Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concentration, basic medium, flow rate, sample volume, purge time, and delay coil have been investigated. The dynamic range of MFA was 0.2 to 2 mmol.L-1; 0.5 to 2.3 mmol.L-1 with linearity percentage (% r2) 98.92 and 99.83%, for Rh-6G and CLB, respectively. Limit of detection at a minimum concentration in calibration curve 189.34 and 199.89 ng/sample, for Rh-6G and CLB, respectively. The comparison of developed methods with the classical method (UV-vis spectrophotometry) was achieved. The proposed methods were successfully applied for the determination of MFA in the pharmaceutical samples and can be used as an alternative method.
In this paper, preliminary test Shrinkage estimator have been considered for estimating the shape parameter α of pareto distribution when the scale parameter equal to the smallest loss and when a prior estimate α0 of α is available as initial value from the past experiences or from quaintance cases. The proposed estimator is shown to have a smaller mean squared error in a region around α0 when comparison with usual and existing estimators.
The mobile phone is widespread all over the world. This technology is one of the most widespread with more than five billion subscriptions making people describe this interaction system as Wireless Intelligence. Mobile phone networks become the focus of attention of researchers, organizations and governments due to its penetration in all life fields. Analyzing mobile phone traces allows describing human mobility with accuracy as never done before. The main objective in this contribution is to represent the people density in specific regions at specific duration of time according to raw data (mobile phone traces). This type of spatio-temporal data named CDR (Call Data Records), which have properties of the time and spatial indications for th
... Show MorePre-eclampsia complicates 2-8% of all pregnancies and it is one of the leading causes of maternal mortality and pre-term delivery in the world. Unfortunately, there is scarcity of documents discussing the circulating level of several essential trace elements in Pre-eclampsia patients in Baghdad especially in the last trimester of the pregnancy. The present study was designed to quantitative evaluation the whole blood concentration of two trace elements, copper (Cu), and iron(Fe), in pre-eclamptic women in the third trimester of pregnancy. The study was conducted on 18 Pre-eclamptic pregnant women as patients group with clinical detected high blood pressure ≥140/90 mmHg and 13 normotensive pregnant women as control group from Al-Alwiya
... Show MoreIn this research, salbutamol sulphate (SAS) has been determined by a simple, rapid and sensitive spectrophotometric method. Salbutamol sulphate in this method is based on the coupling of SAS with diazotized ρ- bromoaniline reagent in alkaline medium of Triton X-100 (Tx) to form an orange azo dye which is stable and water-soluble. The azo dye is exhibiting maximum absorption at 441 nm. A 10 - 800 µg of SAS is obeyed of Beer's law in a final volume of 20 ml, i.e., 0.5- 40 ppm with ε, the molar absorptivity of 48558 L.mol-1.cm-1 and Sandell's sensitivity index of 0.01188 µg.cm-2. This new method does not need solvent extraction or temperature control which is well applied to determine SAS in d
... Show MoreA new method for determination of allopurinol in microgram level depending on its ability to reduce the yellow absorption spectrum of (I-3) at maximum wavelength ( ?max 350nm) . The optimum conditions such as "concentration of reactant materials , time of sitting and order of addition were studied to get a high sensitivity ( ? = 27229 l.mole-1.cm-1) sandal sensitivity : 0.0053 µg cm-2 ,with wide range of calibration curve ( 1 – 9 µg.ml-1 ) good stability (more then24 hr.) and repeatability ( RSD % : 2.1 -2.6 % ) , the Recovery % : ( 98.17 – 100.5 % ) , the Erel % ( 0.50 -1.83 % ) and the interference's of Xanthine , Cystein , Creatinine , Urea and the Glucose in 20 , 40 , 60 fold of analyate were also studied .
Klebsiella pneumoniae is a severe opportunistic strain of enteric bacteria that is a major cause of urinary tract infection and pneumonia. This study was conducted in Baghdad City during September 2020-November 2020 on 50 clinical samples of urine, vaginal, sputum, wound swabs, ear swabs, and burn swabs. strains were identified using the VITEK-2 compact system and tested in K. pneumoniae terms of susceptibility to various antimicrobial drugs by Kirby-Bauer test. The isolates were more predominant in the females (56%) compared to males (44%). The antibiotic resistance rate of varied among different isolated clinical sample sources. K. pneumoniae K. pneumoniae isolated from different clinical specimens differed with respect
... Show MorePseudomonas aeruginosa has variety of virulence factors that contribute to its pathogenicity. Therefore, rapid detection with high accuracy and specificity is very important in the control of this pathogenic bacterium. To evaluate the accuracy and specificity of Polymerase Chain Reaction (PCR) assay, ETA and gyrB genes were targeted to detect pathogenic strains of P. aeruginosa. Seventy swab samples were taken from patients with infected wounds and burns in two hospitals in Erbil and Koya cities in Iraq. The isolates were traditionally identified using phenotypic methods, and DNA was extracted from the positive samples, to apply PCR using the species specific primers targeting ETA, the gene encoding for exotoxin A, and gyrB gene. The res
... Show MoreThe aim of this work was to estimate the concentrations of natural and artificial nuclides in some fertilized and unfertilized plant samples. These samples were collected and prepared in a petri dish for the measurements using gamma spectroscopy. The average values of 238U, 232Th, 40K, and 137Cs for the unfertilized plant samples were (11.964 ± 3.226, 8.273 ± 2.639, 402.436 ± 18.099, and 2.761 ± 1.613) respectively, and for the fertilized plant samples were (30.434 ± 5.282, 22.584 ± 4.620, 711.332 ± 25.806, and 6.986 ± 2.542) respectively. The average values of radiological hazard indices, Raeq, D, D for 137Cs, (AEDE)in, (AEDE)out, Iγ, Hin, and Hout for the unfertilized plant samples were (54.782 ± 7.216, 27.306, 0.469, 0.
... Show MoreTwelve cigarette tobacco samples of various brands and origins were gathered from local markets of Iraq. . The CRn was determined utilizing CR-39 track detectors which were exposed to the various brands of cigarettes tobacco for 45 days. The results demonstrated that the highest value of 222Rn concentration was )157 Bq/m3( in Macbeth cigarette sample of Brazilian origin and the lowest value of CRn was (76.3 Bq/m3 (in Sumer cigarette sample of Iraqi origin,with an average value of (106.53±22.3 Bq/m3). The outcomes have demonstrated that cigarettes of a Brazilian origin contain higher CRn tha
... Show MoreA numerical method is developed to obtain two-dimensional velocity and pressure distribution through a cylindrical pipe with cross jet flows. The method is based on solving partial differential equations for the conservation of mass and momentum by finite difference method to convert them into algebraic equations. This well-known problem is used to introduce the basic concepts of CFD including: the finite- difference mesh, the discrete nature of the numerical solution, and the dependence of the result on the mesh refinement. Staggered grid implementation of the numerical model is used. The set of algebraic equations is solved simultaneously by “SIMPLE” algorithm to obtain velocity and pressure distribution within a pipe. In order to
... Show More