Preferred Language
Articles
/
7xc3kpIBVTCNdQwCSrdB
Preparation, <i>In-vitro, Ex-vivo</i>, and Pharmacokinetic Study of Lasmiditan as Intranasal Nanoemulsion-based <i>In Situ</i> Gel
...Show More Authors
Background:

Lasmiditan (LAS) is a recently developed antimigraine drug and was approved in October, 2019 for the treatment of acute migraines; however, it suffers from low oral bioavailability, which is around 40%.

Objective:

This study aimed to improve the LAS bioavailability via formulation as nanoemulsionbased in situ gel (NEIG) given intranasally and then compare the traditional aqueous-LASsuspension (AQS) with the two successful intranasal prepared formulations (NEIG 2 and NEIG 5) in order to determine its relative bioavailability (F-relative) via using rabbits.

Method:

Two successfully prepared nanoemulsion (NE) formulas, a and b, were selected for the incorporation of different percentages of pH-sensitive in situ gelling polymer (Carbopol 934) to prepare NEIGs 1, 2, 3, 4, 5, and 6. The pH, gelation capacity, gel strength, and viscosity were predicted for the prepared NEIGs. The release (in vitro) and the nasal permeation (ex vivo) were determined for NEIG 2 and 5, and then both were subjected to pharmacokinetics in vivo studies. Eighteen male rabbits weighing 2.0 to 2.5 kg were employed in the parallel design study. The body surface area (BSA) normalization method was applied for LAS dose calculation. Serial blood samples were taken out and subjected to drug analysis using the HPLC method previously developed and validated by Kumar et al. Primary pharmacokinetics parameters, including maximum drug concentration in plasma (Cmax), time to reach C-max (T-max), and area under the concentration-time curve from time zero to affinity (AUCt0-∞) were calculated. Both NE (a and b), together with NEIG (2 and 5) formulas, were subjected to the stability study. Finally, a nasal ciliotoxicity study was carried out to evaluate the nasal toxicity of developed NEIGs 2 and 5.

Result:

The results showed that NEIGs 2 and 5 could be selected as the optimized NEIGs as both achieved 100% permeation within 20 min and then released within 25 and 35 min, respectively, thus achieving 3.3 folds with higher permeation percentages as compared to the AQS. Both NEIGs 2 and 5 exerted comparable release and permeation values as the corresponding NE a and b with more residence time in order to overcome the normal nasal physiological clearance. The values of C-max, Tmax, and AUC0- ∞ for NEIG 2 and NEIG 5 were 8066 ± 242 ng/ml, 0.75 ± 0.05 h, 19616.86 ± 589 ng. h/ml, and 7975.67 ± 239 ng/ml, 1.0 ± 0.05 h, 17912.36 ± 537 ng. h/ml, respectively, compared to the traditional AQS, which is equal to 4181.09 ± 125 ng/ml, 2 ± 0.2 h, and 8852.27 ± 266 ng. h/ml, respectively. It was discovered that NEIGs 2 and 5 had better intranasal delivery of LAS and could significantly (p < 0.05) achieve a higher value of permeability coefficient (3.3 folds) and 2.5 folds improvement in bioavailability when compared to AQS. The NE a, NE b, NEIG2, and NEIG5 formulations showed good stability at various temperatures. According to the nasal ciliotoxicity study, the nasal mucosal membrane, which was treated with NEIG 5, showed irritation with a bit of damage. However, damage was not observed when it was treated with NEIG 2, indicating the biocompatibility of the last one to be selected as the optimum formula.

Conclusion:

NEIG 2 and NEIG 5 are promising new intranasal formulas with a faster onset of action and greater bioavailability than the oral dosage form (AQS). Finally, the selected optimum gold formula that will be ready for further clinical study is NEIG 2.

Scopus Crossref
View Publication
Publication Date
Fri May 01 2020
Journal Name
Journal Of Physics: Conference Series
The Product of Automorphic Weighted Composition Operators on Hardy Space H <sup>2</sup>
...Show More Authors
Abstract<p>Let <inline-formula> <tex-math><?CDATA $n\in {\mathbb{N}},{p}_{i}\in {\rm{U}},{\alpha }_{{P}_{i}}(z)=\frac{{p}_{i}-z}{1-{\bar{p}}_{i}z}(z\in {\rm{U}})$?></tex-math> <math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mrow> <mi>n</mi> <mo>∈</mo> <mi>ℕ</mi> <mo>,</mo> <msub> <mi>p</mi> <mi>i</mi> </msub></mrow></math></inline-formula></p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Viii. International Scientific Congress Of Pure, Applied And Technological Sciences (minar Congress)
DETERMINING AN APPROPRIATE INITIAL VALUE OF ECCENTRICITY FOR LOW EARTH SATELLITES USING EULER METHOD
...Show More Authors

The major goal of this research was to use the Euler method to determine the best starting value for eccentricity. Various heights were chosen for satellites that were affected by atmospheric drag. It was explained how to turn the position and velocity components into orbital elements. Also, Euler integration method was explained. The results indicated that the drag is deviated the satellite trajectory from a keplerian orbit. As a result, the Keplerian orbital elements alter throughout time. Additionally, the current analysis showed that Euler method could only be used for low Earth orbits between (100 and 500) km and very small eccentricity (e = 0.001).

View Publication Preview PDF
Crossref
Publication Date
Wed Dec 29 2021
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Magnetorheological Normally Close Directional Control Valve: Magnetorheological normally close directional control valve
...Show More Authors

This valve is intended for use in valves for steering movement, using the qualities of the Magneto-rheological (MR) fluid to regulate the fluid, direct contact without the utilization of moving parts like a spool, a connection between electric flux, and fluid power was made, The simulation was done to employ the" finite element method of magnetism (FEMM)" to arrive at the best design. This software is used for magnetic resonance valve finite element analysis. The valve's best performance was obtained by using a closed directional control valve in the normal state normally closed (NC) MR valve, with simulation results revealing the optimum magnetic flux density in the absence of a current and the shedding condition, as well as the optimum

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Non-Destructive Testing of Carbon Fiber Reinforced Magnetic Reactive Powder Concrete Containing Nano Silica
...Show More Authors

This study involves the design of 24 mixtures of fiber reinforced magnetic reactive powder concrete containing nano Silica. Tap water has been used in mixing 12 of these mixtures, while the other 12 have been mixed using magnetic water. Nano Silica (NS) with ratios (1, 1.5, 2, 2.5 and 3) % were used. The results showed that the mixture containing 2.5%NS gives the highest compressive strength at age 7 days. Many different other tests were carried out, the results showed that the fiber reinforced magnetic reactive powder concrete containing 2.5% NS (FRMRPCCNS)  has the higher bulk density, dynamic modulus of elasticity, ultrasonic pulse velocity  electrical resistivity and lesser absorption than fiber reinforced

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Field Programmable Gate Array (FPGA) Model of Intelligent Traffic Light System with Saving Power
...Show More Authors

In this paper, a FPGA model of intelligent traffic light system with power saving was built. The intelligent traffic light system consists of sensors placed on the side's ends of the intersection to sense the presence or absence of vehicles. This system reduces the waiting time when the traffic light is red, through the transition from traffic light state to the other state, when the first state spends a lot of time, because there are no more vehicles. The proposed system is built using VHDL, simulated using Xilinx ISE 9.2i package, and implemented using Spartan-3A XC3S700A FPGA kit. Implementation and Simulation behavioral model results show that the proposed intelligent traffic light system model satisfies the specified operational req

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
The Journal Of Immunology
Marijuana THC treatment led to decreased metabolic functions of Staphylococcal enterotoxin B-activated lymphocytes
...Show More Authors
Abstract<p>Studies from our laboratory have shown that Δ9-Tetrahydrocannabinol (THC), an ingredient found in marijuana plant Cannabis sativa, can attenuate acute lung injury induced by Staphylococcus enterotoxin B (SEB). In the current study, we investigated the role of THC on the metabolism of SEB-activated lymphocytes. To this end, we determined metabolic potential of SEB-activated lymphocytes treated with vehicle or THC by performing the Cell Mito Stress Test. The oxygen consumption rate (OCR) in THC-treated cells was decreased when compared to vehicle-treated group whereas the extracellular acidification rate (ECAR) was similar in both the groups. Specifically, electron transport chain inhi</p> ... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Plant Archive
Isolation of candida spp. From cancer patients who suffered oral candidiasis due to immunodeficiency
...Show More Authors

solation of candida spp. From cancer patients who suffered oral candidiasis due to immunodeficiency

Scopus (2)
Scopus
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Engineering
The Response of Reinforced Concrete Composite Beams Reinforced with Pultruded GFRP to Repeated Loads
...Show More Authors

This paper investigates the experimental response of composite reinforced concrete with GFRP and steel I-sections under limited cycles of repeated load. The practical work included testing four beams. A reference beam, two composite beams with pultruded GFRP I-sections, and a composite beam with a steel I-beam were subjected to repeated loading. The repeated loading test started by loading gradually up to a maximum of 75% of the ultimate static failure load for five loading and unloading cycles. After that, the specimens were reloaded gradually until failure. All test specimens were tested under a three-point load. Experimental results showed that the ductility index increased for the composite beams relative to the refe

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Viscosity Reduction of Sharqi Baghdad Heavy Crude Oil Using Different Polar Hydrocarbons, Oxygenated Solvents
...Show More Authors

This work studied the facilitation of the transportation of Sharqi Baghdad heavy crude oil characterized with high viscosity 51.6 cSt at 40 °C, low API 18.8, and high asphaltenes content 7.1 wt.%, by reducing its viscosity from break down asphaltene agglomerates using different types of hydrocarbon and oxygenated polar solvents such as toluene, methanol, mix xylenes, and reformate. The best results are obtained by using methanol because it owns a high efficiency to reduce viscosity of crude oil to 21.1 cSt at 40 °C. Toluene, xylenes and reformate decreased viscosity to 25.3, 27.5 and 28,4 cSt at 40 °C, respectively. Asphaltenes content decreased to 4.2 wt. % by using toluene at 110 °C. And best improvement in API of the heavy crude o

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
A 980nm Diode Laser Clot Formation of the Rabbit’s Dental Sockets after Teeth Extraction
...Show More Authors

The aim of this research work is to evaluate the use of 980 nm diode laser in clotting the blood
in the bone socket after tooth extraction. The objective is to prevent possible clot dislodgement which is
a defect that may lead to possible infection. A number of rabbits were irradiated using 980nm CW mode
diode laser, 0.86W power output for 9s and 15s exposure time. The irradiated groups were studied
histopathologically in comparison with a control group. Results showed that laser photothermal
coagulation was of benefit in minimizing the possibility of the incidence of postoperative complications.
The formation of the clot reduces the possibility of bleeding and infection.

View Publication Preview PDF