Antibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, AlKindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18 column. A combination of methanol and deionized water made up the mobile phase system. For a 20-minute analysis period, the detector's excitation and emission wavelengths were set to 310 and 420 nm, respectively. Cleaning the SPE cartridge came after the extraction using pH 4 citrate buffer. Excellent linear ties (R2 > 0.9998) were seen in the calibration curves for levofloxacin and tetracycline at concentrations between 10 and 40 µg/ml. The limits of detection and quantification for levofloxacin and tetracycline were determined to be 0.61 µg/ml, 2.04 µg/ml, and 0.46 µg/ml and 1.54 µg/ml, respectively. The analysis of residues of antibiotics in various wastewater samples was successfully applied using the suggested methodology. The findings demonstrate the presence of tetracycline and levofloxacin in all wastewater samples. However, Al-Kindi had greater concentrations of them than Medical City and Al-Yarmouk. The proposed technique can be applied to a range of medical products in different wastewater sources, such as hospitals and industrial settings.
This study is conducted to determine the activity of plant Vica faba and two isolated from arbuscular mycorrhizae fungi (A,B) in bioremediation of soil pollution by Nickel and Lead elements in north and south of Baghdad city. The results showed that the average of soil pollution by Nickel and Lead elements in north of Baghdad was less than the average of soil pollution in the south of Baghdad which recorded 29.0,9.0PPm and 42.0, 25.0PPm respectively. The results show that the isolate A from the polluted soil is more active from isolate B which isolate from unpolluted soil for bioremediation. Vica faba recorded more in accumulate the Lead element in shoot system which was 19.65PPm and in root system was 27.2PPm and for Nickel element 24.65
... Show MoreA new Schiff base ligand [2,3,8,9–tetra -phenyl-1,4,5,7,10,12-hexa azo-5,12- dihydro -6,11- dione 1,3,7,10-dudec-tetra-ene] [H2L] and its complexes In general formula [M(H2L)]Cl2 (where : M= CoII, NiII, and PdII) were prepared. This ligand was prepared in two steps,in the first step a solution of benzil in methanol was reacted under reflux with semicarbazidhydrochlorid to give an (intermediate compound)[benzyl bis–(Semicarbazone)] which was reacted in the second step with benzil giving the mentioned ligand. The
... Show MoreIn this study, a 3 mm thickness 7075-T6 aluminium alloy sheet was used in the friction stir welding process. Using the design of experiment to reduce the number of experiments and to obtain the optimum friction stir welding parameters by utilizing Taguchi technique based on the ultimate tensile test results. Orthogonal array of L9 (33) was used based on three numbers of the parameters and three levels for each parameter, where shoulder-workpiece interference depth (0.20, 0.25, and 0.3) mm, pin geometry (cylindrical thread flat end, cylindrical thread with 3 flat round end, cylindrical thread round end), and thread pitch (0.8, 1, and 1.2) mm) this technique executed by Minitab 17 software. The results showed th
... Show MoreThis study was aimed to investigate the effect of sperm parameters on the response to in vitro sperm activation (ISA) and to compare sperm parameters according to the age and type of infertility.
One hundred twenty-eight subjects employed in this study, with age range (18-49) years and duration of infertility (1-28) years. From each subjects semen sample was obtained and seminal fluid analysis (SFA) was done. Simple medium for assisted reproductive techniques; (SMART) was used for in vitro sperm activation by direct swim-up technique and centrifugation Swim-Up technique. Sperm concentration, sperm motility (%), sperm grade activity (%), normal sperm morphology (%) and sperm agglutination (%) were assessed. Crude data were statisticall
The objective of this paper is to improve the general quality of infrared images by proposes an algorithm relying upon strategy for infrared images (IR) enhancement. This algorithm was based on two methods: adaptive histogram equalization (AHE) and Contrast Limited Adaptive Histogram Equalization (CLAHE). The contribution of this paper is on how well contrast enhancement improvement procedures proposed for infrared images, and to propose a strategy that may be most appropriate for consolidation into commercial infrared imaging applications.
The database for this paper consists of night vision infrared images were taken by Zenmuse camera (FLIR Systems, Inc) attached on MATRIC100 drone in Karbala city. The experimental tests showed sign
Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)
... Show More