Background: A noninvasive method of determining the severity of coronary artery disease (CAD) is the use of cardiac biomarkers. This study aimed to investigate the use of serum levels of high-sensitivity cardiac troponin I (hs-cTnI) and N-terminal pro–B-type natriuretic peptide (NT-proBNP) in determining CAD severity.Methods: This cross-sectional study included 125 participants categorized by coronary angiographic results into 3 groups: group I (no or < 50% stenosis), group II (1 or 2 vessels with ≥ 50% stenosis), and group III (left main stem or ≥ 3 vessels with ≥ 50% obstruction). Serum hs-cTnI and NT-proBNP levels were measured by enzyme-linked immunosorbent assay. Data were analyzed using SPSS version 25.0 and described as percentages, means, medians, and interquartile ranges (Q1–Q3). Receiver operating characteristic curves and relative quality were applied for both biomarkers.Results: Median hs-cTnI and NT-proBNP levels were higher in group III than in groups I and II (P = .001). Both were higher in group II than in group I (P = .001). Receiver operating characteristic analysis showed that hs-cTnI and NT-proBNP effectively discriminated vascular obstruction severity with high sensitivity and specificity. Relative quality testing results showed a slight increase in predictive ability when the 2 biomarkers were combined.Conclusions: Serum hs-cTnI and NT-proBNP levels, combined or separately, can be used to assess CAD severity concerning the number of diseased vessels, which may help improve risk stratification and management strategy selection. (Iranian Heart Journal 2026; 27(3): 20-26)
Heart failure (HF) is characterized by family history and clinical examination combined with diagnostic tools such as electrocardiogram, chest x-ray and an assessment of left ventricular function by echocardiography. An early diagnosis of heart failure is still based on symptoms of dyspnea, fatigue and signs of fluid overload. Serum N-terminal pro-B-type natriuretic peptide (NT-pro BNP) is cardiac biomarker has emerged as potential predictor of heart failure. It is used as a sensitive biomarker in diagnosis and assessment severity of heart failure. This study assed the diagnostic value of (NT-pro BNP), in Iraqi children patients with heart failure and its correlation with LVEF% especially in emergency rooms of hospitals.Ninety (90) consecut
... Show MoreObjective: This study aims to assess the awareness of patients suffering from cardiovascular
diseases.
Methodology: A descriptive design was applied in this study. A purposive sample consisted of
(100) patients with cardiovascular disease in the Mosul's hospitals were interviewed to achieve study
objectives. A questionnaire was used for data collection after tested for validity and reliability by pilot
study.
Results: The study results showed the mean of patients awareness are (1.78) cut point of (3) and
the majority of patients84% were aged more than 50 years or above. Slightly increase proportion of
male more than females. Most of them are married81%, retired, smokers, and a period of developing
the disease a
Objective: to assess the risk factors of coronary artery disease patients.
Methodology: A non-probability (purposive) sample of (100) patients. The study population consisted of
a sample of adults from both genders whose ages were 30 years and more, and was newly diagnosed as
having CAD by coronary angiography in the cardiac catheterization unit of An Nasiriyah heart center.
Results: The result of the study showed that the most common modifiable risk factors were low HDL-C
levels (58%), smoking (53%), hypertension (46%), diabetes mellitus (34%), obesity (30%), high
triglycerides (19%), hypercholesterolemia (17%), and high LDLC (14%). All these factors were positively
and significantly associated with the development
Objectives of the study: The study aims to assess satisfy of the coronary artery patients for the care product from
the nurse and physician and to find out the relationship between patient satisfaction with the social and the
clinical characteristics of the patients.
Methodology: A descriptive design study conducted using the evaluation approach for the duration of June 3
rd
2012 to January 31, 2013. Non-probability sample of (60) patients who were visiting or admitted (inpatient or
outpatient) to the teaching hospital in Baquba with the diagnosis of coronary artery disease. A questionnaire have
been built and develop by the researcher based on review of literature and previous research, the form included of
(3) p
Objectives This study aimed to compare the clinical effectiveness of four aligning archwires: Superelastic Nickel-Titanium (Superelastic-NiTi), SmartArch, Copper-Nickel-Titanium (Cu-NiTi), and Speed Tubular coaxial-Nickel-Titanium (Tubular coaxial-NiTi), regarding the alignment efficiency, associated perception of pain, and possibility of inducing root resorption.
Materials and Methods This study includes two randomized clinical trials run in parallel. Patients with 5 to 9 mm of mandibular anterior teeth crowding according to Little's irregularity index (LII) who needed fixed orthodontic appliances without extraction were randomly assigned to four groups of
Praise be to God alone, and prayers and peace be upon the one after whom there is no prophet, and after:
This is a regular judicial search for the issuance, validity, and cancellation of regulations in the Saudi system. It came in an introduction and four demands and a conclusion of the most important results, then a list of the most important sources and references, in which I presented: A brief study on the issuance of regulations in the Kingdom of Saudi Arabia and the stages that they pass through, their validity and application, and the rules that govern this system in terms of people, places and times, then canceling and amending regulations And its rulings, I referred to it to the original sources approved in this section,
... Show MoreTo detect the amount of rifampicin in bulk and medicinal dosage formulations, an accurate and costeffective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of rifampicin. This range of wavelengths (300–356 nm) was chosen. The method showed linearity in the 2–22 μg/mL range, with R2 being2 0.9996. The developed method’s linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the str
... Show MoreTo detect the amount of Rifampicin in bulk and medicinal dosage formulations, an accurate, and cost-effective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of Rifampicin. This range of wavelengths (300–356) nm was chosen. The method showed linearity in the 2-22 μg/mL range, with R2 being 0.9996. The developed method' linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of Rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the struct
... Show MoreBackground: Acute coronary syndrome (ACS) is a common disease, and a major determinant of morbidity and mortality in all races. The pleiotropic effects of the receptor activator of nuclear factor-kappa B ligand (RANKL) such as modulation of cell survival, mineralization and inflammation, make it an interesting candidate mediator in the progression and destabilization of atherosclerotic lesions.Objectives: This study was performed to investigate the role of RANKL in the pathogenesis of ACS.Methods: The levels of RANKL were measured by ELISA method in sera of 60 ACS patients, 31 patients with unstable angina (UA) and 29 patients with myocardial infarction (MI) in comparison with 20 apparently healthy controls.Results: Current data indicate
... Show More