Preferred Language
Articles
/
3nh4fKABuRolNscLqe-8
Surface Roughness Examination of Glass Ionomer Restorative Cements Treated with Acidic and Basic Pediatric Medications: An In Vitro Study
...Show More Authors
A <sc>bstract</sc> <sec> <title>Background:

Consumption of different types of beverages and liquid drugs can affect of the surface properties of restorative material. This may lead to an increased probability of dental caries and periodontal inflammation.

Aim:

This study evaluated and compared the effect of amoxicillin suspension (AMS) and azithromycin suspension (AZS) on the surface roughness (SR) of silver-reinforced glass ionomer (SGI) and nano resin-modified glass ionomer (NGI).

Material and Methods:

Thirty disks (2 mm height × 4 mm diameter) of each glass ionomer (GI) type were prepared and subdivided into three groups ( n = 10), which were separately exposed to AMS, AZS, and artificial saliva (AS). SR was evaluated by atomic force microscopy before and after three-immersion protocols repeated over a 3-week duration with 2-day intervals. In each protocol, the GI samples were exposed weekly to AMS three times daily, AZS once daily, and a full day to AS.

Results:

This study demonstrated, for the first time, the effect of a basic drug (AZS) on the SR of GIs. Intra- and inter-group comparisons showed significant changes ( P ˂ 0.05) in the SR pattern of the GIs after immersion cycles in AZS, AMS, and AS. However, the acidic medication (AMS) exhibited significantly higher changes in SGI than in NGI.

Conclusions:

The SR of NGIs and SGIs can be significantly affected by the use of AMS and AZS suspensions. SGI demonstrated higher SR deterioration than NGI after immersion cycles in AMS.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
An Experimental Study of the Effects of Coolant Fluid on Surface Roughness in Turning Operation for Brass Alloy
...Show More Authors

The effect of different cutting fluids on surface roughness of brass alloy workpiece during turning operation was carried out in this research. This was performed with different cutting speed, while other cutting parameters had been regarded as constants(feeding rate , and depth of cut). Surface roughness of machined parts that will be tested by electronic surface roughness tester .The results show that the standard coolant gives the best values of surface roughness for fixed cutting speed ,followed by sun flower oil that has approximately the same effect, while the air stream as a coolant gave unsatisfied results for the evaluation of surface roughness.

In the other hand the best values of surface roughness were recorded for max

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Effect of Dentin Surface Pretreatment With Chitosan Nanoparticles on Immediate and Prolonged Shear Bond Strength of Resin Composite: An in Vitro Study
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Microleakage of Pit and Fissure Sealants after Using Different Occlusal Surface Preparation Techniques: An In Vitro Study
...Show More Authors

Background: The marginal seal is essential for sealant success because penetration of bacteria under the sealant might allow caries onset or progression. The aim of the present study was to estimate and compare the microleakage of pit and fissure sealant after various methods of occlusal surface preparation. Materials and methods: Thirty non-carious premolars extracted for orthodontic reasons were equally divided into three groups. In group one, occlusal fissures were opened with round carbide bur, in group two, occlusal surfaces of the teeth were cleaned with a dry pointed bristle brush and samples of group three were cleaned with a slurry of fine flour of pumice in water using rubber cup. Then fissures of all teeth were etched using 35% p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Effect of Amoxicillin and Azithromycin Suspensions on Microhardness of Sliver Reinforced and Nano Resin-Modified Glass Ionomers: An In Vitro Study
...Show More Authors

We aimed to examine the effect of amoxicillin and azithromycin suspensions on the microhardness of sliver-reinforced glass ionomer and nano-resin modified glass ionomer (GI). Method: Thirty discs (2mm height x 4mm diameter) of each type of GI were prepared, which were randomly assigned to amoxicillin, azithromycin, and artificial saliva groups. Microhardness was evaluated by Vickers hardness test before and after three immersion cycles. Results: The overall model (P < 0.001), before/after intervention (P < 0.001), intervention group (type of antibiotic) (P=0.013), and type of glass ionomer (P < 0.001) showed significant differences among study groups (P < 0.001). Post hoc test showed only non-significant before/after difference for Azithrom

... Show More
View Publication Preview PDF
Crossref (5)
Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Artificial Accelerated Aging on The Color of Ceramic Veneers Cemented With Different Resin Cements (A Comparative In Vitro Study)
...Show More Authors

ABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Enamel Surface after Debonding of Different Types of Esthetic Brackets (An In Vitro Study)
...Show More Authors

Background: Debonding orthodontic brackets and removal of residual bonding material from the enamel surface include critical steps that may cause enamel damage. The aim of the present study was to evaluate and compare the site of bond failure and enamel surface damage after debonding of three types of esthetic brackets (composite, ceramic, sapphire) bonded with light cure composite and resin-modified glass ionomer adhesive. Materials and methods: Seventy two maxillary premolars teeth were divided into three groups each group consisted of 24 teeth according to the type of brackets. Each group was subdivided into two subgroups (12 teeth for each) according to the bonding material that was used. After 7 days of bonding procedure, the brackets

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Oct 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of fracture strength of endodontically treated teeth restored by milled zirconia post and core with different post and core systems (An in vitro comparative study)
...Show More Authors

Background: Restoration of root canal treated teeth with a permanent restoration affect in the success of endodontically treated teeth. This in vitro study was performed to evaluate and compare the fracture strength of endodontically treated teeth restored by using custom made zirconium posts and cores, prefabricated carbon fiber, glass fiber and zirconium ceramic posts. Materials and method: Forty intact human mandibular second premolars were collected for this study and were divided into five groups. Each group contains 8 specimens: Group1: Teeth restored with Carbon Fiber Posts; Group2: Teeth restored with Glass Fiber Posts; Group3: Teeth restored with Zirconium Ceramic prefabricated Posts; Group4: Teeth restored with Zirconium Posts

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effects of Nano-Hydroxyapatite and Casein Phosphopeptide-Amorphous Calcium Phosphate in Preventing Loss of Minerals from Teeth after Exposure to an Acidic Beverage (An In vitro Study)
...Show More Authors

Background: To evaluate the effect of antierosive agents (10% Nano-Hydroxyapatite (NHA), 10% Casein Phophopeptide-Amorphous Calcium Phosphate (CPP-ACP), and combination of 10% NHA and 10% CPP-ACP) on loss of minerals from enamel surface of permanent teeth treated with antierosive agents when exposed to an acidic beverage and investigate the morphological changes of treated enamel surface after demineralization with cola based beverage under Scanning Electron Microscope (SEM). Materials and Methods: Sixty maxillary first premolars were randomly divided into four groups, 15 teeth for each group. Group I treated with 10% NHA, Group II treated with 10% CPP-ACP, Group III treated with 10% NHA and 10% CPP-ACP, and Group IV did not treat with any

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the therm

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the

... Show More
Crossref (1)
Crossref