Background: Cardiovascular disease (CVD) is the number one cause of death worldwide. Objective: To determine of coronary care unit nurses' knowledge regarding patient rehabilitation after myocardial infarction. Methodology: A cross- sectional study was designed in the Cardiac Care Unit of Al-Diwaniyah Teaching Hospital and the Specialized Center for Cardiac Surgery and Catheterization for the period from (November 7, 2022) to (May 12, 2023). A non-probability (purposive) sample consisting of (75 nurses) working in the above-mentioned study site. To determination of coronary care unit Nurses' knowledge regarding patient rehabilitation after myocardial infarction, the researcher used a tool that consists of two parts: The first part: is the demographic data of the study sample, and the second part: nurses' knowledge about patient rehabilitation after myocardial infarction includes 28 items. Results: The study showed that (48%) of the nurses in the study sample had fair levels of knowledge regarding patient rehabilitation after myocardial infarction. It also showed that there is a statistically significant relationship between the nurses' knowledge and their age. Conclusion: The current study concluded that the largest percentage of the participants in the study have fair knowledge about patient rehabilitation after myocardial infarction, while a small number of them have satisfactory knowledge.
In this study, gamma ray transmission method have been used to determine the total porosity in four samples: pure Alumina ( Al2O3 ), Al2O3 + (0.2wt%)MgO , Al2O3 + (0.6wt% )Y2O3 and Al2O3+ (8wt% ) ZrO2 .
The experimental setup for the gamma ray transmission consist of 137Cs gamma source ( 662 KeV ), a NaI (Tl) scintillation detector measured the attenuation of strongly collimated gamma beam through alumina samples.
The porosity obtained by the gamma ray transmission method were compare
... Show MoreA new, simple and sensitive spectrophotometric method was described for the determination of famotidine (FAM) as a pure material and in pharmaceutical formulation. This method was based on diazotization and coupling reaction between famotidine and diazotized solution of metochlopramide hydrochloride (DMPH) in the presence of phosphate buffer solution to give a compound of azo dye having orange color soluble in water with high absorptivity at a wave length of 478 nm. The data shows that FAM and DMPH combine in the molar ratio of 1:1 at PH 7.0 .The method obeys Beer's law over concentration range of 1-40 ?g.ml-1 of famotidine with a correlation coefficient of 0.9955 and a detection limit of 0.10 ?g.ml-1. The apparent molar absorptivity re
... Show MoreMetal contents in vegetables are interesting because of issues related to food safety and potential health risks. The availability of these metals in the human body may perform many biochemical functions and some of them linked with various diseases at high levels. The current study aimed to evaluate the concentration of various metals in common local consumed vegetables using ICP-MS. The concentrations of metals in vegetables of tarragon, Bay laurel, dill, Syrian mesquite, vine leaves, thymes, arugula, basil, common purslane and parsley of this study were found to be in the range of, 76-778 for Al, 10-333 for B, 4-119 for Ba, 2812-24645 for Ca, 0.1-0.32 for Co, 201-464 for Fe, 3661-46400 for K, 0.31–1.
... Show MoreFor modeling a photovoltaic module, it is necessary to calculate the basic parameters which control the current-voltage characteristic curves, that is not provided by the manufacturer. Generally, for mono crystalline silicon module, the shunt resistance is generally high, and it is neglected in this model. In this study, three methods are presented for four parameters model. Explicit simplified method based on an analytical solution, slope method based on manufacturer data, and iterative method based on a numerical resolution. The results obtained for these methods were compared with experimental measured data. The iterative method was more accurate than the other two methods but more complexity. The average deviation of
... Show MoreA simple, accurate and precise spectrophotometric method has been developed for the analysis of sulfamethoxazole (SMZ) in pure form and pharmaceutical preparation. The method involves a direct charge transfer complexation of sulfamethoxazole (SMZ) with sodium nitroprusside (SNP) in alkaline medium and the presence of hydroxyl amine hydrochloride. Variables affecting the formation of the formed orange colored complex were optimized following two approaches univariate and central composite experimental design (CCD) multivariate. Under optimum recommended conditions, the formed complex exhibits λmax at 512 nm and the method conforms Beer's law for SMZ concentration in the range of 5.0-150.0 (µg.mL-1) with molar absorptivi
... Show MoreAbstract
This paper is an experimental work to determinate the effect of welding velocity and formed arc energy for CO2-MAG fusion weld pool. The input parameters (arc voltage, wire feed speed and gas flow rate) were investigated to find their effects on the weld joint efficiency. Design of experiment with response surface methodology technique was used to build empirical mathematical models for welding velocity and arc energy in term of the input welding parameters. The predicted quadratic models were statistically checked for adequacy purpose by ANOVA analysis. Additionally, numerical optimization was conducted to obtain the optimum values for welding velocity and arc energy. A good agree
... Show MoreMedicines comprising fosfomycin are prescribed for urinary tract infections. These drugs are available for oral use as tromethamine and calcium, while fosfomycin-sodium and disodium are given for intravenous (IV) and intramuscular (IM). Many quantitative analytical methods have been reported to estimate Fosfomycin in blood, urine, plasma, serum, and pharmaceutical dosage formulations. Some techniques were spectrophotometric, mass spectrometry, gas chromatography, high-performance liquid chromatography, and electrochemical methods. Here we perform a rapid narrative review that discusses and comparison between them of various analytical methods for the determination of Fosfomycin-containing drugs.
A simple, accurate and sensitive spectrophotometric method for the determinaion of epinephrine is described . The method is based on the coordination of Pr (III) with epinephrine at pH 6. Absorbance of the resulting orange yellow complex is measured at 482 nm . A graph of absorbance versus concentrations shows that beer 's low is obeyed over the concentration range (1-50)mg.ml-1 of epinephrine with molar absorpitivity of ( 2.180x103 L.mol-1.cm-1 ), a sandell sensitivity of (0.084 mg.cm-2 ), a relative error of (-2.83%) , a corrolation coffecient (r= 0.9989) and recovery % ( 97.03 ± 0.75 ) depending on the concentration.This method is applied to analyse EP in several commercially available pharmaceutical preparations
... Show MoreThis research involves an indirect Fluorophotometric method for the determination of microgram amount of oxymetazoline hydrochloride in the concentration range 0.1-5.0 g/ml. The method is based on the oxidation of the drug by cerium sulphate solution which is acidic medium where Ce IV is reduced to Ce III which can be excited at 259 nm to give an emitted light at 377 nm which is directly proportional to the concentration of Ce III which is equivalent to Ce IV that is needed to oxidize the studied drug. The average recovery of the method is 100.19% and relative standard deviation (RSD) < 0.37% . The method have been successfully applied to the determination of the studied drug in its pure and pharmaceutical preparations and it wa
... Show MoreAn accurate and sensitive spectrophotometric method has been developed for the determination of cefotaxime (CEF) in pure and pharmaceutical samples. The suggested method depended on the coupling reaction between diazotized cefotaxime and 3,5-dimethyl phenol (3,5-DMPH) in basic medium to form light orange, water soluble dye, that is stable and has a maximum absorbance at 497nm. The calibration graph was liner over the concentration range (1-70) µg.mL-1 with LOD of 0.750 µg.mL-1 and LOQ of. 2.740 µg. mL-1, sandal sensitivity of 0.0526 µg. cm-2 . molar absorptivity 11328 Lmol-1 cm-1 . The stoichiometry composition was found by Jobs a
... Show More