Dental implants are considered a unique treatment alternative for the replacement of missing dentition. There is a strive for materials which increase bone formation in bone implant interface and improve osseointegration to offer immediate loading directly after placement with decreased time. The aim of the study was to assess the effect of nano strontium substituted hydroxyapatite and nano fluorapatite mixture coating of screw shaped commercially pure titanium at the bone implant interface by torque removal test and histological assessment in rabbit tibia. Commercially pure titanium was used to prepare 80 screws that were divided into machined surfaces (CpTi), coated with (SrHA), coated with (FA) and coated with mixture 50%SrHA + 50%FA (mixed). The dip coating process was used for producing a homogenous coating layer. Biomechanical and histological assessments were completed after 2 and 6 weeks of implantation. The results revealed that the mean removal torque value for the mixed group were significantly greater when compared with CpTi group, SrHA group, and FA group after 2 and 6 weeks There was more new bone formation around the screws for the mixed group for both healing intervals. Mixing nano strontium substituted hydroxyapatite and nano fluorapatite was more effective in increasing torque mean values, in addition to higher bone formation after 2 and 6 weeks as a result of combined effect of strontium, fluoride in coating.
Objective: The study aims at assessing the food frequency intake and dietary habits for diabetic pregnant
women.
Methodology: A descriptive study is carried out for the period from November4th 2013 to August
25th 2014. A purposive "non-probability" sample of one hundred diabetic pregnant women is selected from
the Diabetic and Endocrine Center in Al-Amarha City. A questionnaire is developed as a tool of data
collection. Content validity of the study instrument is determined through panel of experts. Split-half
reliability technique is used for reliability determination of the study instrument which depicts a reliability
coefficient of (0.79) for the entire scale. A structured interview with each diabetic pregnant wom
The Central Marshes are one of southern Iraq's most important wetlands and ecosystems. A study on evaluating soil quality and water quality in terms of chemical properties at certain sites in the southern Iraqi Central Marshes has been conducted to investigate their types and suitability for enhancing the agricultural reality of most field crops. Soil and water samples were collected from 15 sites and transferred to the laboratory. In the lab, the following parameters were determined: electrical conductivity (EC), total dissolved salts (TDS), organic materials (OM), pH, gypsum, and total sulfate content (SO3). The tests conducted on the samples indicated that it could be said that the soil of the Central Marshes
... Show MoreThe knowledge related with lexical items can be realized as including relations of meaning a cross words. Words that share a similarity of meaning are called to be synonymous, and words that share a contrary of meaning are called to be antonymous. Both of them are universal linguistic phenomenon that exist in terms of linguistic system of every language. The present study aims at finding out areas of difficulty that Iraqi EFL learners encounter in the use of synonymy and antonymy, both on the recognition and production levels. Also tries to detect the main reasons behind such difficulties. A diagnostic test of two parts, namely, recognition and production, is designed. The test is built to include two linguistic phenomenon which are: synony
... Show MoreIn this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.
Titanium dioxide (TiO2) thin films were prepared under different pressures with values (15, 30, 60 and 120) Pa using the DC reactive magnetron homemade system with mixed gases of argon and oxygen in ratio (50:50). The result of X-ray diffraction patterns discovered that the structure of the deposited films was polycrystalline, including the phase of anatase. All the appeared peaks were matched to the planes (101), (004), (105), and (211) of diffracted states. Both the intensities and the number of the appeared peaks are declined according to the increased pressure, and the plane of (101) is be considered the preferential grown plane, it is taking a maximum texture factor. Both the lattice constant and the atomic inter-planer spacing take th
... Show MoreBackground: Beta thalassemia major is an inherited disorder that may affect general and oral health.The purpose of this study was toassess the severity of dental caries in relation to oral cleanliness, mutans streptococciamong a group of boys with beta thalassemia majorin comparison with a control group. Materials and Methods: The study involved 30 boys with BTM aged 10-12 years compared to 30 healthy boys with the same age group. d1-4mfs and D1-4 MFS indices were applied (Muhlemann, 1976), the viable counts of mutans streptococci in stimulated saliva were also determined. Results: The entire thalassemic group was caries-active. For both dentitions, a higher dmfs/DMFS values were recorded for study compared to control group, difference was
... Show MoreThis study evaluated the effect of two different types of amino group-containing pharmacological inhibitors on titanium corrosion under acidic conditions. The first inhibitor examined was the antibiotic trimethoprim. The second inhibitor studied was the nonsteroidal anti-inflammatory drug voltaren. The results showed that titanium had a high corrosion current in the absence of a corrosion inhibitor, however, trimethoprim notably enhanced corrosion resistance and protection percentages of titanium (%IE) at higher concentrations by adhering to the metal surface, as evidenced by improved protection percentages. Furthermore, the results showed that as Voltaren concentration was increased, both corrosion resistance and inhibition efficie
... Show More