Preferred Language
Articles
/
4RezopEBVTCNdQwCQpbu
Photobleaching Influence in Different Phases for Coumarin 307 and Acriflavine Laser Dyes
...Show More Authors

Abstract: Under high-excitation irradiance conditions to induce fluorescence, the dependence of photobleaching of Coumarin 307 (C307) and acriflavine (ACF) laser dyes in liquid and solid phases have been studied. A cw LD laser source of 1 mW and 407 nm wavelength was used as an exciting source. For one hour exposure time, it was found that the solid dye samples suffer photobleaching more than the liquid dye samples. This is because in liquid solutions the dye molecules can circulate during the irradiation, while the photobleaching is a serious problem when the dye is incorporated into solid matrix and cannot circulate.

Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 23 2020
Journal Name
Iraqi Journal Of Laser
Effect of High Energy Nd:Glass Laser on the Drilled in the 5052 AlMg Alloy
...Show More Authors

This study presents the effect of laser energy on burning loss of magnesium from the holes' drilled in aluminum alloy 5052. High energy free running pulsed Nd:Glass laser of 300 µs pulse duration has been used to perform the experiments. The laser energy was varied from 1.0 to 8.0 Joules, The drilling processes have been carried out under atmospheric pressure and vacuum inside a specially designed chamber. Microhardness of the blind drilled holes has been investigated .The results indicated that the magnesium loss could be manipulated by adjusting the focusing conditions of the laser beam. Almost, the obtained holes were free of cracks with low taper and low sputter deposition. .The holes performed under atmospheric conditions have high

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
The performance of a passively Q-switched Cr:YAG4+ in an end- pumped laser system
...Show More Authors

A characteristic study of a passively Q-switched diode pumped solid state laser system is presented in this work. For laser a comparison study for the theoretically calculated results with a simulation results using a software which calculates the Q-switched solid state laser parameters was such as energy, peak power and pulse width were performed. There was a good agreement between our theoretical calculations and the simulation values.

View Publication Preview PDF
Publication Date
Sat Jun 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of ER: YAG laser on apical microleakage (in vitro study)
...Show More Authors

Background: Apicoectomy and retrograde filling is indicated when conventional endodontic treatment is impossible or failed to achieve apical seal. The aim of this study was to evaluate the effect of ER: YAG laser on apical microleakage. Materials and Methods: Sixty extracted single-rooted teeth were used in this study. The roots were divided into six groups. Group 1: apicoectomy by fissure bur, and apical cavities prepared by round bur, then cavities were filled with MTA. Group 2: the roots preparations and fillings were the same as group 1, then the apical areas were treated by Er:YAG Laser. Group 3: apicoectomy by fissure bur, and apical cavities prepared by ultrasound retrotip and cavities were filled with MTA. Group 4: the roots prepara

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
One dimensional Finite Element Solution of Moving Boundaries in Far IR Laser Tissue Ablation
...Show More Authors

In this work, the finite element analysis of moving coordinates has been used to study the thermal behavior of the tissue subjected to both continuous wave and pulsed CO2 laser. The results are compared with previously published data, and a good agreement has been found, which verifies the implemented theory. Some conclusions are obtained; As pulse width decreases, or repetition rate increases, or fluence increases then the char depth is decreased which can be explained by an increase in induced energy or its rate, which increases the ablation rate, leading to a decrease in char depth. Thus: An increase in the fluence or decreasing pulse width or increasing repetition rate will increase ablation rate, which will increase the depth of cut

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Survey of some Fish Species from Different Localities in Baghdad
...Show More Authors
Abstract<p>This study is concerned with a survey of seven species belonging to seven genera under two families and two orders found in some different areas of the Tigris River, especially since these areas have not been surveyed for a long time, and an attempt to identify the existing species at the present time after the recent water scarcity of the Tigris and Euphrates rivers and all water bodies interior of Iraq and the impact of this scarcity on the fish diversity found in some areas of the Tigris River in Baghdad.</p>
View Publication
Scopus Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Corrosion Behavior of Ti-6Al-4V Alloy in Different Media
...Show More Authors

     In this work the corrosion behavior of Ti-6Al-4V alloy was studied by using galvanostatic measurements at room temperature in different media which includ sodium chloride (food salt), sodium tartrate (presence in jellies, margarine, and sausage casings,etc.), sodium oxalate (presence in fruits, vegetables,etc.), acetic acid (presence in vinegar), phosphoric acid (presence in drink), sodium carbonate (presence in 7up drink,etc.), and sodium hydroxide in order to compare.

     Corrosion parameters were interpreted in th

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Color Stability of Different Aesthetic Archwires (An In vitro study)
...Show More Authors

Background: Coated aesthetic archwires are currently the existing solutions for the esthetic problem, but the color of these archwires tends to change overtime. This study was aimed to evaluate the color stability of different types of esthetic archwires from four different companies at different time periods after immersion of two different staining drinks which are tea and Pepsi cola. Materials and methods: 48 specimens were prepared, each specimen contains 10 aesthetic archwires; and were divided according to type of solution into two groups: A (tea) &B (Pepsi cola); each group contained 24 specimens (12 specimens were immersed in the staining solution as 4 specimens for each time intervals and 12 specimens were immersed in distilled wa

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jul 10 2017
Journal Name
Asian Journal Of Pharmaceutical Research And Health Care
Health Literacy among Women with Different Educational States in Baghdad
...Show More Authors

Health literacy is an important method used by the authorities to strengthen the health system. The aim of this study is to assess the knowledge of some basic health principles among women of different educational states. This is a crosssectional study, performed from December 2014 until January 2016, Baghdad. All candidates were: females &gt; 18 years, neither medical staff nor students. They were divided into two groups: educated and uneducated. The sample included 213 women, there were 112 educated and 101 uneducated women. Regarding educated group, accurate answers regarding route of transmission of typhoid fever was 73.2% in educated subjects vs. 49.5% in uneducated subjects. Main source of information for both groups was p

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sat Jun 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Ions release from fixed orthodontic appliance in two different mouthwashes
...Show More Authors

Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity; prophylactic mouthwashes may have an effect on ion release from orthodontic wires. Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS and NiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care (fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorption spectrophotometer and compared statistically. Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higher for Silver Care group than for Claradone group.

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 01 2016
Journal Name
Nurse Education Today
Diabetes knowledge of nurses in different countries: An integrative review
...Show More Authors

View Publication
Scopus (44)
Crossref (40)
Scopus Clarivate Crossref