Excess heat significantly reduces the efficiency and lifespan of electrical and optoelectronic devices. While passive radiative cooling is becoming more common, achieving active thermal control without physical reconfiguration remains challenging. Unlike conventional static absorbers, we propose a broadband plasmonic solar absorber designed to regulate energy absorption in the near-infrared (NIR) region without modifying the geometrical parameters. The design utilizes a coaxial cylindrical metal-insulator-metal (MIM) configuration, combining refractory copper (Cu), silicon dioxide (SiO2), and a trilayer graphene (Gr) that allows electrical tuning in a broadband solar absorber. Simulation results show a maximum broadband absorption efficiency of 93.54% when the Gr Fermi level is set to 0.1 eV. By electrically modulating the Fermi level to 0.7 eV, the proposed structure exhibits good reflection characteristics in the NIR region, and the absorption is actively suppressed to 67.92%, thereby transitioning the device into a thermal-protection mode. Furthermore, thermal analysis confirms that this active modulation achieves a significant temperature reduction from 55.9 °C to 31 °C at a wavelength of 1100 nm. The structure also exhibits remarkable environmental robustness, including polarization insensitivity and angular stability up to 55°, owing to its symmetrical coaxial geometry. This study presents a compact absorber with a high-performance solution for dynamic sunlight harvesting and precision thermal management. The proposed work provides a versatile framework for next-generation solar cells and integrated optoelectronic systems.
This research study the effect of surface modification and copper (Cu) plating carbon fiber (CF) surface on the thermal stability and wettability of carbon fiber (CF)/epoxy (EP) composites. The TGA result indicates that the thermal-stability of carbon fiber may be enhanced after Cu coating CF. TGA curve showed that the treatment temperature was enhanced thermal stability of Ep/CF, this is due to the oxidation during heating. The Cu plating increased the thermal conductivity, this increase might be due to reduce in contact resistance at the interface due to chemical modification and copper plating and tunneling resistance.
The increase of surface polarity after coating cause decreas
... Show MoreThe thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and
... Show MoreThis work describes the weathering effects (UV-Irradiation, and Rain) on the thermal conductivity of PS, PMMA, PS/PMMA blend for packaging application. The samples were prepared by cast method at different ratios (10, 30, 50, 70, and 90 %wt). It was seen that the thermal conductivity of PMMA (0.145 W/m.K), and for PS(0.095 W/m.K), which increases by PS ratio increase up to 50% PS/PMMA blend then decreased that was attributed to increase in miscibility of the blend involved. By UV-weathering, it was seen that thermal conductivity for PMMA increased with UV-weathering up to (30hr) then decreased, that was attributed to rigidity and defect formation, respectively. For 30%PS/PMMA, there results showed unsystematic decrease in thermal conduct
... Show MoreThis paper numerically and theoretically investigates the optical and thermal performance of a parabolic trough collector PTC system. Many numerical simulations and theoretical analyses are conducted to demonstrate the influence of the receiver geometry and shifting from the focal position on the optical performance. The examined receiver geometries are circular, square, triangular, elliptical, and the new circular–square combined geometry is named as channel receiver. The thermal performance of PTC is examined for different volume flow rates theoretically in the range of (0.36 to 2.4 lpm). The results show that the best optical design is the channel receiver with an intercept factor of 84%, while the worst is the elliptical receiver with
... Show MoreThe study was carried out at field agriculture in Baghdad–Iraq in 2015. For purpose evaluated the performance the selected implements tillage, suitable tire pressure and speed tractor under silt clay loam to measured Effective field capacity, Actual Time for plowing One Donam ( hr), Appearance Tillage ( number of clods > 10 cm), Fuel consumption measure in two unit (L/Donam and L/hr) and Machinery Unit Energy Requirement ( kw.hr / Donam). Split – split plot design under randomized complete block design with three replications using Least Significant Design 5 % was used. Three factor used in this experiment included Two types of plows included Chisel and Disk plows which represented main plot, Three Tires Inflation Pressure was second fa
... Show MoreIn this paper, we propose an approach to estimate the induced potential, which is generated by swift heavy ions traversing a ZnO thin film, via an energy loss function (ELF). This induced potential is related to the projectile charge density, ρq(k) and is described by the extended Drude dielectric function. At zero momentum transfer, the resulting ELF exhibits good agreement with the previously reported results. The ELF, obtained by the extended Drude model, displays a realistic behavior over the Bethe ridge. It is observed that the induced potential relies on the heavy ion velocity and charge state q. Further, the numerical results show that the induced potential for neutral H, as projectile, dominates when the heavy ion velocity is less
... Show MoreThis study examines patterns of exposure of Iraqi university students to selective daily Iraqi newspapers and the motives of this exposure, as well as its associated factors that affect the average exposure. It tries to answer several questions, including those related to the levels of exposure of Iraqi university students to daily Iraqi newspapers and classification of patterns of selective exposure to daily Iraqi newspapers and the most prominent Iraqi daily newspapers that are selectively exposed by Iraqi university students. It also examines the motives of this selective exposure and factors that increase the degree of exposure to the daily Iraqi newspapers, and the most prominent stages in which Iraqi university students find their
... Show MoreThe dielectric properties of epoxy/palm oil fiber composites at different concentrations 1,3,5, and 10% by weight, and frequency ranging from 100 Hz to 1000kHz.Epoxy, zinc oxide and oil palm empty fruit bunch (OPEFB)fiber composites were prepared by hand –lay up into sheets. The effects of incorporated fibers on the electrical conductivity and thermal conductivity of the composites were investigated. The electrical conductivity of the composites decreased with increasing OPEFB fiber content. Despite the slight decrease in conductivity, the composites still sufficiently conductive relatively to applications such as sensors after the fiber addition, the thermal conductivity increased to 0.41
The solar photocatalytic degradation of diuron, which is one of the herbicides, has been studied by a solar pilot plant in heterogeneous solar photocatalysis with titanium dioxide. The pilot plant was made up of compound parabolic collectors specially designed for solar photocatalytic applications. The influence of different variables such as, H2O2 initial concentration, TiO2 initial concentration, and diuron initial concentration with their relationship to the degradation efficiency were studied. Hydrogen peroxide (H2O2) found to increase the rate of diuron degradation. The best removal efficiency of heterogeneous solar photocatalytic TiO2 system was found to be 46.65 % and for heterogeneous solar photocatalytic TiO2/ H2O2 system was fo
... Show MoreIn this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p
... Show More