Preferred Language
Articles
/
4BZ7aIgBVTCNdQwChHbC
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been performed for the intervals of one week pre-operatively, one and six months postoperatively. The evaluation included history of symptoms according to scoring systems, investigations and clinical examination. Results: One month postoperatively and in both groups, there was significant DED (P < .01), although the incidence was lower in femtosecond SMILE group, overall severity score (0-4): 0.3 ± 0.3 (FS-SMILE) vs. 1.4 ± 0.9 (LASIK). One month postoperatively, CS was lower in FS- LASIK more than FS-SMILE eyes (2.3 ± 2.2 vs 3.6 ± 1.8, respectively, P < .01) and then return to not statistically significant sensitivities at six-month duration. DED was negatively correlated with CS (P < 0.01). Conclusions: The FS-LASIK surgery had a more pronounced effect on the CS and DED compared with FS-SMILE, with higher incidence of DED postrefractive surgery.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Experimental Study on Heat Transfer and Friction Factor Characteristics of Single Layer Graphene Based DI-water Nanofluid in a Circular Tube under Laminar Flow and Different Heat Fluxes as Boundary Conditions
...Show More Authors

An experimental study was performed to estimate the forced convection heat transfer performance and the pressure drop of a single layer graphene (GNPs) based DI-water nanofluid in a circular tube under a laminar flow and a uniform heat flux boundary conditions. The viscosity and thermal conductivity of nanofluid at weight concentrations of (0.1 to 1 wt%) were measured. The effects of the velocity of flow, heat flux and nanoparticle weight concentrations on the  enhancement of the heat transfer are examined. The Nusselt number of the GNPs nanofluid was enhanced as the heat flux and the velocity of flow rate  increased, and the maximum Nusselt number  ratio (Nu nanofluid/ Nu base fluid)   and thermal performance factor

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 25 2019
Journal Name
Al-academy
The Dialectic of the Living Body (the actor) and the Dead Body (the Sinography Item) in the Construction of the Staged Image of the Play: جاسم كاظم عبد - عماد هادي عباس
...Show More Authors

The current research deals with the dialectical relationship resulting from the conflict in the violent combination and construction of the living ( the actor)and the dead (the item) in the structure of the Sinography construction and the emergence of the theatrical play space , which can be summed up by the following question: what is the nature of the dialectical relationship between the living (the actor) and the dead( the item) in the Sinography creation, which limited the research in a central objective : to identify the controversy of the living (actor) and the dead (item) in the performance unit of the theatrical scene . The research, in its objective limits set forth in its methodological framework, analyzes this controversy in o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
New Approach for the On-Line Spectrophotometric Determination of Folic Acid in Pure and Pharmaceutical Preparation via Oxidation by Cerium(IV) Sulphate Using Ayah 3Sx3-3D-Solar Cell CFI Spectrophotometer Analyzer
...Show More Authors

A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100μl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5  mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 08 2023
Journal Name
Iraqi Journal Of Science
Determination of Atenolol in pharmaceutical formulations by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o ) using Ayah 4SW-3D-T180 -2N90 -Solar - CFI
...Show More Authors

A simple, rapid and sensitive method for the analysis of Atenolol in pure and pharmaceutical preparation as an alternative analytical procedure were developed by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o). The method is based upon the formation of white precipitate for the ion pair compound by phosphomolybidic acid with Atenolol in aqueous medium. The precipitate is measured via the attenuation of incident light and scattering of the incident light in two opposite direction namely +90o and -90o angle were measured. Chemical and physical parameters were investigated. The linearity of Atenolol is ranged from (0.1-11) mmol.L-1, with correlation coefficient r=0.993

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 31 2023
Journal Name
Journal Of Molecular Modeling
Ab initio study of structural, mechanical and electronic properties of 3d transitional metal carbide in cubic rocksalt (rs), zincblende (zb), and cesium chloride (cc) structures by using LDA and GGA Approximation
...Show More Authors

This study rigorously investigates three 3d transition metal carbide (TMC) structures via LDA and GGA approximations. It examines cohesive energy (Ecoh), Vickers hardness (Hv), mechanical stability, and electronic properties. Notably, most 3d TMCs exhibit higher cohesive energy than nitrides, and rs-TiC demonstrates a Vickers hardness of 25.66 GPa, outperforming its nitride counterpart. The study employs theoretical calculations to expedite research, revealing mechanical stability in CrC and MnC (GGA) and CrC (LDA in cc structure), while all 3d TMCs in rs and seven in zb structures show stability. Charge transfer and bonding analysis reveal enhanced covalency along the series, influenced by the interplay between p orbitals of carbon and d o

... Show More
Publication Date
Fri Oct 01 2010
Journal Name
Analytica Chimica Acta
A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry
...Show More Authors

The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B1 and fumonisin B2 by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C18 solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith® RP-18e column

... Show More
View Publication
Scopus (30)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Sat Feb 01 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 01 2014
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Activating Financial Performance Measures On The Basis Of Value And Its Reflection On Companies Performance Under The Governance: An Applied Study On A sample Of Companies Listed In the Iraqi Stock Exchange
...Show More Authors

Increased attention to corporate governance with the increasing need for investors and other parties in the Iraqi market for securities of the information credible and confidence and greater transparency in the disclosure as well as the systems of governance lead to raise the value of the company and that by reducing the cost of capital and reduce the cost of financing, as well as that there are indications modern measurement can be adopted by the Iraqi market for securities for the purpose of evaluating the performance of listed companies and then raise their value.

   The research problem is that there is no framework or structure of the legal and local rules for the application of corporate governance in Iraq obliges

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2012
Journal Name
Diyala Agricultural Sciences Journal (dasj)
(OLIGO-X) the effect of salinity of irrigation water and magnetisation and soaking Alalascorbek acid and extracted sea Your protected agriculture. DALIA in germination and growth of seedlings seeds of hybrid option
...Show More Authors

Publication Date
Sat Feb 01 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Plasma Treatment on Shear Bond Strength of High Impact Acrylic Resin Denture Base Lined with Two Types of Soft Lining Materials after Immersion in Distilled Water and Denture Cleanser
...Show More Authors

Background: In dentistry, dentist takes the advantages of soft lining materials due to the viscoelastic properties. The major problem is the adhesion of the soft liner with the denture base material. Materials and Methods: Heat cured of high impact acrylic resin specimens prepared with dimensions 75x13x13mm for shear bond strength test, soft lining material (Refit and Mollosil) with a 3-mm thickness and used to join each two acrylic blocks. Also four specimens with the same previous dimensions utilized for chemical and physical surface analysis. The specimens grouped as control (without plasma) and experiment (with oxygen plasma) treated high impact acrylic specimens. Results: Plasma treatment increased the shear bond strength for both Refi

... Show More
View Publication Preview PDF