Preferred Language
Articles
/
6RbQAowBVTCNdQwCF_Xz
Determination the Wheat Weight and Volume: Mathematical Approach
...Show More Authors
Abstract<p>Grain size and shape are important yield indicators. A hint for reexamining the visual markers of grain weight can be found in the wheat grain width. A digital vernier caliper is used to measure length, width, and thickness. The data consisted of 1296 wheat grains, with measurements for each grain. In this data set, the average weight (We) of the twenty-four grains was measured and recorded. To determine measure of the length (L), width (W), thickness (T), weight (We), and volume(V). These features were manipulated to develop two mathematical models that were passed on to the multiple regression models. The results of the weight model demonstrated that the length and width of the grains were significantly different <italic>p < 0.0001</italic>. The coefficient of grain width was higher than that of grain length, indicating that grain width was more important than grain length. Furthermore, the overall model for volume was significantly different, (<italic>F</italic> <sub>(2,1295);</sub> =446832, <italic>p < 0.0001</italic>), regression(R<sup>2</sup>)-Square= 0.9986, Adj R-Sq=0.9986; and the RMSE of the experimental was RMSE=0.0002. The results of the weight model showed that the length, width, and thickness of the grains were significantly different <italic>p < 0.0001</italic>. The coefficient of grain the thickness was greater than the coefficient of grain length, indicating that the grain thickness was more significant than the grain length, and the coefficient of the grain width was more significant than the grain length. Moreover, the overall model for volume was significantly different (<italic>F</italic> <sub>(3,1295);</sub> =71809.6, <italic>p < 0.0001</italic>), regression (R<sup>2</sup>) and Adj-R-Sq = 0.9940 were equal, and RMES=0.3399. The introduced model may allow farmers to predict the weight and volume of wheat production during the wheat grain season, depending on the grain length, width, and thickness.</p>
Scopus Crossref
View Publication
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer
...Show More Authors

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 02 2024
Journal Name
Methods And Objects Of Chemical Analysis
Simultaneous Spectrophotometric Determination of Piroxicam, Naproxen, Diclofenac Sodium and Mefenamic Acid in Pharmaceutical Formulations by Partial Least Squares Method
...Show More Authors

A chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant

... Show More
View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Diyala Journal For Pure Science
Determination of IL-35, PTH, Ferritin and Other biochemical parameters in sera of Iraqi Men with chronic kidney failure.
...Show More Authors

Chronic kidney Failure, a progressive disease, includes both medical and biochemical features that damage kidneys and decrease their abilities to work effectively, this disease is characterized by a chronic disorders to both the innate and adaptive immune systems, generate a complex and not fully understood immune dysfunction. In the present study, (30) men suffering from chronic kidney failure with age in range (40-55) year and (30) healthy men within the same range of age were enrolled in this study. The aim of this study is to highlight the role of immunological aspect (IL-35), hormonal aspects (PTH), some functional proteins and immunological electrolytes in sera of chronic kidney failure (CKF) patients. Biochemical parameters were dete

... Show More
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
A New method for ISE construction for methyl orange dyes and using for indirect determination of Amitriptyline Hydrochloried drug
...Show More Authors

A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 31 2019
Journal Name
Journal Of Pure And Applied Microbiology
Determination of Level of 25-Hydroxy Vitamin D3 in Patients with Multiple Sclerosis and Its Effect on Disease Activity
...Show More Authors

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Water-Soluble Vitamins in Iraqi Honey Bee and Compare with Others Types by High –Performance Liquid Chromatography
...Show More Authors

High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu May 17 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified With Functionalized Graphene Oxide
...Show More Authors

  Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial ( GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration  of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Development of an Eco-Friendly Method for Iron Extraction and Determination in Pharmaceuticals Using Ciprofloxacin Drug as Chelating agent
...Show More Authors

A method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Apr 10 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified with Functionalized Graphene Oxide
...Show More Authors

Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial (GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration Γ of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket was obtained as 5.39×

... Show More
Preview PDF
Publication Date
Mon Jun 10 2019
Journal Name
Chemistry &chemical Technology
Quantitative Determination of Ephedrine Hydrochloride in Pharmaceutical Injections by Highly Sensitive Turbidimetric and Reversed-Phase Combined with UFLC Methods
...Show More Authors

In this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (13)
Scopus Clarivate Crossref