Preferred Language
Articles
/
5HhzQqABuRolNscLdO1m
Thermo-hydraulic performance improvement of a triangular solar air collector using homogeneous and paired-graded metal foam configurations
...Show More Authors

A numerical investigation was performed on triangular solar air collectors by integrating unique layouts of triangular and alternating triangular copper metal foams with graded and non-graded pore densities. A three-dimensional CFD model was established to solve the governing equations of coupled systems for porous and non-porous domains. The two-energy-equations model was implemented to simulate heat transfer in porous media. The mathematical model was validated with numerical and experimental tests, with maximum mean absolute percentage error of 5% and 7%, respectively. To compromise heat transfer improvement with pressure losses, a partial metal foam insertion was adopted, covering 10% to 25% of the air duct volume. The findings indicate a significant enhancement compared to conventional design, particularly for the third triangular metal foam sample characterized by high pore density and elevated permeability. Improved mixing, augmented heat exchange surface area, and localized turbulence intensification contributed to the noted gains in performance. The findings confirm that the spatial distribution and graded pore densities of metal foams are a promising approach for improving performance. Furthermore, the alternating configuration facilitated flow redistribution while mitigating excessive pressure penalties. Thermal and thermo-hydraulic efficiencies, as well as the performance evaluation criterion, rose from 63.22% to 85.39%, 53.69% to 71.91%, and 2.70 to 5.02, respectively, when the metal foam volume fraction was increased from 10% to 25%. Such systems can be integrated into building as part of energy transition scenario to decrease carbon dioxide emissions and improve overall energy efficiency.

Crossref
View Publication
Publication Date
Tue Nov 01 2022
Journal Name
Energy Reports
Thermal effectiveness of solar collector using Graphene nanostructures suspended in ethylene glycol–water mixtures
...Show More Authors

View Publication
Scopus (21)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Thu Oct 03 2024
Journal Name
Heat Transfer
Field study of a cubical integrated solar collector storage tank under Baghdad province
...Show More Authors
Abstract<p>A new, easy‐to‐manufacture, and low‐cost integrated cubical solar collector tank for domestic usage is concerned in this work. Three models are prepared, side by side, and tested to point out their seasonal performance. Tank Model I has three vertical sides, black painted and glazed to act as an absorber; the other sides are insulated. Tank Model II has two black painted and glazed sides, with four insulated surfaces. The models are south‐oriented at different positions and tested versus the conventional tank (Model III) to validate and assess their performance in summer and winter. In summer, the temperatures in Models I and II are lower than those for Model III since they have insulated sid</p> ... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Tue Feb 13 2018
Journal Name
Journal Of Optics
Solar selective performance of metal nitride/oxynitride based magnetron sputtered thin film coatings: a comprehensive review
...Show More Authors

View Publication
Scopus (35)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
The Effect of Hydraulic Accumulator on the Performance of Hydraulic System
...Show More Authors

The purpose of this paper is to depict the effect of adding a hydraulic accumulator to a hydraulic system. The experimental work includes using measuring devices with interface to measure the pressure and the vibration of the system directly by computer so as to show the effect of accumulator graphically for real conditions, also the effects of hydraulic accumulator for different applications
have been tested. A simulation analysis of the hydraulic control system using MATLAB.R2010b to study was made to study the stability of the system depending on the transfer function, to estimate the effect of adding the accumulator on stability of the system. A physical simulation test was made for the hydraulic system using MATLAB to show the ef

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
Energy Analysis of Solar Collector With perforated Absorber Plate
...Show More Authors

The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases  the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decr

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Feasibility Study of a Solar Flat Plate Collector for Domestic and Commercial Applications under Iraq Climate
...Show More Authors

View Publication
Scopus (10)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Apr 27 2022
Journal Name
Arabian Journal For Science And Engineering
Optical and Thermal Performance of a Parabolic Trough Collector for Different Receiver Geometries
...Show More Authors

This paper numerically and theoretically investigates the optical and thermal performance of a parabolic trough collector PTC system. Many numerical simulations and theoretical analyses are conducted to demonstrate the influence of the receiver geometry and shifting from the focal position on the optical performance. The examined receiver geometries are circular, square, triangular, elliptical, and the new circular–square combined geometry is named as channel receiver. The thermal performance of PTC is examined for different volume flow rates theoretically in the range of (0.36 to 2.4 lpm). The results show that the best optical design is the channel receiver with an intercept factor of 84%, while the worst is the elliptical receiver with

... Show More
View Publication
Scopus (21)
Crossref (12)
Scopus Crossref
Publication Date
Fri May 31 2019
Journal Name
Journal Of Engineering
Numerical Investigation of Heat Transfer Enhancement of Double Pipe Heat Exchanger Using Metal Foam Fins
...Show More Authors

The influence of adding metal foam fins on the heat transfer characteristics of an air to water double pipe heat exchanger is numerically investigated. The hot fluid is water which flows in the inner cylinder whereas the cold fluid is air which circulates in the annular gap in parallel flow with water. Ten fins of metal foam (Porosity = 0.93), are added in the gap between the two cylinder, and distributed periodically with the axial distance. Finite volume method is used to solve the governing equations in porous and non-porous regions. The numerical investigations cover three values for Reynolds number (1000 ,1500, 2000), and Darcy number (1 x10-1, 1 x10-2, 1x10-3). The comparison betwee

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Fri Nov 11 2011
Journal Name
Thesis
Performance Analysis of a New Compact Magneto-Rheological Proportional Control Valve for Hydraulic Actuation Using FEM and Experimental Approach
...Show More Authors

One of the main parts in hydraulic system is directional control valve, which is needed in order to operate hydraulic actuator. Practically, a conventional directional control valve has complex construction and moving parts, such as spool. Alternatively, a proposed Magneto-rheological (MR) directional control valve can offer a better solution without any moving parts by means of MR fluid. MR fluid consists of stable suspension of micro-sized magnetic particles dispersed in carrier medium like hydrocarbon oil. The main objectives of this present research are to design a MR directional control valve using MR fluid, to analyse its magnetic circuit using FEMM software, and to study and simulate the performance of this valve. In this research, a

... Show More
Publication Date
Sat Nov 01 2025
Journal Name
Iop Conference Series: Earth And Environmental Science
Improving the Hydraulic Performance of Bani-Hassan Canal by Using Submerged Weir
...Show More Authors
Abstract<p> A submerged weir is a hydraulic structure utilized to control flow in canals and rivers. Water scarcity is a persistent issue in Iraq, especially during the dry season when irrigation withdrawals reduce downstream water levels in canals (Water is lost from irrigation canals due to seepage, evaporation, and vegetation growth). The final section of the Bani Hassan Canal experiences significant drops in water surface (WS) levels, negatively impacting irrigation efficiency. This study addresses that gap by investigating the use of submerged weirs to enhance water distribution and raise WS in the final 6 km segment of the canal. A one-dimensional (1D) hydraulic mode</p> ... Show More
View Publication
Scopus Crossref