Motives: The research deals with the issue of urban sprawl on agricultural lands. It is an urban problem caused by rapid urbanization and poor planning. It is considered one problem that threatens cities with environmental and health disasters. It also threatens agricultural life and the green belt surrounding cities. Changes in urban sprawl on agricultural land are associated with complex processes that lead to multiple social, economic, political, and environmental risks and thus pose a threat and an obstacle to the sustainability of cities. Aim: The research aims to study and evaluate the reality of the city of Baghdad and the extent of its ability and flexibility to withstand the disaster of urban sprawl on agricultural lands. The research also the aim of this research to identify the gaps and the reasons that led to this disaster and reach solutions that may reduce this phenomenon that burdens the economy and the Iraqi people who suffer from difficult economic conditions. In addition to raising awareness about the effects of urban sprawl on agricultural lands and the environment, clarifying the role of participation and the limits of responsibility that can be entrusted to government and academic agencies at all levels, individually or collectively, to participate and find solutions to the risk of extensive urban sprawl. Results: In assessing the reality of the study area, the research relied on the city resilience scorecard, which the United Nations Office for Disaster Risk Reduction (UNDRR) and with the support of United States Agency for International Development (USAID) and the European Commission. Field surveys and the opinions of specialists were relied upon to study the reality of the city of Baghdad to determine the extent to which it was affected by the disaster of encroachment on agricultural lands. There are gaps between planning and contemporary challenges among the most important research findings. Planning is increasingly decoupled from the contemporary urban challenges associated with rapid urbanization. The results of the practical study showed that the division of land uses in the city of Baghdad is not deep and incomplete. Also, it is not regularly reviewed according to the map of the expected risks, including the state of urban sprawl on agricultural lands in the city. Consequently, the city’s inability to withstand the disaster resulting from urban sprawl and the problems that result from it in the environmental, health, or social aspects. Based on the results, the research reached a set of recommendations, including the need for continuous updating to detect urban sprawl on agricultural lands. This is done using the latest remote sensing data and taking quick precautions against these expansions, in addition to the importance of updating building controls and standards regularly (or periodically) to take the changing data and evidence about risks to enhance the city of Baghdad’s ability to withstand the disaster of the decline of agricultural lands.
This study presents an investigation about the effect of fire flame on the punching shear strength of hybrid fiber reinforced concrete flat plates. The main considered parameters are the fiber type (steel or glass) and the burning steady-state temperatures (500 and 600°C). A total of 9 half-scale flat plate specimens of dimensions 1500mm×1500mm×100mm and 1.5% fiber volume fraction were cast and divided into 3 groups. Each group consisted of 3 specimens that were identical to those in the other groups. The specimens of the second and the third groups were subjected to fire flame influence for 1 hour and steady-state temperature of 500 and 600°C respectively. Regarding the cooling process, water sprinkling was applied directly aft
... Show MoreThis research foxed on the effect of fire flame of different burning temperatures (300, 400 and 500)oC on the compressive strength of reactive powder concrete (RPC).The steady state duration of the burning test was (60)min. Local consuming material were used to mixed a RPC of compressive strength around (100) MPa. The tested specimens were reinforced by (3.0) cm hooked end steel fiber of (1100) MPa yield strength. Three steel fiber volume fraction were adopted in this study (0, 1.0and 1.5)% and two cooling process were included, gradual and sudden. It was concluding that increasing burning temperature decreases the residual compressive strength for RPC specimens of(0%) steel fiber volume fraction by (12.16, 19.46&24.49) and (18.20, 27.77 &3
... Show MoreIn today’s competitive environment, organizational efficiency and sustained growth are crucial for survival. The performance of an organization is intricately connected to strategic planning, prompting firms to gather and leverage competitive information for a competitive advantage. Senior managers, recognizing this, initiate actions accordingly. This study aims to investigate the relationship between foresight, vision, strategic partnerships, motivation, system thinking, and organizational performance. Data, gathered through a self-administered questionnaire from various textile units, were analysed using structural equation modelling (SEM). The findings indicate that sub-constructs of strategic intelligence positively impact organizatio
... Show MoreA new class of biologically active nanocomposites and modified polymers based on poly (vinyl alcohol) (PVA) with some organic compounds [II, IV, V and VI] were synthesized using silver nanoparticles (Ag-NPs). All compounds were synthesized using nucleophilic substitution interactions and characterized by FTIR, DSC and TGA. The biological activity of the modified polymers was evaluated against: gram (+) (staphylococcus aureus) and gram (-): (Es cherichia coli bacteria). Antimicrobial films are developed based on modified poly (vinyl alcohol) MPVA and Ag-NPs nanoparticles. The nanocomposites and modified polymers showed better antibacterial activities against Escherichia coli (Gram negative) than against Staphyloc
... Show MoreIn this paper synthesis and extensive investigation of the microstructural and optoelectronic properties of polyaniline (PANI), Multiwalled carbon nanotube (MWCNTs) and MWCNTs reinforced PANI composites is presented. MWCNTs- PANI composites have been deposited by spin coating on silicon wafer substrate. Fourier Transform Infrared Spectroscopy shows no difference between PANI and its composites. However a change in peaks shape and absorption intensity has been observed. A strong effect of the MWCNTs weight percentage on the PANI/MWCNTs composites has been demonstrated. It was find that the thermal stability improved with increasing MWCNTs content. The optical band gap of the PANI thin
AlO-doped ZnO nanocrystalline thin films from with nano crystallite size in the range (19-15 nm) were fabricated by pulsed laser deposition technique. The reduction of crystallite size by increasing of doping ratio shift the bandgap to IR region the optical band gap decreases in a consistent manner, from 3.21to 2.1 eV by increasing AlO doping ratio from 0 to 7wt% but then returns to grow up to 3.21 eV by a further increase the doping ratio. The bandgap increment obtained for 9% AlO dopant concentration can be clarified in terms of the Burstein–Moss effect whereas the aluminum donor atom increased the carrier's concentration which in turn shifts the Fermi level and widened the bandgap (blue-shift). The engineering of the bandgap by low
... Show MoreIn this study, the effect of the combination of micro steel fibers and additives (calcium hydroxide and sodium carbonate) on the size of cracks formation and healing them were investigated. This study aims to apply the use of self-healing phenomenon to repair cracks and to enhance the service life of the concrete structures. Micro steel fibers straight type were used in this research with 0.2% and 0.4% by volume of concrete. A weight of 20 and 30 kg/m3 of Ca(OH)2 and 2 and 3 kg/m3 of Na2CO3 were used as a partial cement replacement. The results confirm that the concrete cracks were significantly self-healed up to 30 days re-curing. Cracks width up to 0.2 mm were comp
... Show MoreThe current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w
... Show More