Background: A noninvasive method of determining the severity of coronary artery disease (CAD) is the use of cardiac biomarkers. This study aimed to investigate the use of serum levels of high-sensitivity cardiac troponin I (hs-cTnI) and N-terminal pro–B-type natriuretic peptide (NT-proBNP) in determining CAD severity.Methods: This cross-sectional study included 125 participants categorized by coronary angiographic results into 3 groups: group I (no or < 50% stenosis), group II (1 or 2 vessels with ≥ 50% stenosis), and group III (left main stem or ≥ 3 vessels with ≥ 50% obstruction). Serum hs-cTnI and NT-proBNP levels were measured by enzyme-linked immunosorbent assay. Data were analyzed using SPSS version 25.0 and described as percentages, means, medians, and interquartile ranges (Q1–Q3). Receiver operating characteristic curves and relative quality were applied for both biomarkers.Results: Median hs-cTnI and NT-proBNP levels were higher in group III than in groups I and II (P = .001). Both were higher in group II than in group I (P = .001). Receiver operating characteristic analysis showed that hs-cTnI and NT-proBNP effectively discriminated vascular obstruction severity with high sensitivity and specificity. Relative quality testing results showed a slight increase in predictive ability when the 2 biomarkers were combined.Conclusions: Serum hs-cTnI and NT-proBNP levels, combined or separately, can be used to assess CAD severity concerning the number of diseased vessels, which may help improve risk stratification and management strategy selection. (Iranian Heart Journal 2026; 27(3): 20-26)
A new Ni(II) nanostructured chelating system (DHN) was introduced for selective optical heavy-metal ion sensing in an aqueous medium. The cooperative chelating system comprising 8-hydroxyquinoline (8-HQ) and dimethylglyoxime (DMG) has been developed for the first time in association with fibre optic sensing for selective optical heavy-metal ion sensing in an aqueous medium. The Ni(II) nanocompound fluoresces upon 578 nm excitation, showing a highly sensitive optical response with a linear calibration curve in the range 0–100 ng/mL. The regression equation of the calibration curve is y = 0.0035x + 0.9990, which indicates very good linearity, implying R2 = 0.999 with high sensitivity (calibration slope of 0.0035) and low baseline noise (bla
... Show MoreThe aim of this work is to detect the best operating conditions that effect on the removal of Cu2+, Zn2+, and Ni2+ ions from aqueous solution using date pits in the batch adsorption experiments. The results have shown that the Al-zahdi Iraqi date pits demonstrated more efficient at certain values of operating conditions of adsorbent doses of 0.12 g/ml of aqueous solution, adsorption time 72 h, pH solution 5.5 ±0.2, shaking speed 300 rpm, and smallest adsorbent particle size needed for removal of metals. At the same time the particle size of date pits has a little effect on the adsorption at low initial concentration of heavy metals. The adsorption of metals increases with increas
... Show MoreIn this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these
... Show MoreThe simulation of passively Q-switching is four non – linear first order differential equations. The optimization of passively Q-switching simulation was carried out using the constrained Rosenbrock technique. The maximization option in this technique was utilized to the fourth equation as an objective function; the parameters, γa, γc and β as were dealt with as decision variables. A FORTRAN program was written to determine the optimum values of the decision variables through the simulation of the four coupled equations, for ruby laser Q–switched by Dy +2: CaF2.For different Dy +2:CaF2 molecules number, the values of decision variables was predicted using our written program. The relaxation time of Dy +2: CaF2, used with ruby was
... Show MoreThis article introduces a novel procedure to detect an approximate solution to Fredholm fractional integro-differential equations with linear type (LFFIDE) defined using Caputo fractional derivative. The new procedure approximates the solution using three types of polynomials: Laguerre polynomials, Hermite polynomials, and Legendre polynomials, thereafter transforming the problem into a linear programming problem. The approximate solutions are compared using testing examples to examine the efficiency of the suggested approach. Also, a comparison with the other methods using the same polynomials illustrates The effectiveness and consistency of the proposed technique. Finally, the error analysis of the proposed technique and convergent are di
... Show More