Preferred Language
Articles
/
4hbJAYsBVTCNdQwCycZR
Diagnostic study of the most important fungal infections associated with some inflammatory bowel disease in Iraqi patients
...Show More Authors

The current study aimed to isolate and diagnose the fungi associated with the inflammatory bowel disease patients with 150 samples distributed between 50 samples from Crohn's patients and 50 samples from ulcerative colitis patients, 50 control from Al-Kindy Al Teaching Hospital in Baghdad, Baghdad. Five types of yeast were isolated and identified, namely C. albicans, C.glabarta, Tropicales, C. parapsilosis, C. and C., krusi C. parapsilosis and.and Aspergillus, Penicillium, Muocer, Rhizopous, Saccharomycosis, and Cryptococcus, The results indicated the dominance of Candida spp. In crohn’s disease, the frequency of isolated Candida albicans was 24 (58.54%), Candida glabrata 11 (26.86%), Candida tropicalis 5 (12.2%) and Candida krusi was 1 (2.44%); the statistical analysis detected a significant differences (<0.001) in the frequency of isolated Candida in this disease and the higher ratio was with Candida albicans On the other hand, the frequency of candida species in Ulcerative colitis patients was as following: Candida albicans 15 (45.45%), Candida glabrata 6 (18.18%), Candida tropicalis 11 (33.3%) and Candida parapsilosis i 1 (3.03%) The results found that there is a significant differences between the ratio of the isolated Candida species and the high frequency was with Candida albicans. They were confirmed by PCR device, The C. albicans showed the ability to form a Grem tube and Chlamydospore formation. Cultivation on the differential medium, chromo agar, showed that the yeast of C. albicans in a light green color, C.tropicalis in a metallic blue, and C.parapsilosis in a creamy white color as the C .krusei was light pink in color, while C.glabrata was pinkish-purple in color. Isolation and diagnosis of these species have been confirmed by the Vitek2 Compact System. Four types of antifungal agents fungi Nystatin Clotrimazole Fluconazole Itraconazole. The results of the PCR using the fungi starter pair (ITS1, ITS4) showed that they produced different molecular sizes ranging from (510-870) bp

Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
Correlation between Seminal Parameters and Response to InVitro Sperm Activation According to Age and Type of Infertility
...Show More Authors

This study was aimed to investigate the effect of sperm parameters on the response to in vitro sperm activation (ISA) and to compare sperm parameters according to the age and type of infertility.
One hundred twenty-eight subjects employed in this study, with age range (18-49) years and duration of infertility (1-28) years. From each subjects semen sample was obtained and seminal fluid analysis (SFA) was done. Simple medium for assisted reproductive techniques; (SMART) was used for in vitro sperm activation by direct swim-up technique and centrifugation Swim-Up technique. Sperm concentration, sperm motility (%), sperm grade activity (%), normal sperm morphology (%) and sperm agglutination (%) were assessed. Crude data were statisticall

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Photochemistry And Photobiology A: Chemistry
Improved photocatalytic degradation of methyl violet dye and pathogenic bacteria using g-C3N4 supported phosphotungstic acid heterojunction
...Show More Authors

Scopus (37)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2019
Journal Name
Environmental Technology &amp; Innovation
Biomineralization based remediation of cadmium and nickel contaminated wastewater by ureolytic bacteria isolated from barn horses soil
...Show More Authors

View Publication
Scopus (86)
Crossref (76)
Scopus Clarivate Crossref
Publication Date
Sun Apr 25 2021
Journal Name
Egyptian Journal Of Chemistry
Indirect spectrophotometric determination of Mebendazole using n-bromosuccinimide as an oxidant and tartarazine dye as analytical reagent
...Show More Authors

View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
Forward and Reverse Osmosis Process for Recovery and Re-use of Water from Polluted Water by Phenol
...Show More Authors

The research aims to apply the novel forward osmosis (FO) process to recover pure water
from contaminated water. Phenol was used as organic substance in the feed solution, while sodium
chloride salt was used as draw solution. Membranes used in the FO process is the cellulose
triacetate (CTA) and polyamide (thin film composite (TFC)) membrane. Reverse osmosis process
was used to treatment the draw solution, the exterior from the forward osmosis process. In the FO
process the active layer of the membrane faces the feed solution and the porous support layer faces
the draw solution and this will show the effect of dilutive internal concentration polarization and
concentrative external concentration polarization.
In th

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Molecular Docking, Synthesis, characterization and preliminary cytotoxic evaluation of new 1, 3,4-Thiadiazole derivatives as EGFR inhibitors
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Lab on-a-chip-based, an integrated microfluidic device lo-cost, rapid, and sensitive analysis of Augmentin
...Show More Authors

Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Ieee Access
A Direct Solution Scheme for Wide-Angle Electromagnetic Scattering Problems Using Compressive Sensing-Based Method of Moments
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Wed Jul 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Theoretical Investigation of Charge Transfer Dynamics from Sensitized Molecule D35CPDT Dye to SnO_2 and TiO_2 Semiconductor
...Show More Authors

In this research, the dynamics process of charge transfer from the sensitized  D35CPDT dye to tin(iv) oxide( ) or titanium dioxide (  ) semiconductors are carried out by using a quantum model for charge transfer. Different chemical solvents Pyridine, 2-Methoxyethanol. Ethanol, Acetonitrile, and Methanol have been used with both systems as polar media surrounded the systems. The rate for charge transfer from photo-excitation D35CPDTdye and injection into the conduction band of  or  semiconductors vary from a  to  for system and from a   to  for the system, depending on the charge transfer parameters strength coupling, free energy, potential of donor and acceptor in the system. The charge transfer rate in D35CPDT /  the syst

... Show More
View Publication
Crossref
Publication Date
Tue Jun 21 2022
Journal Name
Peerj Computer Science
Performance evaluation of frequency division duplex (FDD) massive multiple input multiple output (MIMO) under different correlation models
...Show More Authors

Massive multiple-input multiple-output (massive-MIMO) is considered as the key technology to meet the huge demands of data rates in the future wireless communications networks. However, for massive-MIMO systems to realize their maximum potential gain, sufficiently accurate downlink (DL) channel state information (CSI) with low overhead to meet the short coherence time (CT) is required. Therefore, this article aims to overcome the technical challenge of DL CSI estimation in a frequency-division-duplex (FDD) massive-MIMO with short CT considering five different physical correlation models. To this end, the statistical structure of the massive-MIMO channel, which is captured by the physical correlation is exploited to find sufficiently

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref