Preferred Language
Articles
/
5hcrWZIBVTCNdQwC96wP
Smart Irrigation Technique in the Fixed Irrigation System Based on Soil Moisture Content
...Show More Authors
Abstract<p>The growing water demand has raised serious concerns about the future of irrigated agriculture in many parts all over the world, changing environmental conditions and shortage of water (especially in Iraq) have led to the need for a new system that efficiently manages the irrigation of crops. With the increasing population growing at a rapid pace, traditional agriculture will have a tough time meeting future food demands. Water availability and conservation are major concerns for farmers. The configuration of the smart irrigation system was designed based on data specific to the parameters concerning the characteristics of the plant and the properties of soil which are measured once in the research (permeability, pH, humidity, porosity, etc.), the soil moisture content sensors are placed in the root zone of plants when the crop needs to be irrigated the sensors send notifications to the user of the system from the application on a smartphone to operate the water pump and on the contrary when the soil saturated the sensors notify the user to turn off the water pump. This paper aims to discuss the aspects related to designing and fabricating an automatic irrigation system using sensors of soil moisture content using this method will save time and money significantly. The study found that the quantity of water consumed to irrigate the yellow corn crop in the portion assigned for smart irrigation technique in an area of 875 m<sup>2</sup> is less than the amount of consumed water utilized in the section allocated for fixed sprinkler irrigation in the same area by 34.444%, furthermore, the yield of the yellow corn crop grown using smart irrigation technique exceeds that of the crop grown by fixed sprinkler irrigation. And also, human intervention will be reduced.</p>
Scopus Crossref
View Publication
Publication Date
Thu Jan 01 2015
Journal Name
اطروحة دكتوراه
The role of Asospirillum brasiliense bacteria isolated from soil of produce some regular growth and hydrolysis enzymes
...Show More Authors

Publication Date
Mon Feb 13 2023
Journal Name
Journal Of Educational And Psychological Researches
Patterns of Feedback Used in the E-Learning System from the Teachers of the First Cycle in the Governorate of Muscat at the Sultanate of Oman
...Show More Authors

 

Abstract

This study aims to identify the degree to which the first cycle teachers use different feedback patterns in the e-learning system in addition to the differences in the degree of use according to specialization, teaching experience, and in-service training in the field of classroom assessment, as well as the interaction between them. The study sample consisted of (350) female teachers of the first cycle in government schools in Muscat Governorate for the academic year 2020/2021. The study used a questionnaire that contained four different patterns of feedback, which are reinforcement, informative, corrective, and interpretive feedback. The psychometric properties of the que

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 06 2022
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Using of costs based on activity that focused on performance in Reduce Costs and their reflection to improve competitive advantage: An applied research in wasitTextile and Knitting factory
...Show More Authors

The research aims mainly to the role of the statement style costs on the basis of activity based on performance (PFABC) to reduce production cost and improve the competitive advantage of economic units and industrial under the modern business environment dominated by a lot of developments and changes rapidly, which necessitates taking them and criticize them to ensure survival and continuity.  The research problem is the inability of traditional cost methods of providing useful information to the departments of units to take many administrative decisions, particularly decisions related to the product and calculating the costs of the quality of the sound and the availability of the need and the ability to replace methods capa

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Iraqi Journal Of Science
Paper based glucose biosensor depending on SPCE modified with hemoglobin and silver nanoparticles
...Show More Authors

The direct electron transfer behavior of hemoglobin that is immobilized onto screen-printed carbon electrode (SPCE) modified with silver nanoparticles (AgNPs) and chitosan (CS) was studied in this work. Cyclic voltametry and spectrophotometry were used to characterize the hemoglobin (Hb) bioconjunction with AgNPs and CS. Results of the modified electrode showed quasi-reversible redox peaks with a formal potential of (-0.245 V) versus Ag/AgCl in 0.1 M phosphate buffer solution (PBS), pH7, at a scan rate of 0.1 Vs-1. The charge transfer coefficient (α) was 0.48 and the apparent electron transfer rate constant (Ks) was 0.47 s-1. The electrode was used as a hydrogen peroxide biosensor with a linear response over 3 to 240 µM and a detection li

... Show More
Scopus
Publication Date
Mon Dec 03 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Condition assessment and rehabilitation for trunk sewer deterioration based on Semi-Markov model
...Show More Authors

An accurate assessment of the pipes’ conditions is required for effective management of the trunk sewers. In this paper the semi-Markov model was developed and tested using the sewer dataset from the Zublin trunk sewer in Baghdad, Iraq, in order to evaluate the future performance of the sewer. For the development of this model the cumulative waiting time distribution of sewers was used in each condition that was derived directly from the sewer condition class and age data. Results showed that the semi-Markov model was inconsistent with the data by adopting ( 2 test) and also, showed that the error in prediction is due to lack of data on the sewer waiting times at each condition state which can be solved by using successive conditi

... Show More
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Modeling and analysis of thermal contrast based on LST algorithm for Baghdad city
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Ingénierie Des Systèmes D Information
Performance Evaluation of Multi-Organization E-Government Based on Hyperledger Fabric Blockchain Platform
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jan 01 2015
Journal Name
International Journal Of Advanced Research
UV Photovoltaic detector based on Bi doped TiO2 Fabricated by Pulse Laser Deposition
...Show More Authors

Pure and doped TiO 2 with Bi films are obtained by pulse laser deposition technique at RT under vacume 10-3 mbar, and the influence of Bi content on the photocvoltaic properties of TiO 2 hetrojunctions is studied. All the films display photovoltaic in the near visible region. A broad double peaks are observed around λ= 300nm for pure TiO 2 at RT in the spectral response of the photocurrent, which corresponds approximately to the absorption edge and this peak shift to higher wavelength (600 nm) when Bi content increase by 7% then decrease by 9%. The result is confirmed with the decreasing of the energy gap in optical properties. Also, the increasing is due to an increase in the amount of Bi content, and shifted to 400nm when annealed at 523

... Show More
Publication Date
Fri Apr 02 2010
Journal Name
Journal Of The University Of Karbala
Spectrophotometric determination of Cisapride Based on ion-pair complex formation with Bromophenol blue
...Show More Authors

A new simple, sensitive and inexpensive method has been developed for the spectrophotometric determination of cisapride in pharmaceutical formulation. The turbidimetric method is based on the formation of the ion-pair complex between the drug and bromophenol blue (BPB) in presence of potassium chloride at pH= 2.6, with a maximum absorbance at 520 nm. The calibration graph is linear in the concentration range 5-50µg.ml-1 , with good correlation coefficient (r = 0.9989).The limit of detection was found to be 1.14 µg.ml-1 and no interference was observed from common excipients in the pharmaceutical preparation that contain cisapride with good accuracy and precision.

Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Low-Rate High-Quality Parametric Audio Coder based on Sinusoidal plus Noise Representations
...Show More Authors

This paper presents a parametric audio compression scheme intended for scalable audio coding applications, and is particularly well suited for operation at low rates, in the vicinity of 5 to 32 Kbps. The model consists of two complementary components: Sines plus Noise (SN). The principal component of the system is an. overlap-add analysis-by-synthesis sinusoidal model based on conjugate matching pursuits. Perceptual information about human hearing is explicitly included into the model by psychoacoustically weighting the pursuit metric. Once analyzed, SN parameters are efficiently quantized and coded. Our informal listening tests demonstrated that our coder gave competitive performance to the-state-of-the- art HelixTM Producer Plus 9 from

... Show More
View Publication Preview PDF