working Pair
...Show More Authors

The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Engineering
Improving the Direction of Arrival Estimation Using the Parasitic Subspace Generated by Active-Parasitic Antenna (APA) Arrays
...Show More Authors

The improvement in Direction of Arrival (DOA) estimation when the received signals impinge on Active-Parasitic Antenna (APA) arrays will be studied in this work. An APA array consists of several active antennas; others are parasitic antennas. The responses to the received signals are measured at the loaded terminals of the active element. The terminals of the parasitic element are shorted. The effect of the received signals on the parasites, i.e., the induced short-circuit current, is mutually coupled to the active elements. Eigen decomposition of the covariance matrix of the measurements of the APA array generates a third subspace in addition to the traditional signal and noise subspaces generated by the all-active ante

... Show More
View Publication Preview PDF
Crossref