Background: Tap waters play an important role in fulfilling the people needs for drinking and domestic purposes. Contaminate the tap water with different pollutants has become an issue of great concern for 90% of people who are depended on the tap water as the main source of drinking. Pollutants can make their way easily into the delivering pipes which suffer from the leaking resulting in decreasing the quality of water. Objective: Therefore, assess the water quality for drinking purpose by calculating the water quality index is an important tool to ascertain whether the water is suitable for human consumption or not. Methods: In the present work, the water quality of the Al-Salam, western region of Baghdad city, Iraq was investigated for 7 months (Jan-July 2017). 63 tap water and 7 water station samples were collected and analyzed using standard methods. The index proposed measuring nine parameters which are: TDSs, pH, TH, DO, phosphates, nitrates, temp, BOD5, fecal coliform, turbidity and conductivity. The calculated values of parameters were normalized into the scale (0-100) and converted to the quality rating statements (Excellent, good, medium, bad and very bad). Results: The results show that WQI values of the tap water samples have ranged from 64- 83% while it ranged from 88-94 for the water station samples. Also, it can notice that none of the water samples is recorded WQI=100 during the entire period of the study. The proposed NFS index was able to determine the water quality and it presents an accurate, rapid and modern way to evaluate and monitor the water quality.
This study was carried out to determine the effects of some environmental variables on biodiversity index value of benthic invertebrates' community in samples that collected monthly from two adjacent sites nearby the confluence of Tigris and Diyala rivers within Baghdad city that’s from November 2007 - October 2008. Results showed differences in chemical and physical characteristics for each river. Where the annual averages of these characteristics in Rivers Tigris and Diyala respectively for: water temperature (20, 19) Cº, pH (8, 8), Dissolved oxygen DO(8,4 ) mg/l , EC(1152,2979)µc/cm , Turbidity (28,74) NTU, Total Hardness of CaCO3 (485,823)mg/l, and finally NO3 (4,6)mg/l. Concerning the biological groups, included types of Insect
... Show MoreClimate change in recent years has greatly affected the distribution of ground covers. Monitoring these changes has become very easy due to the development of remote sensitivity science and the use of satellites to monitor these changes. The aim of this research is to monitor changes in the spectral reflectivity of the Baghdad governorate center for the month (March, June, September, December) of the year 2021 using remote sensing and satellite images Sentinel 2 and knowing the climate imact on them. Fifty-one samples were selected for four types of ground cover (agricultural land, water, buildings and open space) and their spectral reflectivity was calculated using satellite images.
Formation of emulsions during oil production is a costly problem, and decreased water content in emulsions leads to increases productivity and reduces the potential for pipeline corrosion and equipment used. The chemical demulsification process of crude oil emulsions is one of the methods used for reducing water content. The demulsifier presence causes the film layer between water droplets and the crude oil emulsion that to become unstable, leading to the accelerated of water coalescence. This research was performed to study the performance of a chemical demulsifier Chimec2439 (commercial) a blend of non-ionic oil-soluble surfactants. The crude oils used in these experiments were Basrah and Kirkuk Iraqi crude oil. These
... Show MoreGhar Formation outcrop at the Iraqi western desert was studied by microfacies analysis
of (13) thin sections collected from wadi Al-Ratgha ( west of Qaim ) . According to
petrographic com position and organisms content ,rocks were subdivided into (4)
microfacies units :bioclastic wackestone , mudstone , miliolids wackestone , and grainstone
with aggregate grains microfacies .Microfacies units reflect shallow marine environment of
low circulation of very warm water at the middle part . The lower and middle part
interbedded with quite open marine environment below the wave base . The upper part was
deposited at shallow marine environment of low circulation . The main diagenetic processes
were the transformation ( ty
This study examines patterns of exposure of Iraqi university students to selective daily Iraqi newspapers and the motives of this exposure, as well as its associated factors that affect the average exposure. It tries to answer several questions, including those related to the levels of exposure of Iraqi university students to daily Iraqi newspapers and classification of patterns of selective exposure to daily Iraqi newspapers and the most prominent Iraqi daily newspapers that are selectively exposed by Iraqi university students. It also examines the motives of this selective exposure and factors that increase the degree of exposure to the daily Iraqi newspapers, and the most prominent stages in which Iraqi university students find their
... Show MoreThat water is the lifeblood and without it no life on our planet, he says in the Holy Koran: In the Name of God {{And We made from water every living thing}} truth of God Almighty (the prophets verse 30) The basis of the existence of settlements served human and a source of fresh water close to it easy access to it is used for domestic, agricultural, on a daily basis, even closer look at the map of Iraq to human settlement to find it is a signatory to both sides of the river are thick and less as we moved away from the source of water until they make up a scene like a necklace the river and the stones of cities and settlements served, was the ancient civilizations, countries and capitals Throughout history, choose sites near sour
... Show MoreThe fall angle of sun rays on the surface of a photovoltaic PV panel and its temperature is negatively affecting the panel electrical energy produced and efficiency. The fall angle problem was commonly solved by using a dual-axis solar tracker that continually maintains the panel orthogonally positioning to the sun rays all day long. This leads to maximum absorption for solar radiation necessary to produce maximum amount of energy and maintain high level of electrical efficiency. To solve the PV panel temperature problem, a Water-Flow Double Glazing WFDG technique has been introduced as a new cooling tool to reduce the panel temperature. In this paper, an integration design of the water glazing system with a dual-axis tracker has been ac
... Show MoreThis study was carried out in Baghdad (Al-Jadiriya) in 2006 by detecting ability of aquatic reed plant to remove heavy metals (Chromium) from waste water by batch process of adsorption with considering that acidic solution is best selection for such process with constant initial chromium concentration(60 mg/l),speed of shaking(300 rpm), temperature (30 Co) and constant contact time (4 h) but with different weights of adsorbent (reed) (0.5 ,1 ,2 ,3 and 4 )gm for each 100 ml volume of sample . The results showed that the percentage of the removed chromium were ( 8% ,17.5% ,31% ,40% and 50%) respectively for each sample according to the mass of adsorb
... Show MoreThe aim of this study was to investigate antibiotic amoxicillin removal from synthetic pharmaceutical wastewater. Titanium dioxide (TiO2) was used in photocatalysis treatment method under natural solar irradiation in a tubular reactor. The photocatalytic removal efficiency was evaluated by the reduction in amoxicillin concentration. The effects of antibiotics concentration, TiO2 dose, irradiation time and the effect of pH were studied. The optimum conditions were found to be irradiation time 5 hr, catalyst dosage 0.6 g/L, flow rate 1 L/min and pH 5. The photocatalytic treatment was able to destruct the amoxicillin in 5 hr and induced an amoxicillin reduction of about 10% with 141.8 kJ/L accumulate
... Show MoreFurfural is one of the one of pollutants in refinery industrial wastewaters. In this study advanced oxidation process using UV/H2O2 was investigated for furfural degradation in synthetic wastewater. The results from the experimental work showed that the degradation of furfural decreases as its concentration increases, reaching 100% at 50mg/l furfural concentration and increasing the concentration of H2O2 from 250 to 500 mg/l increased furfural removal from 40 to 60%.The degradation of furfural reached 100% after 90 min exposure time using two UV lamps, where it reached 60% using one lamp after 240 min exposure time. The rate of furfural degradation k increased at the pH and initial concentratio
... Show More