Preferred Language
Articles
/
4YYmK4YBIXToZYALen1N
A Review of Historical Studies for Water Saturation Determination Techniques
...Show More Authors

Water saturation is the most significant characteristic for reservoir characterization in order to assess oil reserves; this paper reviewed the concepts and applications of both classic and new approaches to determine water saturation. so, this work guides the reader to realize and distinguish between various strategies to obtain an appropriate water saturation value from electrical logging in both resistivity and dielectric has been studied, and the most well-known models in clean and shaly formation have been demonstrated. The Nuclear Magnetic Resonance in conventional and nonconventional reservoirs has been reviewed and understood as the major feature of this approach to estimate Water Saturation based on T2 distribution. Artificial intelligence has recently been used to predict water saturation and other parameters in the reservoir characterization process using seismic data, so the main idea of this technique and a list of the author's researchers have been reviewed. In this review article, the reference approach using core analysis by distillation-extraction and retorting techniques have been explained, as well as the saturation-height method, which is based on the capillary pressure concept and wettability. Finally, alternative experimental approaches based on scanning are expressed in this manner.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with 4-(2-pyridylazo) Resorcinol-Application to Waters and Veterinary Preparation
...Show More Authors

This paper describes the development of a simple spectrophotometric determination of bismuth III with 4-(2-pyridylazo) resorcinol (PAR) in aqueous solution in the presence of cetypyridinium chloride surfactant at pH 5 which exhibits maximum absorption at 532 nm. Beer's law is obeyed over the range 5-200 µg/25 mL. i.e. 0.2-8 ppm with a molar absorptivity of 3×104 l.mol-1.cm-1 and Sandell's sensitivity index of 0.0069 µg.cm-2. The method has been applied successfully in the determination of Bi (III) in waters and veterinary preparation.

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Determination of Antibodies (IgG, IgM) against Toxoplasma gondii in Some Iraqi individuals by using ELISA technique
...Show More Authors

A total of 258 voluntary blood donors (males 101; females 157) in the age range of 18-52 yr among males and 18-55 yr among females were examined for Toxoplasma gondii antibodies (IgG), and (IgM) by immunological technique (Enzyme linked Immunosorbant Assay) during the period from March 2009 to April 2010. This study covered a wide range of factors including immunological, age ,sex , place of residence and symptoms that may have a possible relationship with toxoplasmosis. Results presented in this study showed clearly that 38 (14.7%) of individuals participated in this study having IgG Toxoplasma Ab, among those 10 samples (9.9%) were males and 28 samples (17.8%) were females. Moreover, we found the prevalence of IgM seropositivity in th

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Dec 30 2016
Journal Name
International Journal Of Applied Chemistry
Spectrophotometric Determination of Co(II) by Using Ethyl Cyano(2-Methyl Carboxylate Phenyl Azo Acetate) (ECA)
...Show More Authors

A new simple and sensitive spectrophotometric method for the determination of trace amount of Co(II) in the ethanol absolute solution have been developed. The method is based on the reaction of Co(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in acid medium of hydrochloric acid (0.1 M) givining maximum absorbance at ((λmax = 656 nm). Beer's law is obeyed over the concentration range (5-60) (μg / ml) with molar absorptivity of (1.5263 × 103 L mol-1 cm-1) and correlation coefficient (0.9995). The precision (RSD% ˂ 1%). The stoichiometry of complex was confirmed by Job's method which indicated the ratio of metal to reagent is (2:1). The studied effect of interference elements Zn(II), Cu(II), Na(I), K(I), Ca(II) and Mg

... Show More
Preview PDF
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Quantitative Determination and Cytotoxic Effect of Oleanolic Acid from Olea europaea Leaves Extract Cultivated in Iraq
...Show More Authors

Since its first description as a cytotoxic agent, Olea europaea leaves extract gained significant popularity against human breast cancer, ethyl acetate extract of Olea europaea leaves obtained by acid hydrolysis method was evaluated in vitro as cytotoxic agent against new human breast cancer (AMJ13) cell line, using the MTT assay. One main pentacyclic triterpenoid; oleanolic acid, was isolated from leaves of Olea europaea by well-known two different methods, but not used for this compound before, the acidic hydrolysis method and basic acidic method. The presence of oleanolic acid was proved in both methods with qualitative and quantitative d

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Study Analytical of The Effect Magnesium ion Concentration to Determination the Total Hardness And Comparison Spectrophotometry
...Show More Authors

The determination hardness in water raised to rivers caused several problem in the validity of the water used depends on where determination ions concentration calcium and magnesium in salts carbonate and sulfate , this possibility of separation between of these ions and the resulting impact on concentration and determination the degree of hardness water and appreciation between the insolvent water quality . It study the effect of the impact of concentration magnesium ion in determination the quality of the water has turned out to be Mg concentration more than 60% of the total content of hardness is borderline in hardness effect the determination. Adopted in this research determination the ions in two method titration by EDTA solution and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Finite Difference Methods,theory And Applications
Determination of the Time-Dependent Thermal Conductivity in the Heat Equation with Spacewise Dependent Heat Capacity
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
DETERMINATION OF ADVANCED OXIDATIVE PROTEIN PRODUCTS LEVELS AND ITS CORRELATION WITH INFLAMMATION IN DIABETIC FOOT PATIENTS
...Show More Authors

protein oxidation through oxidative stress, which represents the overall status of the protein in the cell/tissue. Due to their increased levels of AOPPs were reported during T2DM. The aim of this study was to assess AOPP level in T2DM subjects with foot ulcer (DFU) and explore its correlation with infection. Type 2 diabetic patients (n=108) and healthy subjects (n=25) were enrolled in this study. The T2DM group was subdivided to diabetic patients without complications (n=25) and eighty-three (83) of them have diabetic foot. They were sub- grouped into two groups according to presence Osteomyelitis and abscess, and in reliance on medical analysis of WBC count and CRP. Group of diabetic without superficial or deep ulcer and no osteomyelitis

... Show More
Scopus (3)
Scopus
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Phenylephrine hydrochloride and Salbutamol sulphate drugs in pharmaceutical preparations using diazotized Metoclopramide hydrochloride
...Show More Authors

A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and l

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Aug 02 2010
Journal Name
Ibn Al-haitham J.for Pure &appl.sci
The Spectrophotometric Determination of Samarium (III) With (l-2(2-Benzoinidazoly-AZO)-2-Hydroxy-3Naphthoic Acid
...Show More Authors

Samarium(III) ions react with (l-2(2-benzoinidazolyl-azo)-2-hydroxy-3-naphthoic acid in basic medium (pH = 8.0) forms a red-orange complex at A.max (550nm). The complex was found to be stable for at least 48 hrs. at the given pH. The apparent molar absorptivity is 7776.77 L.mol-1.Cm-1 and a linear calibration curve is obtained in the range (0.639x 10-5M - 6.350x 10 -5M). The stoichiometry of complex was confirmed by using mole ratio method which indicated that ratio of reagent to metal is 3:1. The effects of the presence of different cations and anions as interferences in the determination of samarium(III) under the given conditions were investigated