Preferred Language
Articles
/
4xftUo4BVTCNdQwCAEEV
Measurement radon concentrations in samples for drinking water
...Show More Authors

The principal forms of radiation dosage for humans from spontaneous radiation material are being recognized as radon and its progenitors in the interior environment. Radiation-related health risks are caused by radon in water supply, which can be inhaled or ingested. Materials and Methods: The solid-state CR-39 nuclear trace detectors method was using in this research for measuring accumulation of radioactivity in water supply in different locations of Iraq's southwest corner of Baghdad. In Baghdad district, 42 samples were selected from 14 regions (3 samples out of each region) and put in dosimeters for 50 days. Results: The mean radon concentration was 49.75 Bq/m3, that is lower than the internationally recognized limit of 1100 Bq /m3. The total absorbed dose in micro sieverts each year (mSv/y) and concentration about alpha energy has be estimated. Within the area under study, the linear relation between annual effective dose in (mSv/y) and radon concentration has been established. Conclusion: According on the, findings radon concentrations in drinking water supplies are below than EPA's and WHO's recommended levels.

Scopus Crossref
View Publication
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
ANALYTICAL SOLUTION OF UNSATURATED SOIL WATER FLOW FROM A POINT SOURCE
...Show More Authors

Water flow into unsaturated porous media is governed by the Richards’ partial differential equation expressing the mass conservation and Darcy’s laws. The Richards’ equation may be written in three forms,where the dependent variable is pressure head or moisture content, and the constitutive relationships between water content and pressure head allow for conversion of one form into the other. In the present paper, the “moisture-based" form of Richards’ equation is linearized by applying Kirchhoff’s transformation, which
combines the soil water diffusivity and soil water content. Then the similarity method is used to obtain the analytical solution of wetting front position. This exact solution is obtained by means of Lie’s

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
study the effects of the polluted waste water on the environment
...Show More Authors

to study the discribrion and the pollution in the environment in the south of baghdad samples of waste water from industrail units using the mercury in its process also

View Publication Preview PDF
Publication Date
Sun Apr 26 2020
Journal Name
Iraqi Journal Of Science
Evaluation of the Pollution Elements at Samara Water Table – Iraq
...Show More Authors

Underground water is extracted by wells that are connected through underground canals. Thus, the levels of pollutant elements in ground water could be evaluated directly from water samples collected from the wells. This study was conducted in the city of Samara / Salah-Aldeen province – Iraq. The samples were taken from 29
wells within the study area for the period 2012-2014 with a supervision from the General Authority for Groundwater / the Iraqi Ministry of Water Resources. GIS technology was adopted to calculate the pollution elements at Samara water table. The concentrations of chemical elements [K, Na, Mg, Cl, Ca] and compounds [SO4, HCO3] were manipulated and calculated for the entire area. The results of laboratory analy

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Desalination of Highly Saline Water Using Direct Contact Membrane Distillation (DCMD)
...Show More Authors

In this work, laboratory experiments were carried out to verify direct contact membrane distillation system’s performance in highly saline water desalination. The study included the investigation of various operating conditions, like feed flow rate, temperature and concentration of NaCl solution and their impact on the permeation flux were discussed. 16 cm2 of a flat sheet membrane module with commercial poly-tetra-fluoroethylene (PTFE) membrane, which has 0.22 μm pore size, 96 µm thickness and 78% average porosity, was used. A high salt rejection factor was obtained greater than 99.9%, and the permeation flux up to 17.27 kg/m2.h was achieved at 65°C for hot feed side and 20°C for cold side stream.

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of dyes from polluted water by adsorption on maize cob
...Show More Authors

This research aimed to examine the effect of concentration of dyes stuff, contact time, temperature and ratio of adsorbent weight in (gm) to volume of solution in (ml) on the percentage removal. Two dyes were used; direct blue 6 and direct yellow and the adsorbent was the maize cob. Batch experiments were performed by contacting different weights of adsorbent with 50 ml of solution of desired concentration with continuous stirring at various temperatures. The percentage of removal was calculated and the maximum percentage of removal was 80%. And as the concentration of solution, contact time, temperature and the ratio of adsorbent to volume of solution increase the percentage of removal increase.

View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Green Engineering
Assessment and modelling of water quality along Al-Gharraf River (Iraq)
...Show More Authors

Scopus (6)
Scopus
Publication Date
Mon Jul 31 2017
Journal Name
Journal Of Engineering
Assessment of Water Clarity within Dokan Lake Using Remote Sensing Techniques
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Stabilization of Al-Rustamiya Waste Water Treatment Plant Sludge Using Lime
...Show More Authors

A study was performed to evaluate heavy metals removal from sewage sludge using lime. The processes of stabilization using alkaline chemicals operating on a simple principle of raising pH to 12 or higher, with sufficient mixing and suitable contact time to ensure that immobilization can reduce heavy metals. A 0.157 m3 tank was designed to treat Al-Rustemeyia wastewater treatment plant sludge. Characteristics of raw sludge were examined through two parameters: pH and heavy metal analysis. Different lime doses of (0- 25) g CaO/100 g sludge were mixed manually with raw sludge in a rotating drum. The samples were analyzed two hours after mixing. pH and heavy metals results were compared with EPA and National Iraqi Stand

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Mar 19 2022
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Mass Ratio on Phytoremediation of Nickel Contaminated Water
...Show More Authors

 

Water pollution is one of the global challenges that the society must address in the 21st century aiming to improve the water quality, reduce human pollutants and ecosystem health impacts. In phytotoxicity test, the plant of Iresine herbstii was exposed to remove nickel from simulated wastewater using two different ratios (mass of plant to the mass of nickel) (,Rp/Ni) for 21 days with sub-surface batch system. During the exposure period, the removal of Ni concentrations (2, 5 and 10 mg/L) for two mass ratio (2,800 and 34,000) were (83.6%, 77.2%, 78.0%) and (86.8%, 97% and 95.6%), respectively. final result of the rate was found that the highest removal occurred, 97%, at a mass ratio of 34,000 and

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
A Study Of Corrosion Behavior Of Low Carbon Steel In Acidic And Basic Washing Water Of Crude Oil Solution At Different Temperatures
...Show More Authors

The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were

... Show More
View Publication Preview PDF
Crossref