Preferred Language
Articles
/
7xc3kpIBVTCNdQwCSrdB
Preparation, <i>In-vitro, Ex-vivo</i>, and Pharmacokinetic Study of Lasmiditan as Intranasal Nanoemulsion-based <i>In Situ</i> Gel
...Show More Authors
Background:

Lasmiditan (LAS) is a recently developed antimigraine drug and was approved in October, 2019 for the treatment of acute migraines; however, it suffers from low oral bioavailability, which is around 40%.

Objective:

This study aimed to improve the LAS bioavailability via formulation as nanoemulsionbased in situ gel (NEIG) given intranasally and then compare the traditional aqueous-LASsuspension (AQS) with the two successful intranasal prepared formulations (NEIG 2 and NEIG 5) in order to determine its relative bioavailability (F-relative) via using rabbits.

Method:

Two successfully prepared nanoemulsion (NE) formulas, a and b, were selected for the incorporation of different percentages of pH-sensitive in situ gelling polymer (Carbopol 934) to prepare NEIGs 1, 2, 3, 4, 5, and 6. The pH, gelation capacity, gel strength, and viscosity were predicted for the prepared NEIGs. The release (in vitro) and the nasal permeation (ex vivo) were determined for NEIG 2 and 5, and then both were subjected to pharmacokinetics in vivo studies. Eighteen male rabbits weighing 2.0 to 2.5 kg were employed in the parallel design study. The body surface area (BSA) normalization method was applied for LAS dose calculation. Serial blood samples were taken out and subjected to drug analysis using the HPLC method previously developed and validated by Kumar et al. Primary pharmacokinetics parameters, including maximum drug concentration in plasma (Cmax), time to reach C-max (T-max), and area under the concentration-time curve from time zero to affinity (AUCt0-∞) were calculated. Both NE (a and b), together with NEIG (2 and 5) formulas, were subjected to the stability study. Finally, a nasal ciliotoxicity study was carried out to evaluate the nasal toxicity of developed NEIGs 2 and 5.

Result:

The results showed that NEIGs 2 and 5 could be selected as the optimized NEIGs as both achieved 100% permeation within 20 min and then released within 25 and 35 min, respectively, thus achieving 3.3 folds with higher permeation percentages as compared to the AQS. Both NEIGs 2 and 5 exerted comparable release and permeation values as the corresponding NE a and b with more residence time in order to overcome the normal nasal physiological clearance. The values of C-max, Tmax, and AUC0- ∞ for NEIG 2 and NEIG 5 were 8066 ± 242 ng/ml, 0.75 ± 0.05 h, 19616.86 ± 589 ng. h/ml, and 7975.67 ± 239 ng/ml, 1.0 ± 0.05 h, 17912.36 ± 537 ng. h/ml, respectively, compared to the traditional AQS, which is equal to 4181.09 ± 125 ng/ml, 2 ± 0.2 h, and 8852.27 ± 266 ng. h/ml, respectively. It was discovered that NEIGs 2 and 5 had better intranasal delivery of LAS and could significantly (p < 0.05) achieve a higher value of permeability coefficient (3.3 folds) and 2.5 folds improvement in bioavailability when compared to AQS. The NE a, NE b, NEIG2, and NEIG5 formulations showed good stability at various temperatures. According to the nasal ciliotoxicity study, the nasal mucosal membrane, which was treated with NEIG 5, showed irritation with a bit of damage. However, damage was not observed when it was treated with NEIG 2, indicating the biocompatibility of the last one to be selected as the optimum formula.

Conclusion:

NEIG 2 and NEIG 5 are promising new intranasal formulas with a faster onset of action and greater bioavailability than the oral dosage form (AQS). Finally, the selected optimum gold formula that will be ready for further clinical study is NEIG 2.

Scopus Crossref
View Publication
Publication Date
Thu Mar 05 2020
Journal Name
Revista Brasileira De Farmacognosia
Zerumbone-Loaded Nanostructured Lipid Carrier Gel Facilitates Wound Healing in Rats
...Show More Authors

View Publication
Scopus (22)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Sealing Depth of Q-Switched Nd:YAG 1064nm Laser in the Treatment of Patients with Hypersensitive Teeth: An In Vitro Study
...Show More Authors

The purpose of this work was to study the effects of the Nd:YAG laser on exposed dentinal
tubules of human extracted teeth using a scanning electron microscope (SEM). Eighty 2.5mm-thick
slices were cut at the cementoenamel junction from 20 extracted human teeth with an electric saw. A
diamond bur was used to remove the cementum layer to expose the dentinal tubules. Each slice was
sectioned into four equal quadrants and the specimens were randomly divided into four groups (A to D ).
Groups B to D were lased for 2 mins using an Nd:YAG laser at 6 pulses per second at energy outputs of
80 , 100 and 120 mJ. Group A served as control. Under SEM observation, nonlased specimens showed
numerous exposed dentinal tubules. SEM o

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the

... Show More
Crossref (1)
Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the therm

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Al–bahith Al–a'alami
The role of public relations in educating the Palestinian public about the issue of prisoners under the occupation An applied study on the employees of the Ministry of Detainees and Ex-Prisoners Affairs
...Show More Authors

The issue of Palestinian prisoners inside the prisons of the Israeli occupation is considered
a humanitarian issue par excellence، as it affects every Palestinian family as a
result of the absence of a husband، wife or son.
Almost no Palestinian house is vacant without one or more prisoners، and even women،
children and the elderly are not spared from these arrests.
The problem of the study was to identify the role of public relations in the Ministry
of Detainees and Ex-Prisoners Affairs in educating the Palestinian public about the
issue of prisoners، the nature of this role and the means used to bring support and
solidarity with this important and sensitive issue through the applied study on the
employee

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 25 2026
Journal Name
Journal Of Baghdad College Of Dentistry
A study to compare the efficiency of different instrumentation systems for cleaning oval-shaped root canals (An in vitro study)
...Show More Authors

Background: Proper cleaning and shaping of the whole root canal space have been recognized as a real challenge, particularly in oval-shaped canals.This in vitro study was conducted to evaluate and compare the efficiency of different instrumentation systems in removing of dentin debris at three thirds of oval-shaped root canals and to compare the percentage of remaining dentin debris among the three thirds for each instrumentation system. Materials and methods: Fifty freshly extracted human mandibular molars with single straight oval-shaped distal root canals were randomly divided into five groups of ten teeth each. Group One: instrumentation with ProTaper Universal hand instruments, Group Two: instrumentation with ProTaper Universal rotary

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
Crossref
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Statistical Equations to Estimate the In-situ Concrete Compressive Strength from Non-destructive Tests
...Show More Authors

The aim of this study is to propose reliable equations to estimate the in-situ concrete compressive strength from the non-destructive test. Three equations were proposed: the first equation considers the number of rebound hummer only, the second equation consider the ultrasonic pulse velocity only, and the third equation combines the number of rebound hummer and the ultrasonic pulse velocity. The proposed equations were derived from non-linear regression analysis and they were calibrated with the test results of 372 concrete specimens compiled from the literature. The performance of the proposed equations was tested by comparing their strength estimations with those of related existing equations from literature. Comparis

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Jan 25 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An in vitro evaluation of fit of the crowns fabricated by zirconium oxide-based ceramic CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles
...Show More Authors

Background: The objective of this in vitro study was to evaluate the vertical marginal fit of crowns fabricated with ZrO2 CAD/CAM, before and after porcelain firing cycles and after glaze cycles. Materials and Methods: An acrylic resin model of a left maxillary first molar was prepared and duplicated to have Nickel-Chromium master die. Ten die stone dies were sent to the CAD/CAM (Amann Girrbach) for crowns fabrication. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid buccal, mid palatal) before (Time 0) and after porcelain firing cycles (Time 1) and after glaze cycles (Time 2) using a light microscope at a magnification of ×100. One way ANOVA LSD tests were performed to determine wh

... Show More
View Publication Preview PDF