Preferred Language
Articles
/
7kK2jZoBMeyNPGM3BM2C
Online column preconcentration for speciation and selective determination of Cr(III) in natural water samples using flow injection with chemiluminescence detection
...Show More Authors
Abstract<p>A simple, rapid, sensitive and inexpensive approach is described in this work based on a combination of solid‐phase extraction of 8‐hydroxyquinoline (8HQ), for speciation and preconcentration of Cr(III) and Cr(VI) in river water, and the direct determination of these species using a flow injection system with chemiluminescence detection (FI–CL) and a 4‐diethylamino phenyl hydrazine (DEAPH)–hydrogen peroxide system. At different pH, the two forms of chromium [Cr(III) and Cr(VI)] have different exchange capacities for 8HQ, therefore two columns were constructed; the pH of column 1 was adjusted to pH 3 for retaining Cr(III) and column 2 was adjusted to pH 1 for retaining of Cr(VI). The sorbed Cr(III) and Cr(VI) species were eluted from columns using 3.0 ml of 0.1 N of HCl and 3.0 ml of 0.1 N of NaOH, respectively. The flow injection–chemiluminescence (FI–CL) method is based on light emitted due to the oxidation of DEAPH by the H<sub>2</sub>O<sub>2</sub> in the presence of Cr(III), which catalyzes the reaction. The flow cell is a transparent coiled tube made from glass (2.0 × 4.0, inner and outer diameter) and located close to the photodetector. The flow parameters: flow rate, sample volume, flow cell length, and distance to the CL detector were studied and optimized. Under optimum flow conditions, the Cr(III) concentration can be determined over the range 5–350 μg L<sup>−1</sup> with a limit of detection of 1.2 μg L<sup>−1</sup>, as the Cr(III) concentration is proportional to the intensity of the CL signal. The relative standard deviations (%) for 10 and 50 μg L<sup>−1</sup> Cr(III) were 1.2% and 3.2%, respectively. The effects of Al(III), Cd(II), Zn(II), Hg(II), Pb(II), Co(II), Cu(II), Ni(II), Mn(II), Ca(II), and Fe(III) were investigated. The proposed method is highly selective and sensitive, enabling a rapid determination of the Cr(III) amount in the presence of other interfering metals. Finally, the FI–CL method was examined in five river water samples with excellent recoveries.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Competitive Stripping of Multi-Organic Pollutants from Contaminated Water in Bubble Column Semi-Batch
...Show More Authors

Air  stripping  for  removal  of  Trichloroethylene  (TCE),  Chloroform  (CF)  and  Dichloromethane (DCM) from water were studied in a bubble column (0.073 m inside dia. and 1.08 m height with several sampling ports). The contaminated water was prepared from deionized water and VOCs. The presence of VOCs in feed solution was single, binary or ternary components. They were diluted to the concentrations ranged between 50 mg/l to 250 mg/l. The experiments were carried out in batch experiments which regard the bubble column as stirred tank and only gas was bubbled through stationary liquid. In this case transient measurements of VOC concentration in the liquid phase and the measured concentra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraq Journal Of Market Research And Consumer Protection
DETECTION OF HEAVY METALS POLLUTION INTYPES OF MILK SAMPLES IN BAGHDAD MARKETS
...Show More Authors

View Publication
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Analytica Chimica Acta
A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry
...Show More Authors

The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column

... Show More
View Publication
Scopus (34)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Wed Oct 29 2025
Journal Name
Clean Energy Science And Technology
Edge-intelligent leak detection in water distribution systems using CatBoost: A sustainable solution for reducing infrastructure losses
...Show More Authors

Water supply networks are marred by serious risks of imperceptible pipeline leakage, posing ‎sustainability ‎and ‎performance ‎threats.  This article highlights the use of vibratory signal features to get around the drawbacks of traditional methods in a highly detailed framework for leak detection based on CatBoost. demonstrated excellent diagnostic performance and carried out a thorough test performance evaluation on five leakage configurations  . The expected system achieved an accuracy of 98.1% (variance (well within x/3% of expected):, beating traditional competitors such as Random Forest (97.3%) and Support Vector Machine (93.8%). ‎For example, the area under the receiver-operating characteristic curve was 0.995, in

... Show More
View Publication
Scopus (9)
Crossref (8)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Analytical And Bioanalytical Chemistry Research
Mutual Derivatization in the Determination of Dapsone and Thymol Using Cloud Point Extraction Followed by Spectrophotometric Detection
...Show More Authors

A procedure for the mutual derivatization and determination of thymol and Dapsone was developed and validated in this study. Dapsone was used as the derivatizing agent for the determination of thymol, and thymol was used as the derivatizing agent for the determination of Dapsone. An optimization study was performed for the derivatization reaction; i.e., the diazonium coupling reaction. Linear regression calibration plots for thymol and Dapsone in the direct reaction were constructed at 460 nm, within the concentration range of 0.3-7 μg ml-1 for thymol and 0.3-4 μg ml-1 for Dapsone, with limits of detection 0.086 and 0.053 μg ml-1, respectively. Corresponding plots for the cloud point extraction of thymol and Dapsone were constructed

... Show More
Scopus (4)
Scopus
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Water Flow Visualization And Velocity Measurement Using Hydrogen Bubble Generation Technique In Low Speed Open Channel
...Show More Authors

Visualization of water flow around different bluff bodies at different Reynolds number ranging (1505 - 2492) was realized by designing and building a test rig which contains an open channel capable to ensure water velocity range (4-8cm/s) in this channel. Hydrogen bubbles generated from the ionized water using DC power supply are visualized by a light source and photographed by a digital camera. Flow pattern around a circular disk of (3.6cm) diameter and (3mm) thickness, a sphere of (3.8cm) diameter and a cylinder of
(3.2cm) diameter and (10cm) length are studied qualitatively. Parameters of the vortex ring generated in the wake region of the disk and the separation angle of water stream lines from the surface of the sphere are plott

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Sep 08 2024
Journal Name
Al Rafidain Journal Of Engineering Sciences
Oscillating Heat Pipe Start-up and Flow Characteristics with Water as Working Fluid
...Show More Authors

Thermal management has grown more and more problematic as electronic components continue to get faster and smaller. One of the passive two-phase cooling systems are Oscillating heat pipe (OHP) that have the capacity to transmit a significant quantity of thermal energy across long distances. Oscillating heat pipe is a device that has the potential to satisfy this developing requirement. An investigation into the effects of orientation, filling ratio, and heat load on the initiation and characteristics of oscillatory motion, combining numerical simulations with experimental validation. A copper tube with a 2 mm inner diameter and a 2 mm wall thickness is used to fabricate the OHP. The condenser, evaporator, and adiabatic sections are

... Show More
View Publication
Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
...Show More Authors

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

View Publication Preview PDF
Crossref
Publication Date
Sat Mar 17 2012
Journal Name
Environmental Science And Pollution Research Volume
Equilibrium, kinetic, and thermodynamic biosorption of Pb(II), Cr(III), and Cd(II) ions by dead anaerobic biomass from synthetic wastewater
...Show More Authors

Purpose Heavy metals are toxic pollutants released into the environment as a result of different industrial activities. Biosorption of heavy metals from aqueous solutions is a new technology for the treatment of industrial wastewater. The aim of the present research is to highlight the basic biosorption theory to heavy metal removal. Materials and methods Heterogeneous cultures mostly dried anaerobic bacteria, yeast (fungi), and protozoa were used as low-cost material to remove metallic cations Pb(II), Cr(III), and Cd(II) from synthetic wastewater. Competitive biosorption of these metals was studied. Results The main biosorption mechanisms were complexation and physical adsorption onto natural active functional groups. It is observed that

... Show More
View Publication Preview PDF
Crossref (55)
Crossref
Publication Date
Tue Sep 27 2022
Journal Name
Al–bahith Al–a'alami
Guidelines for covering online surveys
...Show More Authors

Media and communication's research are varied in accordance to research approaches' variety which seeks to reach convergent social, psychological, political, economic, and technical point of views. Its main aim is to assimilate all the new variables in the communicative method, especially, social media sites research; concerning their methodology, tools and theories. It is due to their diverse - developed applications and their increased rates of public use becoming irreplaceable in our daily life. It is well reflected by their consequent impact on the the public beside their role in changing its views.

This clarifies the notable increase of scientific research that concern them manifesting the dialectical relations and interfere

... Show More
View Publication Preview PDF
Crossref