irrigation use at many stations along the Euphrates River inside the Iraqi lands and to try to correlate the results with the satellite image analyses for the purpose of making a colored model for the Euphrates that can be used to predict the quality classifications of the river for irrigation use at any point along the river. The Bhargava method was used to calculate the water quality index for irrigation use at sixteen stations along the river from its entrance to the Iraqi land at Al-Qaim in Anbar governorate to its union with the Tigris River at Qurna in Basrah governorate. Coordinates of the sixteen stations of the Euphrates River were projected at the mosaic of Iraq satellite image which was taken from LANDSAT satellite for bands 1, 2 and 3. It was noticed that there was a strong negative correlation between the water quality index and the digital numbers at band 2 for the mosaic satellite image. A regression model was built between the water quality index at December, 2009 and the digital number at band 2 so as to build a colored model which was used to predict a water quality classification for irrigation use at any point along the river.
A field study investigated the degree of need for managers working in the directories of education to develop their skills for the exercise of administrative empowerment, and it adopted the descriptive analytical approach. The research community, was determined which consisted of 126 principals, and the sample was selected with arte of randomly Statistics and by (100%) of the research community, as the number of respondents was (126) of managers working in the directories of education. A questionnaire was built which included 40 items distributed among the fields of study. Researchers verified its validity and reliability. The research data were analyzed using software (SPSS), the questionnaire was applied in the second semester of the a
... Show MoreTo use quality indicators to study the management of ST-segment elevation myocardial infarction (STEMI) in different regions.
Prospective cohort study of STEMI within 24 h of symptom onset (11 462 patients, 196 centres, 26 European Society of Cardiology members, and 3 affiliated countries). The median delay between arrival at a percutaneous cardiovascular intervention (PCI) centre and primary PCI was 40 min (interquartile range 20–74) with 65.8% receiving PCI
The goal of this research to identify the effect of the probing questions in the collection of material literature with students of the Kurdish language department, to achieve the aim of the research, the researcher has chosen a sample from the students of third stage of the Kurdish language Department, Faculty of Education / Ibn Rushd as a field for the application of experiment.The number of sample reached (71) students divided into two groups represented two divisions of the experimental groups under study to the style of questions sounding by (35) students, and represented the other division of the control group, which studied in the way normal and by (36) students, as rewarded r
... Show MoreQuality control of well logs has always been an important objective in reservoir studies because of the key role played by well logs as input data. This study aims to make a quality control on well logs data for two wells of Yamama formation in southern Iraqi field to ensuring and enhancing the measurement accuracy. In the beginning, the calibration data of before and after surveys are applied as initial evaluation for the quality of density log in well R-1. Then, depth matching is used to fit the depth of all logs in each well. After that, the comparison between the main and repeat sections is helped to check the repeatability. Finally, all uncorrected logs are environmentally corrected to remove the effects of the borehole conditi
... Show MoreA simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r
... Show MoreNatural polymers are often non-toxic, biodegradable, biocompatible, and safe. A novel ligand was synthesized as a natural polymer using chitosan and oleander plant extract [(2R,3S,4R,5S)-5-(acetoxyamino)-4-hydroxy-3,6-dimethoxytetrahydro-2H-pyran-2-yl) methyl (16R)-3-(((2S,4S,5R)-4-methoxy-2,5-dimethyltetrahydro-2H-pyran-2-yl)oxy-10,13,16-trimethyl-17-(5-oxo-2,5-dihydrofuran-3-yl) hexadecahydro-14H-cyclopenta [a] phenanthren-14-yl) phthalate] (Chitosan-Ph-Oleander). This ligand and its complexes with several metals (Cr+3, Mn+2, Fe+3, Ni+2, Cu+2, Zn+2) were characterized using FTIR, UV-visible and 1H-NMR spectroscopy, as well as by molar conductivity, magnetic moment, and TGA analysis. The biological activity for the prepared polymer
... Show MoreThis study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670
... Show MoreThin films of Magnetite have been deposited on Galvanized Steel (G-S) alloy using RF-reactive magnetron sputtering technique and protection efficiency of the corrosion of G-S. A Three-Electrodes Cell was used in saline water (3.5 % NaCl) solution at different temperatures (298, 308, 318 & 328K) using potentiostatic techniques with. Electrochemical Impedance Spectroscopy (EIS) and fitting impedance data via Frequency Response Analysis (FRA) were applied to G-S alloy with Fe3O4 and tested in 3.5 % NaCl solution at 298K.Results taken from Nyquist and Bode plots were analyzed using software provided with the instrument. The results obtained show that the rate of corrosion of G.S alloy increased with increasing the temperatures from 298 t
... Show MoreIn drilling fluid program, selecting the drilling fluid that will reduce the lost time is the first objective, and will be economical regardless of its cost. The amount and type of solids in drilling fluid is the primary control of the rheological and filtration properties. Palygorskite clay (attapulgite) is an active solid that has the ability to reactive with its environment and form a gel structure within a fluid and due to its stability in the presence of brines and electrolytes this type of clay is preferred for use. The aim of this study is to improve properties of Iraqi palygorskite (PAL) by adding different chemical additives such as caustic soda NaOH and soda ash Na2CO3 with a different con
... Show MoreThe objective of this study is to determine the concentration of copper and lead (mg/L) in drinking water by using absorption spectrophotometic and Atomic Absorption spectrophotometric method from different area in Baghdad and with different intervals , The results show that the concentration of copper and Lead ( mgL) in tap water which remains motionless in plumbing system for following periods one hours, 3 hours, 6 hours, 12 hours, 24 hours, 7 days and 14 days are (1 , 2.2 , 4 , 5.3 , 7.5 , 10 and 16 mgL copper ) & ( 0.3, 0.5 , 0.8 , 1 , 2.5 , 3 , 3.8 mg /L lead ) respectively .from these results its clear that high levels of copper & Lead occur if tap water comes in contact with copper - lead plumbing and copper lead -containing fix
... Show More