Abstract Ternary Silver Indium selenide Sulfur AgInSe1.8S0.2 in pure form and with a 0.2 ratio of Sulfur were fabricated via thermal evaporation under vacuum 3*10-6 torr on glasses substrates with a thickness of (550) nm. These films were investigated to understand their structural, optical, and Hall Characteristics. X-ray diffraction analysis was employed to examine the impact of varying Sulfur ratios on the structural properties. The results revealed that the AgInSe1.8S0.2 thin films in their pure form and with a 0.2 Sulfur ratio, both at room temperature and after annealing at 500 K, exhibited a polycrystalline nature with a tetragonal structure and a predominant orientation along the (112) plane, indicating an enhanced degree of crystallinity. The Atomic Force Microscopy (AFM) was utilized to explore how Sulfur affects roughness of surfaces and sampls Grain Size . Furthermore, optical parameters, such as the optical gap and absorption coefficient, were calculated to assess the influence of Sulfur on the optical properties of the AgInSe1.8S0.2 thin films. The UV/Visible measurements indicated a reduction in the energy band gap to 1.78 eV for AgInSe1.8S0.2 at 500 K, making these films potentially suitable for photovoltaic applications. These thin films exhibited donor characteristics, with an increase in electron concentration observed with higher Sulfur content and annealing temperature
Background: Nickel-titanium (NiTi) archwires have become increasingly popular because of their ability to release constant light forces, which are especially useful during initial alignment and leveling phase. The aim of the present study was to investigate and compare the load–deflection characteristics of four commercially available NiTi archwires. Materials and methods: 200 NiTi 0.014, 0.016, 0.018, 0.016x0.022 and 0.019x0.025-inch nickel–titanium archwires from four different manufacturers (3M, Ortho Technology, Jiscop and Astar) were tested. The load-deflection properties of these archwires were evaluated by a full arch bending test in both palatal and gingival directionsat 37°C temperature using a universal material t
... Show MoreForty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,
... Show MoreIt was aimed to understand the interleukin-4 (IL-4) role in etio-pathogenesis of rheumatoid arthritis (RA). Two approaches were adopted. In the first one, a quantitative expression of IL4 gene was assessed by reverse transcription-quantitative polymerase chain reaction (RT-qPCR), and such findings were correlated with some demographic, clinical and laboratory parameters, which included gender, duration of disease, disease activity score (DAS-28), rheumatoid factors (RFs), C-reactive protein (CRP) and anti-cyclic citrullinated peptide (ACCP) antibodies. In the second approach, a single nucleotide polymorphism (SNP) of IL4 gene (rs2243250) was inspected by DNA sequencing using specific primers. Fifty-one Iraqi RA patients (22 males and 29 fem
... Show MoreIn this study, performance characteristics such as power take off (PTO) power consumption, fuel consumption, fuel consumption for the unit field-unit product were determined at different working speeds with two different PTO applications (540 and 540E) in a single row disc type silage machine. In particular, the 540E PTO application greatly reduces fuel consumption for unit work. The best results in terms of hourly fuel consumption were achieved in 540E PTO application and V1 working speed. When the field - product fuel consumption is evaluated, the best results were obtained with the 540E PTO application at the V3 working speed. When an evaluation is made considering all the parameters, it is concluded that the 540E PTO application will p
... Show More