Preferred Language
Articles
/
4xePeI0BVTCNdQwC-xQ0
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis with the quoted value using the standard addition method. It can be noticed that there was no significant differences between the newly developed method and the quoted value by the manufacturers companies. It indicates clearly that the new method can be used for the assessment as well as the method adopted by the manufactures companies that can be described.

View Publication
Publication Date
Mon Feb 01 2010
Journal Name
Food Chemistry
Determination of aflatoxins in animal feeds by HPLC with multifunctional column clean-up
...Show More Authors

A reversed-phase HPLC method with fluorescence detection for the determination of the aflatoxins B1, B2, G1 and G2 in 42 animal feeds, comprising corn (16), soya bean meal (8), mixed meal (13), sunflower, wheat, canola, palm kernel, copra meals (1 each) was carried out. The samples were first extracted using acetonitrile:water (9:1), and was further cleaned-up using a multifunctional column. Optimum conditions for the extraction and chromatographic separation were investigated. By adopting an isocratic chromatographic system using a mobile phase comprising acetonitrile:methanol:water (8:27:65, v/v/v), the separation of the four aflatoxins was possible within 30 min. Recoveries for aflatoxins B1, B2, G1 and G2 were 98 ± 0.7%, 95 ± 1.0%, 94

... Show More
View Publication
Scopus (118)
Crossref (104)
Scopus Clarivate Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Using of Laser Therapy in the Treatment of Patients With Plantar Fasciitis
...Show More Authors

Background: planter fasciitis is a common condition
seen in adults and sport men, it is characterized by dull
pain in the heel, especially when getting up and
standing on the foot in the morning or after sitting for a
long time.
Recently low level laser therapy is used as a method of
treatment.
Objective: to evaluate the benefit of laser therapy in
treatment of planter fasciitis.
Methods: Out of twenty five patients with planter
fasciitis exposed to laser therapy. Laser used is (diode
type) given in two cessions per week for four weeks,
time for each cession is about (12 minutes).
Results: complete recovery seen in (32%) of patients,
moderate improvement in (16%), mild improvement in
(24%), no

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Drilling of FR-4 Composite Materials Using Single Pulse of Nd:YAG Laser
...Show More Authors

Laser drilling is capable of producing small, precisely positioned holes with high degree of reproductively. In this paper , IR millisecond Nd:YAG single pulsed laser was used to determine the effect of laser parameters on the drilled hole of the glass - fiber reinforced epoxy composite FR-4 sample of 2 mm in thickness . The type of laser source was GSI lumonics JK760TR Series laser 1.064μm system in a CNC cabin. The JK760TR series has a 0.3-50ms pulse length and a maximum repetition rate 500Hz with an average power of 600W. The investigation of single pulse laser drilling in this paper was based on theoretical and experimental solutions. In single pulse technique, the investigation included focal plane position fpp, pulse shap

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Spot Welding of Dissimilar Metals Using an Automated Nd:YAG Laser System
...Show More Authors

An assembled pulsed Nd:YAG laser-robot system for spot welding similar and dissimilar metals is presented in this paper. The study evaluates the performance of this system through investigating the possibility and accuracy of executing laser spot welding of 0.2 mm in thickness stainless steel grade AISI302 to 0.5 mm in thickness low carbon steel grade AISI1008. The influence of laser beam parameters (peak power, pulse energy, pulse duration, repetition rate, and focal plane position on the final gained best results are evaluated. Enhancement of the experimental results was carried by a computational simulation using ANSYS FLUENT 6.3 package code.

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Scar Using CO2 Laser with or Without Corticosteroid
...Show More Authors

CO2 Laser (10600nm) is the recent method in the management of challenging skin scar resulting from trauma, burn and surgical wound. The aim of this study was to evaluate the efficacy & safety of fractional CO2 laser (10600nm) in treatment of skin scar. Materials and Methods:Twenty patients with different types of scars treated with fractional CO2 (10600nm) laser, (10 patients) were given additional intralesional Triamcinolone. Results: All of the twenty patients included in this study showed some sort of improvements in scar texture, height and pliability and all of the ten patients who received intralesional Triamcinolone after laser show complete satisfaction. Conclusion:Fractional CO2 (10600nm) laser can be used as alternative, ef

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Generation of 629 nm Pulsed Laser Using an Optical Parametric Amplifier
...Show More Authors

The main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.

View Publication Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
He-Ne Laser Irradiation Encourages reparative processes After cartilage loss in New Zealand rabbits
...Show More Authors

Many therapeutic methods used to encourage reparative processes of cartilage and accelerate their healing such as drugs, magneto-laser and so on. Twenty four adult New Zealand rabbits used in this study. They were divided in to two groups; control and treaded with He –Ne laser. A square skin flap done on the medial aspect of both auricles followed by pealing a square piece of cartilage from the auricle then the flaps sutured .The site of the operation in the rabbits of the treated group were irradiated with He –Ne laser 5mw power for seven days began after the operation directly. 3 rabbits from each group used for collection of specimens for histopathological examination at the 1, 2, 4 & 6 weeks post the operation. Significant

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Hydrology
Complementary data-intelligence model for river flow simulation
...Show More Authors

View Publication
Crossref (87)
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
Treatment of Striae Grvidarum as a Type of Striae Distensae Using Long Pulsed Nd:YAG Laser (1064nm) and Fractional CO2 Laser (10600nm)
...Show More Authors

Striae distensae SD or stretch mark are frequent skin lesion that cause considerable aesthetic concern. The 1064nm long pulsed Nd:YAG Laser has been used to promote an increase in dermal collagen and is known to be a Laser that has a high affinity to vascular chromphores. Also by using fractional CO2 Laser 10600nm as an effective modality in treatment of striae distensae SD. It works to stimulate fibroblast and enhance Collagen formation, which is important for newly generated skin tissue.

Objectives: This study aims to verify the efficacy of long pulsed Nd: YAG Laser (1064nm) in the treatment of immature striae distensae (SD) and the efficacy of C02 fractional Laser (10600nm) in treatment o

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Antibacterial Photodynamic Effect of 532 nm Diode-Pumped Solid State and 650 nm Diode Lasers on Methicillin Resistant Staphylococcus Aureus in Vitro
...Show More Authors

The photodynamic inactivation against Methicillin-resistant Staphylococcus aureus using two different lasers, 532 nm diode pumped solid state laser (DPSS) in combination with safranin O and 650 nm diode laser in combination with methylene blue was investigated in the present work. A hundred swab samples were collected from patients with burn and wound infections admitted to two hospitals in Baghdad (Specialized Burns Hospital in Medical City and Al Imamein Al Jwadein Medical City Hospital) from December 2015 to February 2016 Antimicrobial susceptibility was performed by using Kirby- Bauer method. The irradiation experiments included four groups; a control group, a photosensitizer only group, a laser irradiation only group and a laser irr

... Show More
View Publication Preview PDF