Background: Pemphigus vulgaris (PV) is an autoimmune vesiculobullous mucocutaneous disease with life-threatening consequences. Rituximab (RTX) has recently emerged as an effective treatment for PV. Objectives: This study aims to determine changes in neutrophil and platelet counts for PV patients treated with RTX or corticosteroids combined with Imuran (azathioprine). Materials and Methods: The present cross-sectional study was conducted in the Department of Dermatology at Baghdad Teaching Hospital, Baghdad, Iraq. Thirty PV patients received two types of treatment: 15 patients were administered RTX and 15 patients took corticosteroids with Imuran (azathioprine). Neutrophil and platelet counts were detected at the hospital laboratory. Results: The age range of PV patients was 27–67 years, and the mean ±SD was 44.866 ± 10.979 years for the patient group treated with RTX and 44.133 ± 11.519 for the patient group treated with corticosteroids and Imuran. In patients treated with RTX, 26.6% were males and 73.33% were females, with a female-to-male ratio of 2.75:1. In patients treated with corticosteroids with Imuran, 40% were males and 60% were females, with a female-to-male ratio of 1.5:1. The results revealed that among patients treated with RTX, 30% of them had mucocutaneous lesions, 6.66% had oral lesions, and 13.33% had cutaneous lesions. Among the other groups treated with corticosteroids and Imuran, 23.33% had mucocutaneous lesions, 13.33% had oral lesions, and 13.33% had cutaneous lesions. Among the patients treated with RTX, 53.33% had normal range of neutrophil count, while 46.6% had neutrophil count above the NR, while in patients treated with corticosteroids and Imuran, 40% had a normal range and 60% had above the normal range. Conclusion: RTX was a more effective treatment compared to corticosteroids with Imuran because no patient remained in an active state during this study. PV was prevalent in females aged 40 years with mucocutaneous lesions.
The current study was conducted to investigate Annona fruit pulp effects on the levels of various physiological biomarkers linked with insulin-dependent diabetes mellitus after disease induction in mice, as well as indications of oxidative stress and male hormones. The rats were separated into four groups, three of which were given Alloxan (90 mg/kg body weight) to induce diabetes, while the fourth served as a negative control. The first group of diabetic mice received no therapy, the second received metformin (600 mg/kg body weight) and the third received Annona fruit puree. The mice were sacrificed at the end of the experiment, to acquire blood and tissue samples from the liver, kidneys and spleen. The first untreated gro
... Show MoreBackground: Orthodontic therapy often causes external root resorption. Serum vitamin D (VD) level is important for tooth mineralization and bone remodeling. This study aimed to test the impact of vitamin D (VD) supplements on bone and root remodelling in a vitamin D (VD) deficient rat model following orthodontic retention. Methods and Material: 30 male Wistar rats were divided into three groups: a control group of 10 rats and two experimental groups of 10 rats each with vitamin D deficiency (VDD) induced by a VD-free diet for 21 days. And a third group with VD supplementAll groups received orthodontic active treatment using a modified orthodontic appliance that applied 50 gm of force for 14 days to move the maxillary right first mol
... Show MoreIn this paper, the impact of magnetic force, rotation, and nonlinear heat radiation on the peristaltic flow of a hybrid bio -nanofluids through a symmetric channel are investigated. Under the assumption of a low Reynolds number and a long wavelength, the exact solution of the expression for stream function, velocity, heat transfer coefficient, induced magnetic field, magnetic force, and temperature are obtained by using the Adomian decomposition method. The findings show that the magnetic force contours improve when the magnitude of the Hartmann number M is high and decreases when rotation increases. Lastly, the effects of essential parameters that appear in the problem are analyzed through a graph. Plotting all figures is done using the
... Show MoreIn this investigation, metal matrix composites (MMCs) were manufactured by using powder technology. Aluminum 6061 is reinforced with two different ceramics particles (SiC and B4C) with different volume fractions as (3, 6, 9 and 12 wt. %). The most important applications of particulate reinforcement of aluminum matrix are: Pistons, Connecting rods etc. The specimens were prepared by using aluminum powder with 150 µm in particle size and SiC, B4C powder with 200 µm in particle size. The chosen powders were mixed by using planetary mixing setup at 250 rpm for 4hr.with zinc stearate as an activator material in steel ball milling. After mixing process the powders were compacted by hydraulic
... Show More إن المقصود باختبارات حسن المطابقة هو التحقق من فرضية العدم القائمة على تطابق مشاهدات أية عينة تحت الدراسة لتوزيع احتمالي معين وترد مثل هكذا حالات في التطبيق العملي بكثرة وفي كافة المجالات وعلى الأخص بحوث علم الوراثة والبحوث الطبية والبحوث الحياتية ,عندما اقترح كلا من Shapiro والعالم Wilk عام 1965 اختبار حسن المطابقة الحدسي مع معالم القياس
(
Hetero junctions are fabricated by depositing antimony (Sb) and Al films on n-type single crystal(c-Si) wafers by the method of vacuum evaporation with thickness (0.25µm), with rate of deposition equals to 2.77 Å/sec, all samples are annealed in a vacuum for one hour at 473K. The tests have shown that all the films have polycrystalline structure for all Sb films. The barrier heights in (Sb/c-Si) junction was found to be equal 0.825eV, but(Al/c-Si) junction ohmic contact. Current-voltage measurements confirm this behaviour.
Under aerobic and anaerobic conditions, two laboratory-scale reactors were operated. Each reactor
was packed with 8.5 kg of shredded synthetic solid waste (less than 5 cm) that was prepared according to an
average composition of domestic solid waste in the city of Kirkuk. Using an air compressor, aerobic
conditions were created in the aerobic reactor. This study shows that the aerobic reactor was more efficient in
COD and BOD5 removal which were 97.88% and 91.25% while in case of anaerobic reactor, they were
66.53%and 19.11%, respectively.
Statistical methods of forecasting have applied with the intention of constructing a model to predict the number of the old aged people in retirement homes in Iraq. They were based on the monthly data of old aged people in Baghdad and the governorates except for the Kurdistan region from 2016 to 2019. Using Box-Jenkins methodology, the stationarity of the series was examined. The appropriate model order was determined, the parameters were estimated, the significance was tested, adequacy of the model was checked, and then the best model of prediction was used. The best model for forecasting according to criteria of (Normalized BIC, MAPE, RMSE) is ARIMA (0, 1, 2).
Statistical methods of forecasting have applied with the intention of constructing a model to predict the number of the old aged people in retirement homes in Iraq. They were based on the monthly data of old aged people in Baghdad and the governorates except for the Kurdistan region from 2016 to 2019. Using BoxJenkins methodology, the stationarity of the series was examined. The appropriate model order was determined, the parameters were estimated, the significance was tested, adequacy of the model was checked, and then the best model of prediction was used. The best model for forecasting according to criteria of (Normalized BIC, MAPE, RMSE) is ARIMA (0, 1, 2)
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.
Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in Eye Specialty Private Hospital, Baghdad, Iraq.
Type of the Study: a prospective non randomize intervention study.
Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter
... Show More