Preferred Language
Articles
/
7xc3kpIBVTCNdQwCSrdB
Preparation, <i>In-vitro, Ex-vivo</i>, and Pharmacokinetic Study of Lasmiditan as Intranasal Nanoemulsion-based <i>In Situ</i> Gel
...Show More Authors
Background:

Lasmiditan (LAS) is a recently developed antimigraine drug and was approved in October, 2019 for the treatment of acute migraines; however, it suffers from low oral bioavailability, which is around 40%.

Objective:

This study aimed to improve the LAS bioavailability via formulation as nanoemulsionbased in situ gel (NEIG) given intranasally and then compare the traditional aqueous-LASsuspension (AQS) with the two successful intranasal prepared formulations (NEIG 2 and NEIG 5) in order to determine its relative bioavailability (F-relative) via using rabbits.

Method:

Two successfully prepared nanoemulsion (NE) formulas, a and b, were selected for the incorporation of different percentages of pH-sensitive in situ gelling polymer (Carbopol 934) to prepare NEIGs 1, 2, 3, 4, 5, and 6. The pH, gelation capacity, gel strength, and viscosity were predicted for the prepared NEIGs. The release (in vitro) and the nasal permeation (ex vivo) were determined for NEIG 2 and 5, and then both were subjected to pharmacokinetics in vivo studies. Eighteen male rabbits weighing 2.0 to 2.5 kg were employed in the parallel design study. The body surface area (BSA) normalization method was applied for LAS dose calculation. Serial blood samples were taken out and subjected to drug analysis using the HPLC method previously developed and validated by Kumar et al. Primary pharmacokinetics parameters, including maximum drug concentration in plasma (Cmax), time to reach C-max (T-max), and area under the concentration-time curve from time zero to affinity (AUCt0-∞) were calculated. Both NE (a and b), together with NEIG (2 and 5) formulas, were subjected to the stability study. Finally, a nasal ciliotoxicity study was carried out to evaluate the nasal toxicity of developed NEIGs 2 and 5.

Result:

The results showed that NEIGs 2 and 5 could be selected as the optimized NEIGs as both achieved 100% permeation within 20 min and then released within 25 and 35 min, respectively, thus achieving 3.3 folds with higher permeation percentages as compared to the AQS. Both NEIGs 2 and 5 exerted comparable release and permeation values as the corresponding NE a and b with more residence time in order to overcome the normal nasal physiological clearance. The values of C-max, Tmax, and AUC0- ∞ for NEIG 2 and NEIG 5 were 8066 ± 242 ng/ml, 0.75 ± 0.05 h, 19616.86 ± 589 ng. h/ml, and 7975.67 ± 239 ng/ml, 1.0 ± 0.05 h, 17912.36 ± 537 ng. h/ml, respectively, compared to the traditional AQS, which is equal to 4181.09 ± 125 ng/ml, 2 ± 0.2 h, and 8852.27 ± 266 ng. h/ml, respectively. It was discovered that NEIGs 2 and 5 had better intranasal delivery of LAS and could significantly (p < 0.05) achieve a higher value of permeability coefficient (3.3 folds) and 2.5 folds improvement in bioavailability when compared to AQS. The NE a, NE b, NEIG2, and NEIG5 formulations showed good stability at various temperatures. According to the nasal ciliotoxicity study, the nasal mucosal membrane, which was treated with NEIG 5, showed irritation with a bit of damage. However, damage was not observed when it was treated with NEIG 2, indicating the biocompatibility of the last one to be selected as the optimum formula.

Conclusion:

NEIG 2 and NEIG 5 are promising new intranasal formulas with a faster onset of action and greater bioavailability than the oral dosage form (AQS). Finally, the selected optimum gold formula that will be ready for further clinical study is NEIG 2.

Scopus Crossref
View Publication
Publication Date
Tue Jan 27 2026
Journal Name
Journal Of Engineering
Technological Analysis of Flat Surface Conditions by Magnetic Abrasive Finishing Method (MAF)
...Show More Authors

This study introduced the effect of using magnetic abrasive finishing method (MAF) for finishing flat surfaces. The results of experiment allow considering the MAF method as a perspective for finishing flat surfaces, forming optimum physical mechanical properties of surfaces layer, removing the defective layers and decreasing the height of micro irregularities. Study the characteristics which permit judgment parameters of surface quality after MAF method then comparative with grinding

View Publication
Publication Date
Fri Aug 02 2024
Journal Name
Engineering, Technology &amp; Applied Science Research
Contributory Factors related to the Tensile Strength of Hot Mix Asphalt Concrete
...Show More Authors

Tensile strength is a critical property of Hot Mix Asphalt (HMA) pavements and is closely related to distresses such as fatigue cracking. This study aims to evaluate methods for assessing fatigue cracking in Asphalt Concrete (AC) mixes. In order to achieve optimum density at different binder contents, the mixes were compressed using a gyratory compactor. Tensile strength was assessed using the Indirect Tensile (IDT) and Semi-Circular Bend (SCB) tests. The results showed that the tensile strength measured by the SCB test was consistently higher than that measured by the IDT test at 25 °C. In addition, the SCB test showed a stronger correlation between increasing binder content and tensile strength. For binder contents ranging from 4

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Dec 02 2018
Journal Name
Indian Journal Of Public Health Research & Development
A revised checklist of the blister beetles genera (Coleoptera, Meloidae) from Iraq
...Show More Authors

Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Dehydration of Ethanol Using Pervaporation Separation with Nanoporous Hydrophilic Silica Ceramic Membrane
...Show More Authors

The pervaporation using a commercial hydrophilic ceramic membrane supplied from PERVATECH was conducted. The dehydration of ethanol/ water system was used as a model for the pervaporation study. Pervaporation experiments of ethanol/water system were carried out in the temperature range of 303-343K, ethanol concentration in the feed 10-90 vol. % and the feed flow rate in the range of 0.5-10 L/min.  In this work, the effect of operation parameters on permeates fluxes as well as permeates separation factors have been studied. The Water flux is strongly dependent on the temperature; it increased with increasing in temperature, which in turn decreased the selectivity of membrane to water molecules.

In addition water flux was decr

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Continuous De-emulsification of Crude Oil Using Packed Column Under Various Conditions
...Show More Authors

This research dealt with desalting of East Baghdad crude oil using pellets of either anionic, PVC, quartz, PE, PP or
nonionic at different temperature ranging from 30 to 80 °C, pH from 6 to 8, time from 2 to 20 minutes, volume percent
washing water from 5 to 25% and fluid velocity from 0.5 to 0.8 m/s under voltage from 2 to 6 kV and / or using additives
such as alkyl benzene sulphonate or sodium stearate. The optimum conditions and materials were reported to remove
most of water from East Baghdad wet crude oil.

View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Investigating the quality of open street map roads data inside Baghdad city
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Flexural Behavior of Reinforced Concrete Beams Reinforced with 3D-Textile Composite Fiber
...Show More Authors

Normal concrete is weak against tensile strength, has low ductility, and also insignificant resistance to cracking. The addition of diverse types of fibers at specific proportions can enhance the mechanical properties as well as the durability of concrete. Discrete fiber commonly used, has many disadvantages such as balling the fiber, randomly distribution, and limitation of the Vf ratio used. Based on this vision, a new technic was discovered enhancing concrete by textile-fiber to avoid all the problems mentioned above. The main idea of this paper is the investigation of the mechanical properties of SCC, and SCM that cast with 3D AR-glass fabric having two different thicknesses (6, 10 mm), and different layers (1,2 laye

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 19 2010
Journal Name
Computer And Information Science
Quantitative Detection of Left Ventricular Wall Motion Abnormality by Two-Dimensional Echocardiography
...Show More Authors

Echocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 05 2023
Journal Name
International Journal Of Interactive Mobile Technologies (ijim)
Computer Literacy with Skills of Seeking for Information Electronically among University Students
...Show More Authors

Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design of six electrode Enzial electrostatic lens low aberrations for electron gun
...Show More Authors

A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.

View Publication Preview PDF
Crossref (1)
Crossref