The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis with the quoted value using the standard addition method. It can be noticed that there was no significant differences between the newly developed method and the quoted value by the manufacturers companies. It indicates clearly that the new method can be used for the assessment as well as the method adopted by the manufactures companies that can be described.
Background: lip lengthening procedure is one of the surgical options for the correction of gummy smile in patients with short upper lip. Methods: A comparative clinical study was conducted on 15 patients requiring lip lengthening procedure for the esthetic correction of excessive gingival exposure with gummy smile. Scalpel was used in seven patients and diode laser in the remaining eight patients. Under infiltration anesthesia, about one cm strip of mucosa was excised at the vestibular depth and the mucosa of the lip was sutured to the alveolar mucosa. Results: The diode laser group demonstrated less postoperative pain and swelling. Regarding postoperative ecchymosis, three patients in the scalpel group developed ecchymosis and no cases
... Show MoreAbstract Background: Crown lengthening is a surgical procedure that apically positions the gingival edge and/or removes supporting bone in order to increase the amount of supra gingival tooth structure for restorative or cosmetic purposes.
The objective of the study: The purpose of this study was to evaluate the efficacy of the 940nm diode laser in esthetic crown lengthening surgery through clinical observations, patient questionnaires, clinical photographs, and gingival healing following gingival operations. Material and methods: In this randomized clinical trial, 16 patients (11 females and 5 males) had their crowns surgically lengthened using a diode laser (940 nm) in continuou
... Show MoreSummary
The subject ( meaning of added verbs) is one of the main subjects
which study in morphology since in Arabic language. It is include the meaning
of each format, and the increased meaning occurred by this increment in the
verbs.
The (strain) is one of very important meaning in this subject, it takes a
wide area of morphology studies, and interesting of scientists and
researchists.
There are two famous formats for this meaning; (infa la انفع
ل ), and (ifta
la افتع
ل ). Also There are another formats for the same meaning, but less than
the first two in use, they are; (taf ala تفعّ
ل ), (tafa ala تفاع
ل ), (taf lala ) ,(تفعل
ل
ifanlala افعنلل ), (ifanla .(
Abstracts:
Background: The oral cavity is a complex environment, both structurally and functionally, the hard and soft tissues are in close a proximity. Oral tissues subjected to wear throughout the life, that threatened the vitality of the pulp or increase the sensitivity of dentinal tubules. One of the common dental problems is loss of enamel or cementum, which stimulate the nerve ending in or near the pulp and manifested as pain sensation. Aim of the study: This study had done to evaluate the effects of 980nm diode Laser in diameters reduction of exposed dentinal tubules analyze the results and morphological changes of irradiated dentine surface by FE-SEM (field emission scann
... Show MoreA new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .
There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one
... Show MoreThe reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,
... Show MoreAn optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination
... Show MoreIn this paper, new approach based on coupled Laplace transformation with decomposition method is proposed to solve type of partial differential equation. Then it’s used to find the accurate solution for heat equation with initial conditions. Four examples introduced to illustrate the accuracy, efficiency of suggested method. The practical results show the importance of suggested method for solve differential equations with high accuracy and easy implemented.