Preferred Language
Articles
/
6YbGo4YBIXToZYALuZuY
TETRACYCLINE ANTIBIOTIC REMOVAL FROM AQUEOUS SOLUTION USING CLADOPHORA AND SPIRULINA ALGAE BIOMASS
...Show More Authors

Cladophora and Spirulina algae biomass have been used for the removal of Tetracycline (TC) antibiotic from aqueous solution. Different operation conditions were varied in batch process, such as initial antibiotic concentration, different biomass dosage and type, contact time, agitation speed, and initial pH. The result showed that the maximum removal efficiencies by using 1.25 g/100 ml Cladophora and 0.5 g/100 ml Spirulina algae biomass were 95% and 94% respectively. At the optimum experimental condition of temperature 25°C, initial TC concentration 50 mg/l, contact time 2.5hr, agitation speed 200 rpm and pH 6.5. The characterization of Cladophora and Spirulina biomass by Fourier transform infrared (FTIR) indicates that the presence of functional groups of different components such as the Hydroxyl group (-OH), amides(N-H stretch) were responsible of surface adsorption processes. The isothermal study has been applied using Freundlich, Temkin, and Langmuir models. The data best fitted with the Langmuir model. Finally, The pseudo-second-order kinetic model was best fitted the kinetic data with a high coefficient of determination (R2< 0.97 and 0.99) when used Cladophora and Spirulina algae biomass, respectively. The study showed that both Cladophora and Spirulina algae were promising and economical biomass that could be used for a large scale bioreactor.

Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Separation of Lead (Pb2+) and Cadmium (Cd2+) from Single and Binary Salt Aqueous Solutions Using Nanofiltration Membranes
...Show More Authors

The present work reports on the performance of three types of nanofiltration membranes in the removal of highly polluting and toxic lead (Pb2+) and cadmium (Cd2+) from single and binary salt aqueous solutions simulating real wastewaters. The effect of the operating variables (pH (5.5-6.5), types of NF membrane and initial ions concentration (10-250 ppm)) on the separation process and water flux was investigated. It was observed that the rejection efficiency increased with increasing pH of solution and decreasing the initial metal ions concentrations. While the flux decreased with increasing pH of solution and increasing initial metal ions concentrations. The maximum rejection of lead and cadmium ion

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of operation conditions on Catalytic Oxidation of Phenol in Aqueous Solution
...Show More Authors

This work was conducted to study the oxidation of phenol in aqueous solution using copper based catalyst with zinc as promoter and different carrier, i.e. γ-Alumina and silica. These catalysts were prepared by impregnation method.
The effect of catalyst composition, pH (5.6-9), phenol to catalyst concentration ratio (2-0.5), air feed rate (30-50) ml/s, stirring speed (400-800) rpm, and temperature (80-100) °C were examined in order to find the best conditions for phenol conversion.
The best operating conditions which lead to maximum phenol conversion (73.1%) are : 7.5 pH, 4/6 phenol to catalyst concentration, 40 ml/s air feed rate, 600 rpm stirring speed, and 100 °C reaction temperature. The reaction involved an induction period

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 03 2012
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Viscosity and Density of Chrom Alum in Aqueous Poly (Ethylene Glycol) Solution at Different Temperature
...Show More Authors

Density data of alum chrom in water and in aqueous solution of poly (ethylene glycol) (1500) at different temperatures (288.15, 293.15, 298.15) k have been used to estimate the apparent molar volume (Vθ), limiting apparent molar volume (Vθ˚) experimental slope (Sv) and the second derivative of limiting partial molar volume [δ2 θ v° /δ T2] p .The viscosity data have been analyzed by means of Jones –Dole equation to obtain coefficient A, and Jones –Dole coefficient B, Free activation energy of activation per mole of solvent, Δμ10* solute, Δμ20* the activation enthalpy ΔH*,and entropy, ΔS*of activation of viscous flow. These results have been discussed in terms of solute –solvent interaction and making/breaking ability of so

... Show More
Preview PDF
Publication Date
Thu Sep 13 2012
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Density and Viscosity of Amino Acid Serine in aqueous dimethyl sulfoxide solution at deferent temperatures
...Show More Authors

Publication Date
Sun Feb 27 2022
Journal Name
Iranian Journal Of Ichthyology
Production of peptide antibiotic bacteriocin using banana peel media
...Show More Authors

Many strains of lactic bacteria produce antimicrobial peptides of bacteriocins that are antibiotics used against pathogenic strains. The present work aimed to use a banana peels medium in the fermentation process to replace the commercial MRS medium for decreasing the cost of bacteriocins LAB production. Based on the result, banana peel was a cost-effective and viable alternative carbon source for the production and development of bacteriocin-producing Lactobacilli. The growth of lactobacilli in commercial MRS medium and Banana Peel medium showed no differences, therefore banana peel waste can be used to produce Lactobacilli bacteriocins. Lactobacillus strains grew exceptionally well at 37 C and pH 6.0.

View Publication Preview PDF
Scopus (1)
Scopus
Publication Date
Sat Apr 01 2023
Journal Name
Heliyon
Role of immobilised Chlorophyta algae in form of calcium alginate beads for the removal of phenol: isotherm, kinetic and thermodynamic study
...Show More Authors

View Publication
Scopus (16)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Sep 21 2022
Journal Name
Biochemical And Cellular Archives
ANTIBIOTIC SUSCEPTIBILITY AND BIOFILM FORMATION OF PSEUDOMONAS AERUGINOSA ISOLATED FROM CLINICAL AND ENVIRONMENTAL HOSPITAL SAMPLES
...Show More Authors

Pseudomonas aeruginosa is a Gram-negative opportunistic pathogen and a model bacterium for studying virulence and bacterial social traits. While it can be isolated in low numbers from a wide variety of environments including soil and water, it can readily be found in almost any human/animal-impacted environment. It is a major cause of illness and death in humans with immunosuppressive and chronic conditions, and infections in these patients are difficult to treat due to a number of antibiotic resistance mechanisms and the organism’s propensity to form multicellular biofilms. One hundred twenty clinical samples and forty hospital environmental samples (various sources) were collected from hospitals in Baghdad city during the period from Oc

... Show More
Publication Date
Thu Jul 24 2025
Journal Name
Desalination And Water Treatment
Removal of lead, cadmium, and copper from wastewater using Cinnamon bark waste to introduce it as a value-added product: Removal, kinetics and thermodynamics study
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
University Of Bucharest Rom Biotechnol Printed In Romania.
Antibiotic resistance determinants of Acinetobacter baumannii strains isolated from nosocomial infections
...Show More Authors

Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Ni(II), Pb(II), and Cu(II) from Industrial Wastewater by Using NF Membrane
...Show More Authors

This article reviews the technical applicability of nanofiltration membrane process for the removal of nickel, lead, and copper ions from industrial wastewater.

Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50, 100, 150 and 200 ppm), under different pressures (1, 2, 3 and 4 bar), temperatures (10, 20, 30 and 40 oC), pH (2, 3, 4, 5 and 5.5), and flow rates (1, 2, 3 and 4 L/hr), were prepared and subjected treated by NF systems in the laboratory. Suitable NF membrane was chosen after testing a number of NF membranes (University of Technology-Baghdad), in terms of production and removal. NF system was capable of removing more than (85%, 78%, and 66% for Ni(II

... Show More
View Publication Preview PDF