Preferred Language
Articles
/
5hcrWZIBVTCNdQwC96wP
Smart Irrigation Technique in the Fixed Irrigation System Based on Soil Moisture Content
...Show More Authors
Abstract<p>The growing water demand has raised serious concerns about the future of irrigated agriculture in many parts all over the world, changing environmental conditions and shortage of water (especially in Iraq) have led to the need for a new system that efficiently manages the irrigation of crops. With the increasing population growing at a rapid pace, traditional agriculture will have a tough time meeting future food demands. Water availability and conservation are major concerns for farmers. The configuration of the smart irrigation system was designed based on data specific to the parameters concerning the characteristics of the plant and the properties of soil which are measured once in the research (permeability, pH, humidity, porosity, etc.), the soil moisture content sensors are placed in the root zone of plants when the crop needs to be irrigated the sensors send notifications to the user of the system from the application on a smartphone to operate the water pump and on the contrary when the soil saturated the sensors notify the user to turn off the water pump. This paper aims to discuss the aspects related to designing and fabricating an automatic irrigation system using sensors of soil moisture content using this method will save time and money significantly. The study found that the quantity of water consumed to irrigate the yellow corn crop in the portion assigned for smart irrigation technique in an area of 875 m<sup>2</sup> is less than the amount of consumed water utilized in the section allocated for fixed sprinkler irrigation in the same area by 34.444%, furthermore, the yield of the yellow corn crop grown using smart irrigation technique exceeds that of the crop grown by fixed sprinkler irrigation. And also, human intervention will be reduced.</p>
Scopus Crossref
View Publication
Publication Date
Tue Jan 01 2013
Journal Name
Iraqi Journal Of Science
Using of Remote Sensing Technique to Monitor The Status of The Plant and Change Detection for Three Different Periods in Western Region in Baghdad/ Iraq
...Show More Authors

Data of multispectral satellite image (Landsat- 5 and Landsat-7) was used to monitoring the case of study area in the agricultural (extension and plant density), using ArcGIS program by the method of analysis (Soil adjusted vegetative Index). The data covers the selected area at west of Baghdad Government with a part of the Anbar and Karbala Government. Satellite image taken during the years 1990, 2001 and 2007. The scene of Satellite Image is consists of seven of spectral band for each satellite, Landsat-5(TM) thematic mapper for the year 1990, as well as satellite Landsat-7 (ETM+) Enhancement thematic mapper for the year 2001 and 2007. The results showed that in the period from 1990 to 2001 decreased land area exposed (bare) and increased

... Show More
View Publication
Publication Date
Tue Feb 19 2019
Journal Name
Heat And Mass Transfer
Mass transfer characteristics of a flow-by fixed bed electrochemical reactor composed of vertical stack stainless steel screens cathode
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
2015 7th Computer Science And Electronic Engineering Conference (ceec)
An experimental investigation on PCA based on cosine similarity and correlation for text feature dimensionality reduction
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Optimum conditions for ascorbic acid determination in three Iraqi citrus using HPLC technique
...Show More Authors

A high-performance liquid chromatography method was employed for the quantitative determination of ascorbic acid (AA) which called vitamin C in three types of Iraqi citrus (orange mandarin and aurantium ) and to establish this goal , evaluation of ascorbic acid degradation is so important due to its significant criticality when exposure to ordinary atmospheric conditions. The chromatographic analysis of AA was carried out after their sequential elution with KH2PO4 ( as mobile phase) by reverse-phase HPLC technique with C8 column and UV detection at 214 nm. .Bad resolutions was appeared clearly for C8 column , so another alternative condition were carried out to improve the resolution by replacement of C8 by C18 column .Statistical treat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 04 2025
Journal Name
Engineering, Technology &amp; Applied Science Research
Damage Assessment for Refinement Towers in Oil Installations using 3D Laser Scanning Technique
...Show More Authors

Terrestrial Laser Scanning (TLS) can be used to detect damage and analyze volumetric changes in large structural test specimens. Compared to traditional imaging and surface analysis methods, the primary reason for using 3D scanning is the difficulty of attaching targets to towers of varying heights, as well as the fact that some towers are covered with insulating materials that obscure key landmarks. In addition, the large number of incoming and outgoing pipes and stairs attached to the towers further complicates traditional assessment methods. This research focuses on assessing the damage to the three refining towers at the Baiji Refinery facility. Scanning was performed using a 3D laser scanner with HDR color imaging, capturing da

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Mar 01 2014
Journal Name
Glob. J. Mol. Evol. Genom
Genetic diversity and relationships among Verbascum species in Iraq by RAPD-PCR technique
...Show More Authors

Publication Date
Sun Mar 29 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Photocatalytic Degradation of Reactive Yellow Dye in Wastewater using H2O2/TiO2/UV Technique
...Show More Authors

In the present study, advanced oxidation treatment, the TiO2 /UV/H2O2  process was applied to decolorisation of the reactive yellow dyes in aqueous solution. The UV radiation was carried out with a 6 W low-pressure mercury lamp. The rate of color removal was studied by measuring the absorbency at a characteristic wavelength. The effects of H2O2 dosage, dye initial concentration and pH on decolorisation kinetics in the batch photoreactor were investigated. The highest decolorisation rates were observed (98.8) at pH range between 3 and 7. The optimal levels of H2O2 needed for the process were examined. It appears that high levels of H2O2 could reduce decolori

... Show More
View Publication Preview PDF
Crossref (24)
Crossref
Publication Date
Sun Jun 01 2008
Journal Name
Baghdad Science Journal
Ligand reduction in variously substituted cerium (IV) tetrakis acetylacetone complexes by electrochemistry technique
...Show More Authors

In this work, substantial evidence was obtained for ligand reduction in cerium tetrakis acac complexes. Also, this ligand reduction of a negatively charged ligand proved to depend far less on the nature central metal than neutral ligands does. It is supposed that in Mz(acac)z complexes the charge is distributed evenly over the whole molecule. In this work these complexes were prepared and characterized by IR and CHN analysis to indicate the purities of these complexes. The electrochemistry techniques were shown as obtained for ligand reduction. This research was carried out at School of Chemistry and Molecular Science, Sussex University, U.K.

View Publication Preview PDF
Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Acta Chromatographica
A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form
...Show More Authors

A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi

... Show More
View Publication
Scopus (31)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Sat Jul 08 2017
Journal Name
Neural Computing And Applications
A new algorithm of modified binary particle swarm optimization based on the Gustafson-Kessel for credit risk assessment
...Show More Authors

View Publication
Scopus (35)
Crossref (34)
Scopus Clarivate Crossref