Background: Acute radiodermatitis is a common side effect during and after radiotherapy course in breast cancer patients treated by radiotherapy. This study assess the frequency of acute radiodermatitis and record the predictive factors for acute radiodermatitis. Patients and Methods: A descriptive case series study conducted at Baghdad, Iraq from August 2020 to September 2021. 70 female scheduled for radiotherapy sessions enrolled in this study. sociodemographic data were recorded and Skin examination before radiotherapy and weekly till the end of the radiotherapy sessions was done to report the frequency, risk factors, clinical picture and grades of acute radiodermatitis based on The National Cancer Institute’s Common Terminology Criteria for Adverse Events (CTCAE 4). Results: Fifty four (77.1%) female developed acute radiodermatitis during their radiotherapy sessions: 38 (70.4%) was Grade I, 12 (22.2%) Grade II and 4 (7.4%) Grade III. Statistically significant more severe radiodermatitis Grade among conventional dose group (54.5%) compared to (23.3%) in hypofractionation group (P=0.043). Acute radiodermatitis rate and grade was statistically significant high in patient using bolus during radiotherapy than in those did not use it (P=0.048, P=0.017) respectively. The Grade of radiodermatitis was statistically significant more severe in breast conservative surgery patients (P=0.046). Skin type I & II patients were more liable to radidermatitis compared with those with skin type III & IV (P=0.035). No significant associations between radiodermatitis and different patients’ and tumor characteristics. Conclusion: we found that conventional dose, addition of bolus, breast conservative surgery and patients skin type I&II were all significant factors that enhance skin reaction. Keywords: Breast cancer, Radiotherapy, Radiodermatitis.
Colorectal cancer is the world's 3rd most frequent malignant neoplasm and the 4th most common cancer in Iraq. Leptin and Adiponectin are two major Adipocytokines produced by adipose cells that have opposite effects on the formation of colorectal tumors. Leptin induces tumor growth and metastasis, whereas Adiponectin inhibits it. 1,25-Dihydroxyvitamin D controls and limits cancer cell proliferation, differentiation, and survival. Vitamin C deficiency, on the other hand, has been regularly detected in cancer tissues and has potent anti-cancer properties. The purpose of this study was to look at the biochemical role of circulatory Adipocytokine levels (Adiponectin and Leptin) as well as the anti-cancer potentials of Vi
... Show MoreThe study aims detection teaching modalities adopted relationship in Jerash University exactly the classroom, and to achieve the goal of the study was to develop a questionnaire consisting of (39) items, and was achieving validity and reliability have, then sent to a sample of professors made up the university from (122) university professor of the total (172) professor, and they study population.
Study found a relationship between the teaching methods of the four their strategies with classroom management, and as a result the overall average level, while Hspt critical thinking at the highest correlation with classroom discipline management relationship strategy, while the relatio
... Show MoreBACKGROUND: Genetic skeletal abnormalities are a heterogeneous group of genetic disorders frequently presenting with disproportionate short stature. AIM OF THE STUDY: To give an idea about the frequency of genetic skeletal abnormalities, and to find out whether these disorders are really increasing in the last 16 years or not. METHODS: During the period extending from (Jan, 1st 2003-April, 1st 2007), all cases of genetic skeletal disorders referred to the Genetic Counseling Clinic, Medical City – Baghdad who were born after 1991 were included in this study as the post-war group; the pre-war group, included all cases of skeletal disorders referred prior to 1991 (Jan., 1st 1987-Jan., 1st 1990). The demographic parameters, family history of
... Show MoreA simple physical technique was used in this study to create stable and cost-effective copper oxide (CuO) nanoparticles from pure copper metal using the pulsed laser ablation technique. The synthesis of crystalline CuO nanoparticles was confirmed by various analytical techniques such as particle concentration measurement using atomic absorption spectrometry (AAS), field emission scanning electron microscopy (FE-SEM), the energy dispersive X-ray (EDX), and X-ray diffraction (XRD) to determine the crystal size and identify of the crystal structure of the prepared particles. The main characteristic diffraction peaks of the three samples were consistent. The corresponding 2θ is also consistent, and the cytotoxicity of the nanoparticles was
... Show MoreThe present study aimed to identify the exact location and its relation to cognitive
method (risk_caution) to university students. The sample consisted of (300) students who
were chosen randomly and equally. The study results indicated that students possess an
internal exact location and they also use risk cognitive method. The study also indicated that
there is a prophesies which is an exact location for others to reach to caution cognitive
method. Depending on these results, the study recommended to benefit from the results of the
study variables and from the measurement of the exact location and method of cognitive
(risk_caution) to identify male and female students and especially by consulting units at
college
Gestational diabetes mellitus is glucose intolerance of varying degree with onset or first detection duringpregnancy,it can causelong and short term morbidities in both the mother and the child, such as shoulder dystocia,preeclampsia, and high blood pressure. The most powerful endogenous vasoconstrictor peptide, urotensin II, andits receptor are involved in the etiology of gestational diabetes mellitus.Aim of the study: The study’s goal was to see if there is a link between Urotensin II levels and insulin resistancein pregnant women with gestational diabetes.Patients and method: A case-control study that was conducted in obstetrics and gynecology department atBaghdad Teaching hospital from the first of January 2019 to the end of D
... Show MoreThe problem of frequency estimation of a single sinusoid observed in colored noise is addressed. Our estimator is based on the operation of the sinusoidal digital phase-locked loop (SDPLL) which carries the frequency information in its phase error after the noisy sinusoid has been acquired by the SDPLL. We show by computer simulations that this frequency estimator beats the Cramer-Rao bound (CRB) on the frequency error variance for moderate and high SNRs when the colored noise has a general low-pass filtered (LPF) characteristic, thereby outperforming, in terms of frequency error variance, several existing techniques some of which are, in addition, computationally demanding. Moreover, the present approach generalizes on existing work tha
... Show MoreAnti-Neutrophil Cytoplasmic Antibodies (ANCA) are a heterogeneous group of autoantibodies with a broad spectrum of clinically associated diseases. The diagnostic value is established for Proteinase 3 (PR3)-ANCA as well as Myeloperoxidase (MPO)-ANCA. To estimate the frequency of anti-neutrophile cytoplasmic antibodies (ANCA) in sera from a group of Iraqi patients with some autoimmune diseases compared with a healthy control group. Serum samples were collected from one hundred patient, 47 males and 53 females; with age range of 16-70 years; 20 specimens from patients with systemic lupus erythematosus (SLE), 30 from patients with ulcerative colitis (UC), and 50 from patients with rheumatoid arthritis (RA). A group of 40 apparently healthy b
... Show MoreThis research describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc
The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar & reference divider in single chip. Therefore our system consists of a single chip contains (low phase noise PFD, charge pump, prescalar & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip
... Show More