The term "tight reservoir" is commonly used to refer to reservoirs with low permeability. Tight oil reservoirs have caused worry owing to its considerable influence upon oil output throughout the petroleum sector. As a result of its low permeability, producing from tight reservoirs presents numerous challenges. Because of their low permeability, producing from tight reservoirs is faced with a variety of difficulties. The research aim is to performing hydraulic fracturing treatment in single vertical well in order to study the possibility of fracking in the Saady reservoir. Iraq's Halfaya oil field's Saady B reservoir is the most important tight reservoir. The diagnostic fracture injection test is determined for HF55using GOHFER software. Models for petrophysics and geology were calibrated using the diagnostic fracture injection test results after the petrophysical and geomechanical parameters of the rock have been determined. The HF55 vertical well, which penetrates the Saady reservoir, has well logs that have been used to evaluate the petrophysical and geomechanical parameters. These estimates have been supported by findings from the diagnostic fracture injection test through the utilization of standard equations and correlations. The findings of the diagnostic fracture injection test, often known as the diagnostic fracture injection test, are very compatible with the findings of the well logs. The diagnostic fracture injection test pre-falloff test event was examined to determine the instantaneous shut-in pressure and fracture gradient. In the meantime, Closure pressure, process zone stress, fracturing fluid efficiency, closure gradient, critical fissure opening pressure, storage correction factor, permeability, and pressure-dependent leak-off coefficient were all determined using the G function on plot. With the help of a specific software, the petrophysical and geomechanical properties of a single vertical well [HF55] was found. Saady B reservoir's upper and lower sections, along with it are therefore predicted to have the full range of petrophysical and geomechanical features. With the use of DFIT analysis, these features serve as the foundation for developing fracturing models.
MRY *Khalid Sh. Sharhan, *Naseer Shukur Hussein, INTERNATIONAL JOURNAL OF DEVELOPMENT IN SOCIAL SCIENCE AND HUMANITIES, 2021
Abstract Background: Kaposi’s sarcoma (KS) is an angioproliferative neoplastic disorder that occurs in different epidemiological forms. Human Herpesvirus type 8 (HHV-8) is established as a causative agent of KS that has been mentioned in textbooks and literature. In the last two decades, KS cases were up searched through many Iraqi medical researches which have been published, but unfortunately, none of which had confirmed this association. Objectives: To assess the association of latent nuclear antigen-1(LANA-1) of HHV-8 among KS patients with clinicopathological parameters and to evaluate if this procedure is valuable for diagnosing this disease through the first immunohistochemical study in Iraq. Methods: This is a clinico-immunohis
... Show Moreنحو تعزيز المشاركة السياسية للطالبات الجامعيات الفلسطينيات
BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr
... Show MoreBackground: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show MoreNumerical investigation has been carried out on heat transfer and friction factor characteristics of copper-water nanofluid flow in a constant heat-fluxed tube with the existence of new configuration of vortex generator using Computational Fluid Dynamics (CFD) simulation. Two types of swirl flow generator: Classical twisted tape (CTT) and Parabolic-cut twisted tape (PCT) with a different twist ratio (= 2.93, 3.91 and 4.89) and different cut depth (= 0.5, 1.0 and 1.5 cm) with 2% and 4% volume concentration
... Show MoreThe solidification process in a multi-tube latent heat energy system is affected by the natural convection and the arrangement of heat exchanger tubes, which changes the buoyancy effect as well. In the current work, the effect of the arrangement of the tubes in a multi-tube heat exchanger was examined during the solidification process with the focus on the natural convection effects inside the phase change material (PCM). The behavior of the system was numerically analyzed using liquid fraction and energy released, as well as temperature, velocity and streamline profiles for different studied cases. The arrangement of the tubes, considering seven pipes in the symmetrical condition, are assumed at different positions in the system, i
... Show MoreConsequence of thermal and concentration convection on peristaltic pumping of hyperbolic tangent nanofluid in a non‐uniform channel and induced magnetic field is discussed in this article. The brief mathematical modeling, along with induced magnetic field, of hyperbolic tangent nanofluid is given. The governing equations are reduced to dimensionless form by using appropriate transformations. Exact solutions are calculated for temperature, nanoparticle volume fraction, and concentration. Numerical technique is manipulated to solve the highly non‐linear differential equations. The roll of different variables is graphically analyzed in terms of concentration, temperature, volume fraction of nanoparticles, axial induced magnetic fie
... Show More