irrigation use at many stations along the Euphrates River inside the Iraqi lands and to try to correlate the results with the satellite image analyses for the purpose of making a colored model for the Euphrates that can be used to predict the quality classifications of the river for irrigation use at any point along the river. The Bhargava method was used to calculate the water quality index for irrigation use at sixteen stations along the river from its entrance to the Iraqi land at Al-Qaim in Anbar governorate to its union with the Tigris River at Qurna in Basrah governorate. Coordinates of the sixteen stations of the Euphrates River were projected at the mosaic of Iraq satellite image which was taken from LANDSAT satellite for bands 1, 2 and 3. It was noticed that there was a strong negative correlation between the water quality index and the digital numbers at band 2 for the mosaic satellite image. A regression model was built between the water quality index at December, 2009 and the digital number at band 2 so as to build a colored model which was used to predict a water quality classification for irrigation use at any point along the river.
The research aims to identify how to enhance the quality of the human resources, focusing on four dimensions (efficiency, effectiveness, flexibility, and reliability), by adopting an adventure learning method that combines theoretical and applied aspects at the same time, when developing human resources and is applied using information technology, and that Through its dimensions, which are (cooperation, interaction, communication, and understanding), as the research problem indicated a clear deficiency in the cognitive perception of the mechanism of employing adventure learning dimensions in enhancing human resources quality, so the importance of research was to present treatments and proposals to reduce this problem. To achieve
... Show MoreThis work was conducted to study the extraction of eucalyptus oil from natural plants (Eucalyptus camaldulensis leaves) using water distillation method by Clevenger apparatus. The effects of main operating parameters were studied: time to reach equilibrium, temperature (70 to100°C), solvent to solid ratio (4:1 to 8:1 (v/w)), agitation speed (0 to 900 rpm), and particle size (0.5 to 2.5 cm) of the fresh leaves, to find the best processing conditions for achieving maximum oil yield. The results showed that the agitation speed of 900 rpm, temperature 100° C, with solvent to solid ratio 5:1 (v/w) of particle size 0.5 cm for 160 minute give the highest percentage of oil (46.25 wt.%). The extracted oil was examined by HPLC.
The aim of this investigation was to study the impact of various reaction parameters on wastewater taken from Al-Wathba water treatment plant on Tigris River in south of Baghdad, Iraq with sodium hypochlorite solution. The parameters studied were sodium hypochlorite dose, contact time, initial fecal coliform bacteria concentration, temperature, and pH. In a batch reactor, different concentrations of sodium hypochlorite solution were used to disinfect 1L of water. The amount of hypochlorite ions in disinfected water was measured using an Iodimetry test for different reaction times, whereas the Most Probable Number (MPN) test was used to determine the concentration of coliform bacteria. Total Plate Count (TPC) was utilized in this study to
... Show MoreThis research studies the influence of water source on the compressive strength of high strength concrete. Four types of water source were adopted in both mixing and curing process these are river, tap, well and drainage water (all from Iraq-Diyala governorate). Chemical analysis was carried out for all types of the used water including (pH, total dissolved solids (TDS), Turbidity, chloride, total suspended solid (TSS), and sulfates). Depending on the chemical analysis results, it was found that for all adopted sources the chemical compositions was within the ASTM C 1602/C 1602M-04 limits and can be satisfactorily used in concrete mixtures. Mixture of high strength concrete for compressive strength of (60 MPa) was designed and checked using
... Show MoreSeveral toxigenic cyanobacteria produce the cyanotoxin (microcystin). Being a health and environmental hazard, screening of water sources for the presence of microcystin is increasingly becoming a recommended environmental procedure in many countries of the world. This study was conducted to assess the ability of freshwater cyanobacterial species Westiellopsis prolifica to produce microcystins in Iraqi freshwaters via using molecular and immunological tools. The toxigenicity of W. prolifica was compared via laboratory experiments with other dominant bloom-forming cyanobacteria isolated from the Tigris River: Microcystis aeruginosa, Chroococcus turigidus, Nostoc carneum, and Lyngbya sp. signifi
... Show MoreThis study is conducted to verify the efficienecy of local Ninivite rock when used in the treatment of drinking water in plants operating currently in the country in order to develop the situation of these stations to cope with the increase in population. Also, this will limit the pollutian which are increasing in the country's rivers.
(Euphrates and Tigris). These rivers are the sources to feed all water treatment plants in the country. The idea is the develop or the modify these stations by replacing part of top layer of sand filters used in these stations with Ninivite rock to operate as filters composed of two medium. The efficiency of this rock is compared with other materials used successfully worldwide in this area, such a
... Show MoreThe aim of the present study is to study the meiobenthic invertebrate's community associated with the aquatic plant Ceratophyllum demersum in Al-Salamiyat irrigation canal / north Baghdad, with the chemical and physical parameters of the canal water, during the study period from September 2015 to May 2016. Two sites were chosen for sample collection, the first site (S1) at the beginning of the canal near it's connection with Tigris river, and the second site (S2) after 10 km from the first site. The chemico-physical analysis results revealed that the water temperature ranged from 10-30oC, and pH values ranged between 6.9-7.8, and the dissolved oxygen concentration and the BOD values from 7.2-9.2 mg/l, and 1.2-5.4 mg/l, respectively. The sal
... Show MoreIn this study, a total of 209 individuals of leeches were collected from Al-Hindyia River / Babil Province. 116 individuals were identified as Erpobdella octaculata (Linnaeus, 1758), 50 individuals as Erpobdella punctata (Leidy,1870) and 43 individuals as Hemiclepsis marginata (Müller, 1774). Four samples were collected monthly during a period from February to June 2018. Some physical and chemical water properties were also examined, including air and water temperature, potential of hydrogen pH, Electrical Conductivity EC, Total Dissolved Solid TDS, Dissolved Oxygen DO, and the Biological Oxygen Demand BOD₅. Air and water temperature were r
... Show MoreThis paper discusses the role of Auditors' Technological Maturity in reinforcing the quality of auditing profession, through focusing on the concepts of Technological Maturity and quality of auditing profession, as well as designing a proposed model for Technological Maturity which includes five evolutionary and sequential stages, and this proposed model would contribute to reinforce the quality of auditing. This proposed model will be employed in the field of auditing profession because the importance of the development and investment in this profession and the importance of the need for specialized knowledge in Information Technology, and the result of a proposed model is development of technological knowledge for the auditor to reach
... Show MoreIn this research, a selection of some mineral water was selected on the basis of being the most marketed by the owners of shops in Najaf province, with six types, where daily samples of this water were taken by 50 ml for two months from (1/11/2018 -1/1/2019). The following ions concentrations were measured (Br-, Cl-, F-, NO3-, SO42-, Na+, K+, Ca2+, Mg2+), pH and the electrical conductivity were measured and the results were compared with the allowable rates according to the international organizations. It was noted that they conform to international and Iraqi standards.