Abstract To estimate the seroprevalence of HCV infection among HIV-infected haemophiliacs and to demonstrate the most prevalent HCV genotype, 47 HIV-infected haemophilia patients were screened for anti-HCV antibodies. By performing polymerase chain reaction and DNA enzyme immunoassay, HCV-RNA was detected with subsequent genotyping. Seroprevalence of anti-HCV antibodies was 66.0%. Of 31 HCV/HIV co-infected patients, 21 (67.7%) had no history of blood transfusion. We detected 4 HCV genotypes: 1a, 1b, 4 and 4 mixed with 3a, HCV-1b being the most frequent. Contaminated factor VIII (clotting factor) could be responsible for disease acquisition.
SJ Mohammed, AA Noaimi, KE Sharquie, JM Karhoot, MS Jebur, JR Abood, A Al-Hamadani, Al-Qadisiyah Medical Journal, 2015 - Cited by 20
Power systems are generally required to operate near their maximum capacity. Thus, there is an increased focus on improving real power system capacities through the installation of novel devices, including the Flexible AC Transmission Systems (FACTs). This paper discusses the optimal incorporation of thyristor-controlled series capacitor (TCSC) in the 400 kV Baghdad grid of the Iraqi network as a suggested method to control the power transfer of a transmission line (TL) and suppress Sub-Synchronous Resonance (SSR). The MATLAB 2019 simulation is executed utilizing the phase angle as an index to select an appropriate TCSC location. Nine places were chosen based on eigenvalues, and three suitable places were determined, where 0.5< X
... Show MoreWater drainage pattern in the rivers and changed the nature of the renewed feeding areas
in the basin in terms of topographic and geological conditions and climate in addition to the
human role in organizing the process flow within these basins. This study addressed the
development of the Tigris River Hydrological in the city of Baghdad and found that the
annual rate of water drainage in the Tigris River was driven down very significantly,
especially in the past twenty years, and since 1996 up to 2014 record flow rates of less than
the overall rate of discharge of water, a (950 m3 / s ), in addition to the quarterly decrease the
discharge rates, especially since the beginning of the year 2000 and took converge all fo
Firstly, in this study, a brief updated description and applications of different solar collectors used in renewable energy systems for supplying electric and thermal energy was presented. Secondly, an attempt was made to utilize tilting orientation of solar collector for maximizing collector energy with time in respect to horizontal orientation. For energy calculation, global solar radiation was used since they are directly related. For that purpose, field measurements of half-hourly radiation on two flat panels of tilting and horizontal orientations were carried out throughout 8-month period under local climate of Baghdad. Then, energy gain and radiation level averages were calculated based on the field radiation
... Show More
