Preferred Language
Articles
/
64bNsoYBIXToZYAL_LEg
Residual strength and strengthening capacity of reinforced concrete columns subjected to fire exposure by numerical analysis
...Show More Authors
Abstract<p>This study is a numerical investigation of the performance of reinforced concrete (RC) columns after fire exposure. This study aims to investigate the effect of introducing lateral ties and using the RC jacket on improving post-fire behavior of these columns, the effect of the duration of the fire on ultimate load of columns. The analysis was performed through ABAQUS, a 3D – non-linear finite element program. 4 m tall lengthening square RC column with a cross- section of 0.4 m × 0.4 m was used as a test specimen. The RC column was reinforced by 4Ø28 mm longitudinal bars bonded by steel tie bars of Ø10 mm spaced at 400 mm. The firing temperature was increased to 600°C for 60 min. The results indicated that as the fire load duration increases, the load’s capacity diminishes. The effect of increasing the steel ratio of the RC column resulted in a decrease in the percentage of load reduction following combustion. It was concluded that strengthening columns by RC jackets is efficient and that the axial load capacity of reinforced columns was enhanced.</p>
Scopus Clarivate Crossref
Publication Date
Sat Nov 01 2025
Journal Name
Iop Conference Series: Earth And Environmental Science
Evaluation the Structural Behavior of Lightweight Concrete-Filled Steel Tube Columns: A Review
...Show More Authors
Abstract<p>Lightweight concrete-filled tube (CFST) columns offer numerous benefits, such as reduced weight, enhanced resistance to buckling, improved structural performance, and the ability to endure cyclic loading. This study considered key research on the structural behavior of CFST columns, covering various topics, including lightweight concrete, methods of concrete placement within steel tubes, and CFST columns with and without shear connectors. The literature review reveals that while several researchers have explored the use of shear connectors as a load-transfer mechanism in CFST columns, there is no consensus on the design methodology for connector resistance. Shear connectors signifi</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Impact and Transverse Strength of Denture Bases Repaired with Nano Reinforced Resin
...Show More Authors

Background: Failure of resin bases were a major disadvantage recorded in the constructed dentures. Reinforcements of the repair joint with nano fillers represent an attempt to enhance the strength and durability. The purpose of the research was to estimate the influence of nano fillers reinforcement with (ZrO2 and Al2O3) on impact and transverse strength of denture bases repaired with either cold or hot processing acrylic resin. Materials and methods: A hundred and forty (140) samples were processed with hot cured resin and organized in subgroups depending on the repair materials and condition (without repair (control), repair with hot cure, cold cure, hot and cold cure reinforced with either (5% Zr2O or 0.5% Al2O3). The samples in these

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Engineering, Technology & Applied Science Research
Castellated Beams with Fiber-Reinforced Lightweight Concrete Deck Slab as a Modified Choice for Composite Steel-Concrete Beams Affected by Harmonic Load
...Show More Authors

The behavior investigation of castellated beams with fiber-reinforced lightweight concrete deck slab as a modified choice for composite steel-concrete beams affected by harmonic load is presented in this study. The experimental program involved six fixed-supported castellated beams of 2140mm size. Three types of concrete were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber-Reinforced Aggregate Concrete (LWACF). The specimens were divided into two groups: the first comprised three specimens tested under harmonic load effect of 30Hz operation frequency for 3 days, then the residual strength was determined through static load application. The second group included three specimens ide

... Show More
Crossref (12)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Overview of seismic performance assessment of reinforced concrete buildings
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jul 28 2025
Journal Name
Structural Concrete
Behavior of axially loaded concrete composite columns encased with <scp>GFRP</scp> and steel I‐sections
...Show More Authors
Abstract<p>The aim of this investigation is to evaluate the experimental and numerical effectiveness of a new kind of composite column by using Glass Fiber‐Reinforced Polymer (GFRP) I‐section as well as steel I‐section in comparison to the typical reinforced concrete one. The experimental part included testing six composite columns categorized into two groups according to the slenderness ratio and tested under concentric axial load. Each group contains three specimens with the same dimensions and length, while different cross‐section configurations were used. Columns with reinforced concrete cross‐section (reference column), encased GFRP I‐section, and encased steel I‐section were adopted in each </p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Engineering
Laboratory Study on the Effect of Water-Cement Ratio on Strength Characteristics of Jet Grouting Columns
...Show More Authors

Jet grouting is one of the most widely applied soil improvement techniques. It is suitable for most geotechnical problems, including improving bearing capacity, decreasing settlement, forming seals, and stabilizing slopes. One of the difficulties faced by designers is determining the strength and geometry of elements created using this method. Jet grouted soil-cement columns in soil are a complicated issue because they are dependent on a number of parameters such as soil type, grout and water flow rate, rotation and lifting speed of monitor, nozzle jetting force, and water to cement ratio of slurry. This paper discusses the effect of the water-cement ratio on the physical and mechanical characteristics of soilcrete. In t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Materials Science And Engineering
Effect of magnetic water on strength properties of concrete
...Show More Authors
Abstract<p>The research’s main goal is to investigate the effects of using magnetic water in concrete mixes with regard to various mechanical properties such as compressive, flexural, and splitting tensile strength. The concrete mix investigated was designed to attain a specified cylinder compressive strength (30 MPa), with mix proportions of 1:1.8:2.68 cement to sand to crushed aggregate. The cement content was about 380 kg/m<sup>3</sup>, with a w/c ratio equal to 0.54, sand content of about 685 kg/m3, and gravel content of about 1,020 kg/m3. Magnetic water was prepared via passing ordinary water throughout a magnetic field with a magnetic intensity of 9,000 Gauss. The strength test</p> ... Show More
Crossref (6)
Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Bearing Capacity of a Strip Model Footing on Loose Sand Reinforced With Pomegranate Sticks Mat
...Show More Authors

A series of laboratory model tests has been carried out to investigate the using of pomegranate sticks mat as reinforcement to increase the bearing capacity of footing on loose sand. The influence of depth and length of pomegranate sticks layer was examined. In the present research single layer of pomegranate sticks reinforcement was used to strengthen the loose sand stratum beneath the strip footing. The dimensions of the used foundation were 4*20 cm. The reinforcement layer has been embedded at depth 2, 4 and 8 cm under surcharge stresses . Reinforcing layer with length of 8 and 16 cm were used. The final model test results indicated that the inclusion of pomegranate sticks reinforcement is very effective in improvement the loading cap

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
Effect of Petroleum Products on Steel Fiber Reinforced Concrete
...Show More Authors

This Investigation aims to study the effect of adding Steel fibers with different volume fractions Vf (o.5, 0.75, and 1% by volume of concrete) with aspect ratio 100 on mechanical properties of concrete, and also
finding the influence of petroleum products (Kerosene and Diesel) on mechanical properties of Steel Fiber Reinforced Concrete (SFRC).
The experimental work consists of two groups: group one consists of specimens (cubes and prisms) plain and concrete reinforced with steel fiber exposed to continuous curing with water. Group two consists of
specimens (cubes and prisms) plain and concrete reinforced with steel fiber exposed to kerosene and diesel after curing them in water for 28 days before exposure. The results of all te

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 01 2016
Journal Name
Journal Of Engineering
Torsional Resistance of Reinforced Concrete Girders with Web Openings
...Show More Authors
In this study, a three dimensional finite element analysis was utilized to study the behavior of reinforced concrete T-
girders with and without web openings under pure torsion by using
ANSYS
APDL
... Show More
View Publication Preview PDF