Four samples were collected from the wastewater of State Battery Manufacturing Company (SBMC); Babylon 2 factory in AL-Waziriya district, as triplicates. Physical and chemical measurements were carried out such as temperature, pH, Lead concentrations and their ranges were: (19.5-34.5) °C, (6.1-6.4) and (4.5-6.5) mg/L, respectively. Six dominant Bacillus spp. isolates were isolated from these samples; namely, Bacillus subtilis N1, Bacillus subtilis N2, Bacillus subtilis N3, Bacillus cereus N4, Bacillus cereus N5 , Bacillus cereus N6. These isolates were capable of removing Lead from aqueous solutions in a capacity reached 27.6 ± 1.4, 10.1 ± 1.7, 74.5 ± 0.7, 8.93 ± 2.8, 8.1 ± 3.5, 1.6± 0.7 mg/L, respectively. Whereas cell walls,
... Show MoreRecent studies have proved the important role of fungi in the biodegradation of oil pollutants. The present study aims to find the optimal conditions for the fungi to get the best rate of the biodegradation of the polycyclic aromatic hydrocarbon (PAHs) (Naphthalene) compounds. Soil samples were taken from 18 different sites polluted with oil wastes and cultured then obtained 312 isolated fungi from 64 replicates Primarily screening were done on fungal isolates on solid media containing naphthalene the results revealed that 25 fungal isolates gave good growth, 47 fungal isolates gave Moderate growth, 66 gave weak growth and 147 fungal isolates gave no growth on Naphthalene solid media.
Then secondary screening were done on 25 fungal is
Background: Decreased thyroid hormone synthesis and low levels of circulating thyroid hormones result in clinical and biochemical changes in hypothyroidism. As
deficiency of thyroid hormones causes many metabolic processes to slow down, therefore; the maintenance of optimal health requires an adequate supply of
carbohydrates, proteins and lipids, and macronutrients, micronutrients, and trace elements.
Objective: Study the effect of the changing in serum level of the trace elements; Zn, Cu, Mn, and Se in hypothyroid patient.
Patients and Method: Thirty seven hypothyroid patients and fifteen normal healthy control persons were participated in this study. Serum zinc and copper were determined using
Trace elements concentrations are frequently reported to be a good indicator for diagnosis and prognosis of some disease. The levels of copper, zinc, manganese, and magnesium were measured in serum of two group. Group one contains (52) newborn jaundice patients while the second group contains (20) healthy newborn used as controls.
In this study the concentration of Cu, Zn, Mg, and Mn were measured using atomic absorption spectrophotometer (AAS). It has been found that zinc level is significantly lower in newborn jaundice patients compared with normal subjects at (p<0.05) , also the level of Cu, Mg, and Mn were significantly
... Show MoreBackground:
Copper (Cu) Zinc (Zn) and Magnesium (Mg) in serum, RBC, urine and dialyzate fluids were
studied in 39 patients, who have been undergoing chronic haemodialysis treatment. They were
divided in to polyuric , oliguric and anuric depending on their urinary output. Elevated serum and
RBC Mg was observed before dialysis, while decreased serum and RBC level was noticed except
serum Mg of polyuric patients. Before dialysis elevated serum and RBC Zn were observed. While
after dialysis these parameters were increased. Normal RBC Cu value before dialysis was observed.
While low serum Cu was noticed. After dialysis serum Cu showed raised value, while RBC level
decreased in oliguric and increased in polyuric patients. Zn / Cu rati
The current study included bioremoval of chromium metal ions from aqueous solution by using seventeen Pseudomonas aeruginosa species isolated from different environments. The experimental results showed that isolates Pseudomonas aeruginosa have high efficiency in removal of chromium where the P. aeruginosa p.8 was the most efficient (P≥0.001) in bioremoval of chromium with a removal capacity reached 92.5 mg/L and removal index reached (96.5%). While P. aeruginosa p.4 was the least efficient (P≥0.001) in bioremoval of chromium from aqueous solutions reached 74.6 mg/L and removal index reached (79.8%). The REP-PCR detection using BOX-primer, showed genetic relatedness among the isolates of P.aeru
... Show MoreRate of zinc consumption during the cathodic protection of copper pipeline which carries saline water was measured by weight loss technique in the absence and presence of bacteria. Variables studied were solution flow rate, temperature, time and NaCl concentration. It was found that within the present range of variables; the rate of zinc consumption increases with the increase of all operating conditions. The presence of bacteria increases the zinc consumption. Fourth order multi-term model and one-term model were suggested to represent the consumption data. Nonlinear regression analysis was used to estimate the coefficients of these models, while statistical analysis was used to determine the effect of each coefficient. Both models were re
... Show More