Preferred Language
Articles
/
6Rj7XpgBVTCNdQwCMLtN
Manufacturing and Testing a Double Action Feed Pellet Durability Measuring Device
...Show More Authors
Abstract<p>The experiment was aimed to evaluate a locally manufactured a dual-action device used for measuring feed pellets durability. The device performs dropping process in conventional devices, then sifting process to separate the pellets from the crumbles simultaneously, with a control the motor speed by using the pulse width modulation (PWM) Technique. The device performance was compared with the durability measuring device of a moving drop box. Rotational speed, diameter of the die holes of the machine was used in this study. The results showed that increasing the rotational speed of the die from 280 to 300 and to 320 rpm, increasing the die holes diameter from 3 to 4 and to 5 mm, led to a significant decrease in the feed pellets durability, for both devices. The lowest die speed of 280 rpm, the minimum diameter of the die holes of 3 mm, recorded the highest pellets durability of 94.45% with the test speed of 33 rpm for the dual action measuring device as well as 93.45% for the movable drop box device. A highly significant correlation was found between data of the both devices. Test device success was proven for measure feed pellets durability.</p>
Scopus Crossref
View Publication
Publication Date
Wed Nov 22 2017
Journal Name
Farm Machinery And Processes Management In Sustainable Agriculture, Ix International Scientific Symposium
TESTING THE UNIFORMITY OF SPRAY DISTRIBUTION UNDER DIFFERENT APPLICATION PARAMETERS
...Show More Authors

View Publication
Crossref (4)
Clarivate Crossref
Publication Date
Wed Mar 28 2018
Journal Name
Indian Journal Of Natural Sciences
Detection of the Main Mycotoxins in Feed of Horses in Al-Zawra'a Park and Study their Effects on Hematological Feature
...Show More Authors

Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Journal Of Optical Technology
Random signal generation and synchronization in lab-scale measurement device independent–quantum key distribution systems
...Show More Authors

In this paper, a random transistor-transistor logic signal generator and a synchronization circuit are designed and implemented in lab-scale measurement device independent–quantum key distribution systems. The random operation of the weak coherent sources and the system’s synchronization signals were tested by a time to digital convertor.

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Manufacturing not sensitive Okougl Omaid poly Funnell alcohol suitable for technical
...Show More Authors

A sensitive film was manufactured Holokravaa using plastic materials the a Akougl substantive Amaid with poly alcohol Funnell addition to sensitive material Daakromat ammonium were obtained registry Qakma to diffraction efficiency of 83%

View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The priority of government investment for companies manufacturing sector in Iraq
...Show More Authors

The study aimed at clarifying the contradictions of the general industrial companies despite the investment allocations and the government investment expenditure on manufacturing activities under the so- called rehabilitation programs. However, this did not contribute to a certain extent in the growth and industrial leap in the direction of developing the activities of the sector Industrial sector in Iraq because of the lack of adoption of a number of basic principles towards the need to take priority of investment in the field of manufacturing and industrial decision-making in the restructuring of industry according to the priorities of investment in light of the international industrial trend, Tosmarah available to the manufact

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 31 2023
Journal Name
College Of Islamic Sciences
The concept of inconsistency and measuring the inverse relationship between overlap and contrast.
...Show More Authors

 

abstract:

The aim of this study is to clarify the relationship between the concept of  inconsistency and the measurement of the inverse relationship of overlap and contrast. The study will address the following points:

  1. Explaining the true nature of inconsistency and contrast, as understanding their relationship is essential for determining them.
  2. Examining the view of the scholars regarding their significance as approaches to understanding the relationship.
  • Identifying the relationship between inconsistency and contrast in terms of overlap and contrast.

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
Practical mathematical skills required for measuring and joining electrical circuits series and parallel
...Show More Authors

Skills learning is considered as an important factor in learning any subject as well as mathematics . Mathematical skills have a number of steps that should be learned and understood faster and with more accuracy . The practical or applied skills are type of learning which includes educational preparation and hand on skills is acquired which conducted by organized educational institutions. The sample included (120) students (males and females) first year / dept.of electrical technigues . The mathematical skills are implemented to wire up the electrical circuts. Test is implemented with questions concerned with the skills .statistical operations were conducted as well as the validity and standard deviation for the test .The results showed

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study and Analysis of Concentric Shell and Double Tube Heat Exchanger Using Tio2 Nanofluid
...Show More Authors

In this paper, nanofluid of TiO2/water of concentrations of 0.002% and 0.004% volume was used. This nanofluid was flowing through heat exchanger of shell and concentric double tubes with counter current flow to the hot oil. The thermal conductivity of nanofluid is enhanced with increasing concentrations of the TiO2, this increment was by 19% and 16.5% for 0.004% and 0.002% volume respectively relative to the base fluid (water). Also the heat transfer coefficient of the nanofluid is increased as Reynold's number and nanofluid concentrations increased too. The heat transfer coefficient is increased by 66% and 49% for 0.004% and 0.002% volume respectively relative to the base fluid. This study showed that the friction

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 05 2012
Journal Name
International Journal Of Scientific Research
The Influence of Parsley ( Petroselinum crispum ) as Feed Additive on Hematological Traits of Local Iraqi Geese
...Show More Authors

This study was conducted to investigate the effect of feeding diets containing different levels of parsley on the hematological traits of local Iraqi geese. A total of twenty-four local geese, one year old, were used in this experiment. The birds were allocated into four treatment groups, consisting of six geese each. Treatment groups were: control diet (C) (free from parsley); T1: control diet + 80 g/d parsley; T2: control diet + 160 g/d parsley; and T3: control diet + 240 g/d parsley. At the end of the experiment, blood samples were obtained from all geese from the brachial vein by venipuncture. Hematological traits included in this study were red blood cells count (RBC), hemoglobin concentration (Hb), packed cell volume (PCV), mean cell

... Show More
Preview PDF
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
The axial profile of plasma characteristics of cylindrical magnetron sputtering device
...Show More Authors

In the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the

... Show More
View Publication Preview PDF