Water supply and distribution networks play an important role in our daily activities. They make a substantial contribution to public health by providing potable water for public consumption and non-potable applications such as firefighters and other purposes such as irrigation. This study used ArcMap 10.8 and WaterGEMS CONNECT Edition update 1 version to create a hydraulic network model to simulate the pipes’ network. Detailed network information, including pipe lengths, layouts, and diameters, was given by the Baghdad Water Department. The TUF-2000H Handheld digital ultrasonic flow meter has been used to measure the water flows in the network’s source nodes. In eight junctions, the model was calibrated by measuring the pressures using the Bourdon gauge at selected junctions. The analysis was based on the steady-state time at the average demand. The analysis results showed that the pressures in the network ranged from 8 to 21 m H2O with a correlation coefficient of 0.988, with a noticeable decrease in pressures in the distant pipes from the sources supplying water to the network. The velocity of the main pipes was within acceptable limits 0.5–2 m/s. While for the internal distribution network, it was noticed that there is an increase in velocity for the main pipes due to low consumption in the lateral pipes.
After the information revolution that occurred in the Western world, and the developments in all fields, especially in the field of education and e-learning, from an integrated system based on the effective employment of information and communication technology in the teaching and learning processes through an environment rich in computer and Internet applications, the community and the learner were able to access information sources and learning at any time and place, in a way that achieves mutual interaction between the elements of the system and the surrounding environment. After the occurrence of the phenomenon of Covid 19, it led to a major interruption in all educational systems that had never happened before, and the disrupt
... Show MoreThe behavior of AC conductivity (σac), loss tangent (tan δ), and relative permittivity (ε′) for composites of PVC-P/graphite electrode waste (GEW) was investigated, and a qualitative explanation was provided as a function of PVC-P weight fractions (0, 5, 10, 15, 20, and 25) wt. percent, temperature (30-90) °C, and frequency (100Hz-2MHz). The behaviors of the composites' ac. conductivity and impedance as a frequency function and temperature have been examined. The permittivity was shown to rise with increasing temperature (Tg). The relative permittivity increased as the GEW filler concentration increased and was highest in the low-frequency range; nevertheless decreased as the frequency increased.