Preferred Language
Articles
/
4BZ7aIgBVTCNdQwChHbC
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been performed for the intervals of one week pre-operatively, one and six months postoperatively. The evaluation included history of symptoms according to scoring systems, investigations and clinical examination. Results: One month postoperatively and in both groups, there was significant DED (P < .01), although the incidence was lower in femtosecond SMILE group, overall severity score (0-4): 0.3 ± 0.3 (FS-SMILE) vs. 1.4 ± 0.9 (LASIK). One month postoperatively, CS was lower in FS- LASIK more than FS-SMILE eyes (2.3 ± 2.2 vs 3.6 ± 1.8, respectively, P < .01) and then return to not statistically significant sensitivities at six-month duration. DED was negatively correlated with CS (P < 0.01). Conclusions: The FS-LASIK surgery had a more pronounced effect on the CS and DED compared with FS-SMILE, with higher incidence of DED postrefractive surgery.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 08 2023
Journal Name
Journal Of Wasit For Science And Medicine
Study on physical properties of nanostructured ZnO prepared by pulse laser deposition
...Show More Authors

Zinc Oxide thin film of 2 μm thickness has been grown on glass substrate by pulsed laser deposition technique at substrate temperature of 500 oC under the vacuum pressure of 8×10-2 mbar. The optical properties concerning the absorption, and transmission spectra were studied for the prepared thin film. From the transmission spectra, the optical gap and linear refractive index of the ZnO thin film was determined. The structure of the ZnO thin film was tested with X-Ray diffraction and it was formed to be a polycrystalline with many peaks.

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental and Numerical Analysis of Laser Surface Melting by Using Enthalpy Method
...Show More Authors
Abstract<p>In this study, experimental and numerical applied of heat distribution due to pulsed Nd: YAG laser surface melting. Experimental side was consists of laser parameters are, pulse duration1.3<italic>ms</italic>, wavelength 1064nm, laser energies 1.5, 2. 6 and 4.3 J, laser beam diameter is 0.6 mm and spot diameter 0.78 mm was applied a low carbon steel type St37 with a dimension 10, 10, 3 mm, length, width and thickness respectively. Numerical analysis side consist of a mathematical model and calculating a thermal cycle by using equation in the enthalpy method applied to determine the cooling rate in fusion zone. The simulation by using the enthalpy method, applied on conduction heat transfer </p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Thu Aug 17 2017
Journal Name
Engineering And Technology Journal
Effect of Laser Surface Melting on Chromium Carbide of 304 Stainless Steels
...Show More Authors

SKF Sami I. Jafar, Mohammad J. Kadhim, Engineering and Technology Journal, 2018 - Cited by 4

View Publication Preview PDF
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Spectroscopic and structural properties of Zinc-Phthalocyanine prepared by pulsed laser deposition
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Nov 29 2018
Journal Name
Journal Of Electronic Materials
Numerical Modeling of 193-nm Excimer Laser Ablation on CR-39 Polymer
...Show More Authors

View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Design and study for transmitter system of laser Nd-YAG (1.06 ?m)
...Show More Authors

In this research , design and study a (beam expander) for the Nd – YAG laser with (1.06 ?m) Wavelength has been studied at 5X zoom with narrow diversion in the room temperature. by using (ZEMAX) to study the system. Evaluate its performance via (ZEMAX) outputs, as bright Spot Diagram via (RMS), Ray Fan Plot, Geometric Encircled Energy and the value of Focal shift. Then study the effect of field of view on the outputs in the room temperature.

View Publication Preview PDF
Crossref
Publication Date
Thu Oct 14 2021
Journal Name
Iraqi Journal Of Physics
Investigation of nonlinear optical properties for laser dyes-doped polymer thin film
...Show More Authors

Solutions of dyes Rhodamine 6G (Rh6G) and Coumarin480(C480) were prepared at five concentrations (1x10-3, 5x10-4, 1x10-4, 5x10-5 and1x10-5) mol/l, the mixing was stirred to obtain on a homogenous solution, the(poly methyl-methacrylate) (PMMA) was solved by chloroform solvent with certain ratio, afterward (PMMA+Rh6G) and (PMMA+C480) thin films were prepared by casting method on glass block which has substrate with dimensions (7.5 x2.5)cm2, the prepared samples were left in dark place at room temperature for 24 hours to obtain uniform and homogenous thin films. UV-VIS absorption spectra, transmission spectra and fluorescence spectra were done to measure linear refractive index and linear absorption coefficient. The nonlinear optical proper

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Hyperpigmentation using Q-Switched (1064nm and 532nm) Nd:YAG Laser
...Show More Authors

Hyperpigmentation is the increase in the natural color of the skin. The purpose of this study is to evaluate the efficacy and safety of Q-Switched Nd:YAG (1064 & 532 nm) Laser in treatment of skin hyper pigmentation. This study was done in the research clinic of Institute of laser for postgraduate Studies/University of Baghdad from October 2008 to the end of January 2009. After clinical assessment of skin hyperpigmentation color, twenty six patients were divided according to their lesions. Eight Patients with freckles, seven patients with melasma, four patients with tattoo. Cases with tattoo, were subdivided into amateur tattoos two, professional tattoos one, and one traumatic tattoo. Four Patients with post inflammatory hyperpigment

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 20 2010
Journal Name
Indian Journal Of Science And Technology
Investigation on picosecond laser ablation of dental material using FIB/SEM techniques
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Spatial Response Uniformity of Silicon–Based CdS and PbS Heterojunction Laser Detectors
...Show More Authors

This paper demonstrates the spatial response uniformity (SRU) of two types of heterojunctions (CdS, PbS /Si) laser detectors. The spatial response nonuniformity of these heterojunctions is not significant and it is negligible in comparison with p+- n silicon photodiode. Experimental results show that the uniformity of CdS /Si is better than that of PbS /Si heterojunction

View Publication Preview PDF