Preferred Language
Articles
/
6YYCtoYBIXToZYAL8bJJ
Evaluation of T-Shaped Fins With a Novel Layout for Improved Melting in a Triple-Tube Heat Storage System
...Show More Authors

The effects of T-shaped fins on the improvement of phase change materials (PCM) melting are numerically investigated in vertical triple-tube storage containment. The PCM is held in the middle pipe of a triple-pipe heat exchanger while the heat transfer fluid flows through the internal and external pipes. The dimension effects of the T-shaped fins on the melting process of the PCM are investigated to determine the optimum case. Results indicate that while using T-shaped fins improves the melting performance of the PCM, the improvement potential is mainly governed by the fin’s body rather than the head. Hence, the proposed T-shaped fin did not noticeably improve melting at the bottom of the PCM domain; additionally, a flat fin is added to the optimal case (Added-Fin case) and compared to the No-Fin, Uniform-Fin, and Optimum T-shaped Fin cases (no added fin). The analysis shows that the total heat storage rate of the Added-Fin case increased by 141.7%, 58.8%, and 47.6% compared with the No-Fin, Uniform-Fin, and the Optimum T-shaped Fin cases, respectively. Furthermore, the total melting time for the Added-Fin case was 1882 s and decreased by 59.6%, 38.4%, and 33.6% compared with those of the No-Fin, Uniform-Fin, and the Optimum T-shaped Fin (Optimum) cases, respectively.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
A GENERAL VELOCITY PROFILE FOR A LAMINAR BOUNDARY LAYER OVER FLAT PLATE WITH ZERO INCIDENCE
...Show More Authors

A general velocity profile for a laminar flow over a flat plate with zero incidence is obtained by employing a new boundary condition to the other available boundary conditions. The general velocity profile is mathematically simple and nearest to the exact solution. Also other related values, boundary layer thickness, displacement thickness, momentum thickness and coefficient of friction are nearest to the exact solution compared with other corresponding values for other researchers.

View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
A GENERAL VELOCITY PROFILE FOR A LAMINAR BOUNDARY LAYER OVER FLAT PLATE WITH ZERO INCIDENCE
...Show More Authors

A general velocity profile for a laminar flow over a flat plate with zero incidence is obtained by employing a new boundary condition to the other available boundary conditions. The general velocity profile is mathematically simple and nearest to the exact solution. Also other related values, boundary layer thickness, displacement thickness, momentum thickness and coefficient of friction are nearest to the exact solution compared with other corresponding values for other researchers.

View Publication Preview PDF
Crossref
Publication Date
Thu Jan 21 2010
Journal Name
Iraqi Journal Of Veterinary Medicine
Production and Partial Purification of Heat-Stable Enterotoxin (A) Produced by Enterotoxigenic Escherichia coli
...Show More Authors

A total of (25) stool samples were collected from children and adults (2- 4) years old suffering from diarrhea to isolate E. coli strains that produce heat-stable enterotoxin a (STa), and after performing microscopic examination, cultural characterization and biochemical identification only (11) isolates showed positive E. coli. STa activity was estimated by using suckling mouse assay (SMA) and from these (11) isolates only (5) showed STa activity and the one with the highest STa activity was selected for large scale production of STa, which was followed by partial purification using ion-exchange chromatography (normal phase) using DEAE sephadex A-50 column. After purification and determination of protein concentration by using the standard

... Show More
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Adenoidectomy with Myringotomy and Tympanostomy Tube Versus Adenoidectomy with Myringotomy in Treatment of Otitis Media with Effusion in 5-7 Years Old Children
...Show More Authors

Background: Adenoiditis is a common cause of otitis media with effusion (OME) in children & perhaps OME is one of the most common diseases leads to hearing impairment in children with subsequent impairment of speech development & learning difficulties , however, treatment remains controversial. Objectives: To evaluate if there is a significant advantage of tympanostomy tube insertion in association with adenoidectomy over adenoidectomy in association with myringotomy alone in treatment of children with OMEType of the study: This is a prospective study. Patients & methods: The study consisted from 63 children diagnosed as cases of bilateral OME & variable degrees of adenoid hypertrophy. The patients were divided randomly i

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Applied Energy
Novel mathematical modeling, performance analysis, and design charts for the typical hybrid photovoltaic/phase-change material (PV/PCM) system
...Show More Authors

Scopus (39)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Applied Energy
Novel mathematical modeling, performance analysis, and design charts for the typical hybrid photovoltaic/phase-change material (PV/PCM) system
...Show More Authors

View Publication
Publication Date
Fri Mar 25 2022
Journal Name
Asian Journal Of Biochemistry, Genetics And Molecular Biology
Evaluation of the Simple Sequence Repeats to Work as a Phase Variation with the Neisseria meningitidis Genome
...Show More Authors

Background: The most crucial mechanism of genetic variation in N. meningitidis is the slipped strand mispairing, this mechanism generates Phase variation using simple sequence repeat (SSR) and is commonly used by the N. meningitidis to escape the immune system despite its function in eradicating the pathogenic and commensal bacteria. Some of simple sequence repeats (SSRs) that located within the genome works as phase variation while other SSRs have no role in generating phase variation mechanisms. Therefore, Aim: the main goal of the current in silico study was to detect the probability of SSR to enroll with phase variation for the entire N. meningitidis genome. Methods: Different criteria were used to judge SSR as

... Show More
View Publication
Crossref
Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Heat Transfer in Bubble Column Contactors with immersed Coiled Heater
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Aug 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Design a Security Network System against Internet Worms
...Show More Authors

 Active worms have posed a major security threat to the Internet, and many research efforts have focused on them. This paper is interested in internet worm that spreads via TCP, which accounts for the majority of internet traffic. It presents an approach that use a hybrid solution between two detection algorithms: behavior base detection and signature base detection to have the features of each of them. The aim of this study is to have a good solution of detecting worm and stealthy worm with the feature of the speed. This proposal was designed in distributed collaborative scheme based on the small-world network model to effectively improve the system performance.

View Publication Preview PDF
Publication Date
Thu Mar 10 2022
Journal Name
Oral Surgery
Evaluation of buffered local anaesthesia in dental extraction: A randomized controlled study
...Show More Authors

Buffering of Local anaesthesia (LA) has been suggested as a mechanism to improve injection comfort and hasten the onset of anaesthesia. Aim This study aimed to evaluate the effectiveness of buffered LA in the extraction of maxillary premolars and molars. Materials and Methods This randomized controlled study included 100 patients who were indicated for extraction of maxillary posterior teeth, they were randomly divided into two groups; a study group that received infiltration of buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA, and a control group that received non-buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA. The buffering was performed using the Onset® LA buffering system (Onpharma®). The outcome va

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Crossref