Abstractin adult typical atrioventricular nodal reentrant tachycardia (AVNRT) consider most common paroxysmalsupraventricular tachycardia. Dual pathway idea still accepted and used widely and commonly. According tothe guide line, ablations of slow pathway still the first treatment with good success rate.Identify the electrophysiological difference of atrioventricular nodal pathways pre and post ablation.Electrophysiological study was done to 54 patients with only typical type AVNRTs; they were 40 (74%)females and 14 (26%) males. Divided into two groups G1 with 38 patients (70.4%) having one pathway andG2 with 16 patients (29.6%) with multiple pathway. After induction we study the clinical andelectrophysiological feature of tachycardia and showed faster tachycardia in G1 than G2 (330 ±56 versus 430±67). And the time per minute to achieve ablation or end point more in G2 than G1 (82±12.4 G2 versus71±11.6 G1) with more energy applied in G2 versus G1 (12.4± 4.8 versus 6.3± 3.2). Complete ablation of theslow pathway was achieve in 37(69%) of total patients and only modulation occur in 17 (31%) with variationbetween two groups. And block not recorded in this study.In patient with typical AVNRTs there is percentage of multiple AV pathways 29.6%, and during EPprocedure those need good interpretation, analysis of tachycardia after induction, pre and post ablation, andalso they need more time and energy for elimination of slow pathway as well as the used of mapping system tolocalized the His area before ablation is of value to prevent AV nodal injury (PDF) Dual and Multiple AV Nodal Pathways, What is The Deference in Typical Atrioventricular Nodal Reentrant Tachycardia. Available from: https://www.researchgate.net/publication/361710553_Dual_and_Multiple_AV_Nodal_Pathways_What_is_The_Deference_in_Typical_Atrioventricular_Nodal_Reentrant_Tachycardia [accessed Sep 01 2022].
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreThis study uses an environmentally friendly and low-cost synthesis method to manufacture zinc oxide nanoparticles (ZnO NPs) by using zinc sulfate. Eucalyptus leaf extract is an effective chelating and capping agent for synthesizing ZnO NPs. The structure, morphology, thermal behavior, chemical composition, and optical properties of ZnO nanoparticles were studied utilizing FT-IR, FE-SEM, EDAX, AFM, and Zeta potential analysis. The FE-SEM pictures confirmed that the ZnO NPs with a size range of (22-37) nm were crystalline and spherical. Two methods were used to prepare ZnO NPs. The first method involved calcining the resulting ZnO NPs, while the second method did not. The prepared ZnO NPs were used as adsorbents for removing acid black 210
... Show MoreA set newly complexes with the general formula [M(L)Cl2] are resulting from the reaction of a new schiff base ligand [Ethyl (6R,7R)-7-((E)-2-((2-ethoxy-2- oxoethoxy)imino)-2-(2-(((E)-4-nitrobenzylidene) amino) thiazol -4- yl) acetamido) -8- oxo -3- vinyl -5- thia -1-aza bicyclo [4. 2.0] oct -2- ene -2- carboxylate] (L). This ligand was derived from the reaction of the two substances 4-nitrobenzaldehyde and precursor (P). Reaction the ligand with metal ions M= Mn(II), Co(II), Ni(II), Cu(II) and Cd(II) afforded new complexes which are characterized by FT-IR and Electronic Spectra. These measurements indicate that the complexes have a tetrahedral geometry. The Penicillin-Binding Protein 3 (PBP3) of Staphylococcus aureus and the target protein
... Show MoreSome new norms need to be adapted due to COVID-19 pandemic period where people need to wear masks, wash their hands frequently, maintain social distancing, and avoid going out unless necessary. Therefore, educational institutions were closed to minimize the spread of COVID-19. As a result of this, online education was adapted to substitute face-to-face learning. Therefore, this study aimed to assess the Malaysian university students’ adaptation to the new norms, knowledge and practices toward COVID-19, besides, their attitudes toward online learning. A convenient sampling technique was used to recruit 500 Malaysian university students from January to February 2021 through social media. For data collection, all students
... Show MoreA specific, sensitive and new simple method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation of ion pair compound between methyldopa and potassium hexacyanoferrate in acidic medium to obtain a yellow precipitate complex using long distance chasing photometer (NAG-ADF-300-2). The linear range for calibration graph was 0.05-35 mmol/L for cell A and 0.05-25 mmol/L for cell B, and LOD 1.4292 µg /200 µL for both cells with correlation coefficient (r) 0.9981 for cell A and 0.9994 for cell B, RSD% was lower than 0.5 % for n=8 for. The results were compared with classical method UV-Spectrophotometric at λ max=280 nm and turbi
... Show MoreThis study expands the state of the art in studies that assess torsional retrofit of reinforced concrete (RC) multi-cell box girders with carbon fiber reinforced polymer (CFRP) strips. The torsional behavior of non-damaged and pre-damaged RC multi-cell box girder specimens externally retrofitted by CFRP strips was investigated through a series of laboratory experiments. It was found that retrofitting the pre-damaged specimens with CFRP strips increased the ultimate torsional capacity by more than 50% as compared to the un-damaged specimens subjected to equivalent retrofitting. This indicated that the retrofit has been less effective for the girder specimen that did not develop distortion beforehand as a result of pre-loading. From
... Show More