Preferred Language
Articles
/
5hcrWZIBVTCNdQwC96wP
Smart Irrigation Technique in the Fixed Irrigation System Based on Soil Moisture Content
...Show More Authors
Abstract<p>The growing water demand has raised serious concerns about the future of irrigated agriculture in many parts all over the world, changing environmental conditions and shortage of water (especially in Iraq) have led to the need for a new system that efficiently manages the irrigation of crops. With the increasing population growing at a rapid pace, traditional agriculture will have a tough time meeting future food demands. Water availability and conservation are major concerns for farmers. The configuration of the smart irrigation system was designed based on data specific to the parameters concerning the characteristics of the plant and the properties of soil which are measured once in the research (permeability, pH, humidity, porosity, etc.), the soil moisture content sensors are placed in the root zone of plants when the crop needs to be irrigated the sensors send notifications to the user of the system from the application on a smartphone to operate the water pump and on the contrary when the soil saturated the sensors notify the user to turn off the water pump. This paper aims to discuss the aspects related to designing and fabricating an automatic irrigation system using sensors of soil moisture content using this method will save time and money significantly. The study found that the quantity of water consumed to irrigate the yellow corn crop in the portion assigned for smart irrigation technique in an area of 875 m<sup>2</sup> is less than the amount of consumed water utilized in the section allocated for fixed sprinkler irrigation in the same area by 34.444%, furthermore, the yield of the yellow corn crop grown using smart irrigation technique exceeds that of the crop grown by fixed sprinkler irrigation. And also, human intervention will be reduced.</p>
Scopus Crossref
View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Indian Journal Of Dental Research
Biomechanical finite element analysis of a single implant threaded in anterior and posterior regions of maxilla bone
...Show More Authors

Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two diff

... Show More
View Publication
Scopus (13)
Crossref (13)
Scopus Crossref
Publication Date
Fri May 01 2020
Journal Name
Journal Of Building Engineering
Technologies for safety and health management in construction: Current use, implementation benefits and limitations, and adoption barriers
...Show More Authors

View Publication
Scopus (246)
Crossref (196)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (6)
Scopus Crossref
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Detection of Epicatechin in Camellia sinensis Leaves by Thin Layer Chromatography and High Performance Liquid Chromatography Techniques
...Show More Authors

    The current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method) involved using three different solvents which are  absolute ethanol, 50% aqueous ethanol and water  for both extraction methods using room temperature and direct heat respectively. Crude extracts of two tea samples that obtained from two methods were fractionated by using two solvents with different polarity (chloroform and

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry &amp; Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
Scopus (23)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Tue Jul 01 2025
Journal Name
Journal Of Breast Diseases
Association Between Serum Interleukin-41 Levels and Breast Cancer Status: A Case–Control Study in Iraqi Women
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Organic &amp; Biomolecular Chemistry
Small-molecule anticancer agents kill cancer cells by harnessing reactive oxygen species in an iron-dependent manner
...Show More Authors

In the course of generating a library of open-chain epothilones, we discovered a new class of small molecule anticancer agents that has no effect on tubulin but instead kills selected cancer cell lines by harnessing reactive oxygen species in an iron-dependent manner.

View Publication
Scopus (12)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Moroccan Journal Of Chemistry
Corrosion Protection of Carbon Steel in seawater by alumina nanoparticles with poly (acrylic acid) as charging agent
...Show More Authors

Nanostructured Al2O3has been applied as a protective coating against corrosion of the carbon steel (C.S) in seawater environment (3.5% NaCl) at temperatures range (298-328)K. Aluminananoparticles were deposited on carbon steel substrates by cathodic electrophoretic deposition (EPD) with ethanol as suspension medium and poly(acrylic acid) (PAA) as polymeric charging agent. Meanwhile, thesurface morphology was examined using Atomic-force microscopy (AFM). The cross-section AFM showed that the particles sizes for the Al2O3 NPs is around 60-80 nm. The anticorrosion behaviour of coated C.S was investigated in 3.5% NaCl at temperature range 298-328 K by potentiodynamic polarization measurements. Results show that using PAA in suspension coat incr

... Show More
View Publication Preview PDF
Scopus (13)
Scopus
Publication Date
Tue Dec 21 2021
Journal Name
Contemporary Clinical Dentistry
Assessment of maxillary incisors' angulation and position in different types of malocclusions using cone-beam computed tomography
...Show More Authors

Abstract Background: This study is aimed to assess the maxillary incisors’ root position, angulation, and buccal alveolar bone thickness in both genders and different classes of malocclusion using cone‑beam computed tomography (CBCT). Materials and Methods: Two hundred and six CBCT images were gathered and analyzed by three‑dimensional On‑Demand software to measure the variables of 803 maxillary central and lateral incisors. Genders and class difference was determined by unpaired t‑test, one‑way ANOVA, and Chi‑square tests. Results: Buccal root position of the maxillary incisors accounted for in the majority of the cases followed by the middle and palatal positions. The thickness of alveolar bone appears to have nearly the sam

... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Aug 30 2019
Journal Name
Environmental Engineering Research
Numerical modeling of two-dimensional simulation of groundwater protection from lead using different sorbents in permeable barriers
...Show More Authors

This study is to investigate the possibility of using activated carbon prepared from Iraqi date-pits (ADP) which are produced from palm trees (Phoenix dactylifera L.) as low-cost reactive material in the permeable reactive barrier (PRB) for treating lead (Pb<sup>+2</sup>) from the contaminated groundwater, and then compare the results experimentally with other common reactive materials such as commercial activated carbon (CAC), zeolite pellets (ZP). Factors influencing sorption such as contact time, initial pH of the solution, sorbent dosage, agitation speed, and initial lead concentration has been studied. Two isotherm models were used for the description of sorption data (Langmuir and Freundlich). The maximum lead sorp

... Show More
Scopus (25)
Crossref (19)
Scopus Clarivate Crossref