Preferred Language
Articles
/
4xftUo4BVTCNdQwCAEEV
Measurement radon concentrations in samples for drinking water
...Show More Authors

The principal forms of radiation dosage for humans from spontaneous radiation material are being recognized as radon and its progenitors in the interior environment. Radiation-related health risks are caused by radon in water supply, which can be inhaled or ingested. Materials and Methods: The solid-state CR-39 nuclear trace detectors method was using in this research for measuring accumulation of radioactivity in water supply in different locations of Iraq's southwest corner of Baghdad. In Baghdad district, 42 samples were selected from 14 regions (3 samples out of each region) and put in dosimeters for 50 days. Results: The mean radon concentration was 49.75 Bq/m3, that is lower than the internationally recognized limit of 1100 Bq /m3. The total absorbed dose in micro sieverts each year (mSv/y) and concentration about alpha energy has be estimated. Within the area under study, the linear relation between annual effective dose in (mSv/y) and radon concentration has been established. Conclusion: According on the, findings radon concentrations in drinking water supplies are below than EPA's and WHO's recommended levels.

Scopus Crossref
View Publication
Publication Date
Thu Apr 20 2023
Journal Name
Maaen Journal For Medical Sciences
Evaluation of heated cure acrylic immersed in ozonated water
...Show More Authors

Background: Denture cleansing is an important step that can prevent the spread of infection and improve a patient's health, the durability of the dentures, and the overall quality of life; therefore, it is necessary to choose a suitable cleanser that, in addition to being effective, does not have an unfavorable effect on the qualities of the denture base resin itself when used for an extended period. Aim: This research aims to assess the effects of ozonated water on the surface roughness and hardness of heat-cured acrylic resin by immersion technique. Materials: Sixty bars shapemade of heat-cured acrylicweremanufactured.Thirty samples for every test, including: (surface hardness and surface roughness). Then, these samples were divided into

... Show More
View Publication
Crossref
Publication Date
Wed Jul 05 2017
Journal Name
Https://www.researchgate.net/journal/international-journal-of-science-and-research-ijsr-2319-7064
Evaluation of Water Quality using Bhargava Water Quality Index Method and GIS, Case Study: Euphrates River in Al-Najaf City
...Show More Authors

ENGLISH

Crossref (1)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Water Quality Assessment for Tigris River Through Salah Al-Din Province, Iraq Using Remote Sensing Techniques
...Show More Authors

water quality assessment is still being done at specific locations of major concern. The use of Geographical Information System (GIS) based water quality information system and spatial analysis with Inverse Distance Weighted interpolation enabled the mapping of water quality indicators along Tigris river in Salah Al-Din government, Iraq. Water quality indicators were monitored by taking 13 river samples from different locations along the river during Winter season year 2020. Maps of 10 water quality indicators. This meant that the specific water quality indicator and diffuse pollution characteristics in the basin were better illustrated with the variations displayed along the course of the river than conventional line graphs. Creation of

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Dec 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Design and Construction of Electrical Magnate to Study its Efficiency and the Optimum Parameters to Produce Alkaline Magnetic Water and Treating the Sea Water to be Suitable for Irrigation
...Show More Authors

Abstract

Electrical magnate  was designed and constructed,  the optimum Magnetic flux  and the effect of time on the physical properties of the alkaline (magnetic water) produced from the bottled drinking water [the total dissolved solids (TDS) or the electrical conductivity, and pH] were studied, to simulate ZamZam water in Mekka Saudi Arabia. Also, the efficiency of magnetic field from this designed electrical magnate in decreasing the TDS of sea water (of 1500 ppm NaCl Content), to convert it to water suitable for irrigation (TDS<1000 ppm) was investigated in this work.The results show that the magnetic flux from our designed electrical magnate in the range of (0.013- 0.08) Tesla and 30 minut

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 27 2020
Journal Name
Iraqi Journal Of Science
Water Quality of Groundwater in Selected Wells in Zubair Area, Basra City
...Show More Authors

Zubair area is located at the extreme part of the south of Iraq and represents the southern part of the western desert, bounded by the north latitudes 30o05'-30o25' and east longitudes 47o30'- 47â—¦55'. Groundwater is a major natural resource in the study area because no perennial river exists. Groundwater from twenty wells in the study area were analyzed in order to determine some of chemical variables such as major cations (Ca+2, Mg+2 ,Na+ ,K+ ) and major anions (CL- ,SO4-2 ,HCO3- ,CO3-2 ,NO3-) along with several physical variables such as hydrogen ion concentration (pH) , total dissolved solids (TDS), and electrical conductivity (EC).  Hydro-chemical analysis showed that the groundwater of the study area is excessively minera

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Iraqi Journal Of Science
Measurement of the radioactivity in raw materials used in the ceramic industry in AL-Ramadi ceramic factory using (HPGe) detector
...Show More Authors

In this research, we have measured specific activity concentrations in five samples for raw materials used in ceramic industry in AL-Ramadi ceramic factory by using (HPGe) detector. The results have shown that, the average specific activity, for 238U, 232Th and 40K are equal to (18.300±6.4 Bq/kg), (17.988±6.1 Bq/kg), (167.952±63.5 Bq/kg), respectively.  In order to assess the radiological hazards of the radioactivity in samples, radium equivalent activity, absorbed gamma dose rate, indoor and outdoor annual effective dose rates, gamma Index and both (external and internal) hazard effects have been calculated. All results were found to be less than the allowed global limit given by (UNSCEAR, 2000).

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 30 2022
Journal Name
Iraqi Journal Of Science
Optical Emission Spectroscopy for Studying Fe Plasma Parameters Produced by Exploding Wire Technique in Carbon Nanotubes - Water Colloid
...Show More Authors

     The goal of this work is to study plasma parameters for Fe plasma generated by exploding wire (EEW) in carbon nanotubes-water colloid with three current values (50, 100 and 150)A. In this research, the plasma electron temperature (Te), the electron density (ne), electron density (ne), plasma frequency(f p), Debye length (λD) and Debye number (ND) were  found for Fe produced by Arc discharge plasma. Boltzmann plot was used to calculate the plasma electron temperature (Te);electron density (ne) was calculated from  Stark broadening. It was found that the electron temperature values increased from (0.4

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Concentrations of selected elements in saliva among a group of adolescent girls in relation to severity of caries and selected salivary parameters
...Show More Authors

Background: Saliva is one of the most important etiological host factors in relation to dental caries. It affects the carious process by its organic and inorganic constituents; in addition to its physiological functions as (flow rate, pH and buffer capacity). The aims of this study were to determine the concentrations of major elements (calcium and phosphorus) and trace elements (ferrous iron, nickel, chromium and aluminum) in saliva among a group of adolescent girls, and to explore the relation of these elements, flow rate and pH with dental caries. Material & Methods: The study group consisted of 25 girls with an age of 13-15 years old. Dental caries was diagnosed by both clinical and radiographical examinations following the criteria of

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Influence of water absorption on fatigue behavior for chopped and woven-glass-fibers-reinforced PMMA denture
...Show More Authors

The influence of fiber orientation and water absorption on fatigue crack growth resistance for cold cure acrylic (PMMA) reinforced by chopped and woven -glass-fibers were investigated. A weight of 2 g for chopped fibers and the same weight for woven -glass-fibers (one layer) were used to prepare samples. Some of these samples would storage in dry condition; the others were immersed in water for 15 days. Fatigue test was carried out. The results shows that, for PMMA, the initial bending stress for dry specimen was 3.392 N/cm2 and the number of cycles were 1364, the initial bending stress for wet samples was 4.20 N/cm2, and the number of cycles was 2411. The samples would cut in two pieces because of the cracks would propagated fast during

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
PHYSIO-CHEMICAL ANALYSIS OF SAMPLES OF SOIL SELECTED FROM DIFFERENT AGRICULTURE AREAS FROM AL-NAJAF: PHYSIO-CHEMICAL ANALYSIS OF SAMPLES OF SOIL SELECTED FROM DIFFERENT AGRICULTURE AREAS FROM AL-NAJAF
...Show More Authors

The twelve samples of agricultural soils from four regions in Al-Najaf governorate with sampling plant with soil. Physical properties of the soil where studied, such as electrical conductivity ranged from (136.33-1070.00)μS/cm-3, and moisture which ranged between the values (0.39-36.48)%. The chemical analysis of the soil have included the proportion of calcium carbonate the ratio between (44.00-48.00%) has been observed increasing amounts of calcium carbonate in surface models. The pH where results indicate that pH values ​​were close to study models ranged between (6.88-7.42) these values ​​generally within the normal range for the measured pH values ​​of the Iraqi soil. The amount of gypsum ranged betwe

... Show More
View Publication Preview PDF