There continues to be a need for an in-situ sensor system to monitor the engine oil of internal combustion engines. Engine oil needs to be monitored for contaminants and depletion of additives. While various sensor systems have been designed and evaluated, there is still a need to develop and evaluate new sensing technologies. This study evaluated Terahertz time-domain spectroscopy (THz-TDS) for the identification and estimation of the glycol contamination of automotive engine oil. Glycol contamination is a result of a gasket or seal leak allowing coolant to enter an engine and mix with the engine oil. An engine oil intended for use in both diesel and gasoline engines was obtained. Fresh engine oil samples were contaminated with four levels of glycol (0 ppm, 150 ppm, 300 ppm, and 500 ppm). The samples were analyzed with THz-TDS and converted to frequency domain parameters of refractive index and absorption coefficient. While both parameters showed potential, the absorption coefficient had the best potential and was able to statistically discriminate among the four contamination levels.
There are many ways to communicate a story, one can tell it, sing it, act it, write it, film it and can draw it. Each form of storytelling has its unique characteristics that separate it from the other forms. These distinguishing characteristics of each form does not indicate the superiority of one form over the other, on the contrary, it indicates the human ability to be creative on many levels. As students of literature, only the written form of a story is taken into account. One reason for the negligence of other forms of storytelling might be that singing and filming a story is not related to literature. But there has been a form of storytelling that uses words along with pictures which eventually became a genre of novels called grap
... Show MoreObjectives To quantify the reproducibility of the drill calibration process in dynamic navigation guided placement of dental implants and to identify the human factors that could affect the precision of this process in order to improve the overall implant placement accuracy. Methods A set of six drills and four implants were calibrated by three operators following the standard calibration process of NaviDent® (ClaroNav Inc.). The reproducibility of the position of each tip of a drill or implant was calculated in relation to the pre-planned implants’ entry and apex positions. Intra- and inter-operator reliabilities were reported. The effects of the drill length and shape on the reproducibility of the calibration process were also investig
... Show MoreDrought is a natural phenomenon in many arid, semi-arid, or wet regions. This showed that no region worldwide is excluded from the occurrence of drought. Extreme droughts were caused by global weather warming and climate change. Therefore, it is essential to review the studies conducted on drought to use the recommendations made by the researchers on drought. The drought was classified into meteorological, agricultural, hydrological, and economic-social. In addition, researchers described the severity of the drought by using various indices which required different input data. The indices used by various researchers were the Joint Deficit Index (JDI), Effective Drought Index (EDI), Streamflow Drought Index (SDI), Sta
... Show MoreSpatial and frequency domain techniques have been adopted in this search. mean
value filter, median filter, gaussian filter. And adaptive technique consists of
duplicated two filters (median and gaussian) to enhance the noisy image. Different
block size of the filter as well as the sholding value have been tried to perform the
enhancement process.
A study of the emission spectra of isotopic for electronic states has been carried out. The energies of the vibration levels ( =0,1,..25) and the values of spectral lines R(J) and P(J) versus rotational quantum number (J=0,1..25). It was found that were an increase of the value of R(J) with the increase of the values of J was found while the value of P(J) decreases with decreasing of the values of J . It was found that corresponding to R(J) and P(J) the spectral line R(J) increases when the values of m increased.
In this study, the feasibility of Forward–Reverse osmosis processes was investigated for treating the oily wastewater. The first stage was applied forward osmosis process to recover pure water from oily wastewater. Sodium chloride (NaCl) and magnesium chloride (MgCl2) salts were used as draw solutions and the membrane that was used in forward osmosis (FO) process was cellulose triacetate (CTA) membrane. The operating parameters studied were: draw solution concentrations (0.25 – 0.75 M), oil concentration in feed solution (FS) (100-1000 ppm), the temperature of FS and draw solution (DS) (30 - 45 °C), pH of FS (4-10) and the flow rate of both DS and FS (20 - 60 l/h). It was found that the water flux and oil concentration in FS increas
... Show MoreNowadays, due to our everyday stress and current stressful lifestyle, the loss of items appears a frequent issue and may be very inconvenient. In this regard, until the IoT becomes part of everyday life, we can use the software as an efficient tool to assist a person's searching, verifying, and finding lost belongings. This paper presents an Android-based application that we proposed and implemented to help users find lost items. Utilizing this software will enable the subscriber to record his request to the relevant authority. In addition, a special section offers to insert a contact telephone number or email to communicate between the person who found the item and the person who lost it. During testing, among other services, the p
... Show MoreCopper Telluride Thin films of thickness 700nm and 900nm, prepared thin films using thermal evaporation on cleaned Si substrates kept at 300K under the vacuum about (4x10-5 ) mbar. The XRD analysis and (AFM) measurements use to study structure properties. The sensitivity (S) of the fabricated sensors to NO2 and H2 was measured at room temperature. The experimental relationship between S and thickness of the sensitive film was investigated, and higher S values were recorded for thicker sensors. Results showed that the best sensitivity was attributed to the Cu2Te film of 900 nm thickness at the H2 gas.