A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 µg∙mL-1 for Ciprofloxacin and 2 to 22 µg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) were measured with first derivative method. The LOD and LOQ were found as 0.45 µg∙mL-1 and 1.50 µg∙mL-1 for Ciprofloxacin and 0.68 µg∙mL-1 and 2.28 µg∙mL-1 for Isoniazid, respectively. Accuracy and precision were determined by measuring the relative standard deviation and recoveries. The results also showed that the proposed method was successfully applied for direct analysis of ciprofloxacin and isoniazid in the tablet samples
This study is concentrated to investigate the effects of aeration and stirring speed on the volumetric mass transfer coefficient (KLa). A dynamic technique was used in estimating KLa values in order to achieve the aim of this study.
This study was done in 10L bioreactor by using two medias:-
- Dionized water
- Xanthan solution (1 g /L)
Moreover, the research covered a comparison between the obtained values of KLa.
The Xanthan solution was used because of its higher viscosity in comparison with water. It behaves similarly to the cultivation medium when organisms are cultivated in a bioreactor. Growth of organisms in the reactor l
... Show MoreResveratrol is polyphenolic compound has many biochemical and biological effects on several organs. Therefore, resveratrol can be used to treat many diseases. The aim was to evaluate resveratrol safety when used in a parenteral single bolus dose. This study was conducted on 60 mice (30 males and 30 females). Each male and female mice divided into 6 groups (five mice per group). All mice groups given 1% DMSO and five different doses of resveratrol (5, 2.5, 1.25, 0.625, 0.312) gm/kg intraperitonially given to five groups respectively. The mice were continuously monitored during 14 days. The number of deaths, changes in general behavior, changes in physiological activity, and signs of toxicity were reported. On day 15 blood was
... Show MoreAzithromycin is the drug of choice in the treatment of several bacterial infections, most often those causing middle ear infection, bronchitis, pneumonia, typhoid and sinusitis. It’s also effective against certain urinary tract infections and venereal diseases. This study was carried out to prepare an acceptable suspension either as dry physical mixture powder or granules to be reconstituted, through studying the effect of various type and concentration of suspending agent (xanthan gum, hydroxypropyl methylcellulose (HPMC), either alone or in combination) on the release profile of the drug. The best prepared suspension formulas (H& III) were selected depending on the dissolution profile of each formulas and then compared with
... Show MoreCarbamazepine is an anticonvulsant agent which acts on the central nervous system and used for the treatment of epilepsy. Carbamazepine was formulated as an oral extended release tablets using ethyl cellulose as retardant substance. Different types of tablets additives such as cellulose materials (sodium carboxymethyl cellulose and microcrystalline cellulose ), lactose, calcium phosphate and solubilizing agents ( sodium lauryl sulphate and polyethylene glycol 6000) were utilized to study their effect on the release profile of drug from ethyl cellulose matrices. It was found that sodium carboxymethyl cellulose increased the carbamazepine release and the same effect was obtained when the same amount of microcrystalline cellulose used
... Show MoreLoratadine is a long acting non-sedating anti-histaminic agent that was developed for the treatment of seasonal allergic rhinitis, whose anti-histaminic action is more effective than the other anti-histaminic drugs available commercially. This project was carried out to prepare an acceptable suspension through studying the release of drug in presence of different types and concentrations of suspending agents such as polysorbate 40, xanthan gum, sodium carboxymethylcellulose (NaCMC), aluminum magnesium silicate (veegum) and sodium alginate. The effects of these suspending agents were studied at pH 1.2 (0.1N HCl) and 37 Ù’C. The results showed that the release rate of loratadine in the presence of these suspending agents was dependent o
... Show MoreThe aim of this work is the synthesis of new Schiff base derived from PVA and Erythro-ascorbic acid derivative (pentulosono-ɣ-lactone-2,3-enedianisoate) and its metal complexes of biological significance. All synthesized compounds were characterized by Thin layer chromatography (TLC) and FTIR spectra and aldehyde was also characterized by (U.V-Vis), 1HNMR, 13CNMR and mass spectra. The synthesized Schiff base & its metal complexes were screened for their in vitro antimicrobial activity against five pathogenic bacteria (Escherichia coli, Shigella dysentery,Klebsiellapneumonae,Staphylococcusaureus, Staphylococcus Albus) and two fungal (Aspergillus Niger,Yeast).The biological activity ofall complexes is higher than free Schiff base ligand andf
... Show MoreHigh-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreA new, simple, rapid and sensitive spectrophotometric method for the determination of sulfamethoxazole in both pure form and pharmaceutical preparations has been reported.The adapted technique based on utilization 4-aminobenzene sulfonic acid as a new modern chromogenic through an oxidative coupling reaction with sulfamethoxazole and potassium iodate in basic media to form orange soluble dye product with absorption maxima at 490 nm. Subject to Beer's law in the range 2–32μg mL-1. The values of molarabsorption coefficient (ε) and correlation coefficient were found to be 9.118 × 103 and0.9999 respectively whereas the Sandels index was
... Show MoreIn this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m
... Show MoreA novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%
... Show More