A precise evaluation of caries excavation endpoint is essential in clinical and laboratory investigations. Caries invasion differentiates dentin into structurally altered layers. This study assessed these changes using Raman spectroscopy and Vickers microhardness. Ten permanent molars with occlusal and proximal carious lesions were assessed and compared at 130 points utilizing four Raman spectroscopic peaks: phosphate v1 at 960 cm−1, amide I (1650 cm−1), amide III (1235 cm−1) and the C-H bond of the pyrrolidine ring (1450 cm−1). The phosphate-to-amide I peak ratio and collagen integrity peak ratio (amide III: C-H bond) of carious zones were calculated and compared in both lesions. The former ratio was correlated to 130 Vickers microhardness indentations through lesions. The caries-infected dentin (CID) exhibited low phosphate peak, but higher amide I, III and C-H bond peaks than other zones in both lesions. The peaks in amide regions (I and III) varied in occlusal versus proximal lesions. A high correlation was found between mineral: matrix peak ratio and equivalent microhardness number within carious lesions, while the collagen integrity peak ratio was applied in proximal lesions only. Raman spectroscopy detected changes in the mineral and matrix contents within different carious zones and regions.
Objectives: to assess chronic diseases patients’ knowledge toward stroke risk factors and warning signs, besides
determining the relationship between chronic diseases patients’ knowledge and their sociodemographical
characteristics.
Methodology: A descriptive study was carried out at public medical clinics which has started from December
2
nd, 2008 to August 8th, 2009. A purposive "non-probability" sample of (300) chronic diseases individuals who
were clients of Public Medical Clinics who have one or more of the following chronic diseases (hypertension,
diabetes mellitus, heart diseases, and previous stroke), in Baghdad city. The data were collected through the use
of a constructed questionnaire which consists
The Back-Propagation (BP) is the best known and widely used learning algorithm in training multiple neural network. A vast variety of improvements to BP algorithm have been proposed since ninety’s. in this paper, the effects of changing the number of hidden neurons and activation equation are investigated. According to the simulation results, the convergence speed have been improved and become much faster by the previous two modifications on the BP algorithm.
This investigation was carried out to estimate the antiparasitic potential of chitosan nanoparticles loaded with paromomycin against
This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.
Background: Oral squamous cell carcinoma (OSCC) is a common malignancy characterized by poor prognosis and low survival rate. The purpose of this study was to evaluate the Immunohistochemical expressions of BAD, MDM2, and P21as apoptotic markers in oral squamous cell carcinoma. Materials and methods: This study was performed on forty formalin-fixed paraffin-embedded blocks which histopathologically diagnosed as Oral Squamous Cell Carcinoma. All cases were collected from the Histopathological Laboratory from patients treated surgically at Maxillofacial surgery Department at Ramadi Teaching Hospital, Iraq. Results: The immunohistochemical staining of BAD showed positive expression in 39 (97.5%), MDM2 showed positive expression in 39(97.5%)
... Show MoreBackground: Mobile phones are approximately widely used everywhere like in hospital wards, clinics and universities as well as biomedical laboratories. They have become very important tool in students’ life. In contrast, these tools carry many harmful bacteria which are responsible for infectious diseases in human because they serve as a reservoir for different pathogens. Current study was aimed to isolate bacteria from students’ mobile phones at the Institute of Medical Technology/Al-Mansour/The Middle Technical University, Baghdad, Iraq. Also, the study investigated microbial resistance to many antimicrobial agents as well as the appropriate remedial measures. Method: Four hundred and fifty swabs from mobile phones were collected from
... Show MoreFlow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by
... Show MoreA simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations
... Show More