Gypsum is one of the important construction materials in Iraq in plastering surfaces and gypsum board , the ability of gypsum to give a comfortable an aesthetic ambiance as a construction material increase the need of gypsum , The particle size , total surface area and particle size distribution were factors affecting plaster properties used for construction properties . In this study gypsum paste was used with different mixing ratios of particle size and studied the physical properties of these types of pastes named (standard consistency ,setting time ,density) and compressive strength . The results showed that the water to gypsum ratio increased with increasing the fineness of the gypsum to (0.75%) and the setting time to the maximum allowed according to the Iraqi standard (25 minute) when the distribution of particle size between (600-75) microns . Thus ,superplasticizer was used in more fine paste types .There is a direct relationship between setting time and the water to gypsum ratio ,but the setting time decreasing with increasing the fineness of the gypsum when the distribution of particle size between (300-75) microns. There is also a direct relationship between density and gypsum fineness . In terms of compressive resistance , it increases slightly when the particle size distribution is between (900-75) μm and increases significantly (40-42)% relatively to the reference paste with particle size distribution (300-75) μm and superplasticizer additive .Compression strength is also affected by the water to gypsum ratio ,there is an inverse relationship between them.
Abstract
The purpose of our study was to develop Dabigatran Etexilate loaded nanostructured lipid carriers (DE-NLCs) using Glyceryl monostearate and Oleic acid as lipid matrix, and to estimate the potential of the developed delivery system to improve oral absorption of low bioavailability drug, different Oleic acid ratios effect on particle size, zeta potential, entrapment efficiency and loading capacity were studied, the optimized DE-NLCs shows a particle size within the nanorange, the zeta potential (ZP) was 33.81±0.73mV with drug entrapment efficiency (EE%) of 92.42±2.31% and a loading capacity (DL%) of 7.69±0.17%. about 92% of drug was released in 24hr in a controlled manner, the ex-vivo intestinal p
... Show MoreDiabetes mellitus is a chronic illness that commonly leads to progressive and incapacitating of patients’ condition over the past 20 years.
The aim of the study was to evaluate the effects of the coughing technique, ShotBlockerTo evaluate the effects of the coughing technique, ShotBlocker and vibration device on pain intensity and patient satisfaction during subcutaneous (SC) insulin injections in hospitalised adults with Type 2 diabetes mellitus (T2DM).
This study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreThe study aims to evaluate sustainable traffic management strategies for congested intersections in medium-sized Iraqi cities, with a focus on Al-Sa’a Intersection and Al-Jari Street in Hit City. These nodes face severe traffic congestion, delays, and infrastructure limitations that compromise urban mobility and sustainability. A multi-criteria evaluation (MCE) framework was employed to analyze three categories of interventions—engineering, planning, and administrative—based on five weighted criteria: traffic efficiency (40%), delay reduction (25%), cost (20%), environmental impact (10%), and social acceptance (5%). The methodology combined field data collection (traffic counts, travel time, and delays), GIS-based spatial analysis, an
... Show More