Salivary peroxidases have biological functions of particular importance to oral health. The aim of this paper is to shed the light on saliva and serum total peroxidases activity as well as the activity of each of salivary peroxidase (SPO) and myeloperoxidase (MPO) in patients with oral tumors. The studied participants were divided into two groups: the first group included 18 oral squamous cell carcinoma patients and 20 age and gender-matched healthy controls while the second group consisted of 20 oral ossifying fibroma patients and 23 age and gender-matched healthy controls. Total peroxidases activity was determined, and its specific activity was calculated in serum and whole mixed saliva as well as in the supernatant and pellet fractions of saliva. Furthermore, the activities of SPO and MPO were determined in each of saliva’s supernatants and saliva’s pellet fractions, and the thiocyanate (SCN-) concentration was measured in the supernatants fraction only. The results indicated the presence of a significant increase in the activity of both total peroxidase and MPO (p = 0.0001) in the salivary supernatants of oral squamous cell carcinoma patients relative to the control group. A significant increase (p = 0.0001) in total peroxidase activity in patients with oral ossifying fibroma was also found in serum compared with healthy individuals. In this study, we have shown that the measurement of total peroxidase and MPO activities in saliva may be used as an adjuvant tool for monitoring patients with oral malignancies
In the presence of deep submicron noise, providing reliable and energy‐efficient network on‐chip operation is becoming a challenging objective. In this study, the authors propose a hybrid automatic repeat request (HARQ)‐based coding scheme that simultaneously reduces the crosstalk induced bus delay and provides multi‐bit error protection while achieving high‐energy savings. This is achieved by calculating two‐dimensional parities and duplicating all the bits, which provide single error correction and six errors detection. The error correction reduces the performance degradation caused by retransmissions, which when combined with voltage swing reduction, due to its high error detection, high‐energy savings are achieved. The res
... Show MoreIn this study, a new adsorbent derived from sunflower husk powder and coated in CuO nanoparticles (CSFH) was investigated to evaluate the simultaneous adsorption of Levofloxacin (LEV), Meropenem (MER), and Tetracycline (TEC) from an aqueous solution. Significant improvements in the adsorption capacity of the sunflower husk were identified after the powder particles had been coated in CuO nanoparticles. Kinetic data were correlated using a pseudo-second-order model, and was successful for the three antibiotics. Moreover, high compatibility was identified between the LEV, MER, and TEC, isotherm data, and the Langmuir model, which produced a better fit to suit the isotherm curves. In addition, the spontaneous and exothermic nature of the adso
... Show MoreVolatile organic compounds (VOCs) from uninfested and infested broccoli plant samples with green peach aphid
New complexes of the [M(Ura)(Phen)(OH2)Cl2]Cl.2H2O type, where (Ura) uracil ; (Phen) 1,10-phenanthroline hydrate; M (Cr+3 , Fe+3 and La+3) were synthesized from mix ligand and characterized . These complexes have been characterized by the elemental micro analysis, spectral (FT-IR., UV-Vis, 1HNMR, 13CNMR and Mass) and magnetic susceptibility as well the molar conductive mensuration. Cr+3, Fe+3 and La+3- complexes of six–coordinated were proposed for the insulated for three metal(III) complexes for molecular formulas following into uracil property and 1,10-phenanthroline hydrate present . The proposed molecular structure for all metal (III) complexes is octahedral geometries .The biological activity was tested of metal(III) salts, ligands
... Show MoreGlobally, buildings use about 40% of energy. Many elements, such as the physical properties of the structure, the efficiency of the cooling and heating systems, the activity of the occupants, and the building’s sustainability, affect the energy consumption of a building. It is really difficult to predict how much energy a building will need. To improve the building’s sustainability and create sustainable energy sources to reduce carbon dioxide emissions from fossil fuel combustion, estimating the building's energy use is necessary. This paper explains the energy consumed in the lecture building of the Al-Khwarizmi College of Engineering, University of Baghdad (UOB), Baghdad, Iraq. The weather data and the building construction informati
... Show More