Introduction: In recent decades, the endovascular treatment of cerebral arteriovenous malformations (AVMs) has advanced. However, it still carries risks of unanticipated complications. Coil migration is a reported complication of aneurysmal coiling procedures. Herein, we report a case of early intraprocedural coil migration during pressure cooker technique embolization of right thalamic AVM, discussing the management and potential explanations. The literature showed no report of coil migration after the pressure cooker technique in the form of coil-augmented Onyx injection technique (CAIT). Case description: An otherwise healthy 26-year-old female suddenly developed a severe headache with no loss of consciousness. Computed tomography (CT) scan of the head illustrated intraventricular haemorrhage. Magnetic resonance imaging (MRI) showed the bag of worms' sign in the right thalamic area. The size and location of the AVM prompted the decision for multistage endovascular embolization using onyx. In the anterior circulation, the right A5 arterial feeder has a high flow which indicates the pressure cooker technique embolization in the form of CAIT. In the procedure, early detachment and migration of the coil occurred in the medial prefrontal branch through the anterior cerebral artery. No intervention to retrieve the coil was carried out because the detachment piece is small and lodged distally. Onyx was injected directly without the coil because of the risk of radiation to the patient. Otherwise, the intraprocedural and postprocedural courses went uneventful. Conclusion: This is the first report of coil migration during the pressure cooker technique with CAIT for the right thalamic AVM.
To ascertain the stability or instability of time series, three versions of the model proposed by Dickie-Voller were used in this paper. The aim of this study is to explain the extent of the impact of some economic variables such as the supply of money, gross domestic product, national income, after reaching the stability of these variables. The results show that the variable money supply, the GDP variable, and the exchange rate variable were all stable at the level of the first difference in the time series. This means that the series is an integrated first-class series. Hence, the gross fixed capital formation variable, the variable national income, and the variable interest rate
... Show MoreMost of the medical datasets suffer from missing data, due to the expense of some tests or human faults while recording these tests. This issue affects the performance of the machine learning models because the values of some features will be missing. Therefore, there is a need for a specific type of methods for imputing these missing data. In this research, the salp swarm algorithm (SSA) is used for generating and imputing the missing values in the pain in my ass (also known Pima) Indian diabetes disease (PIDD) dataset, the proposed algorithm is called (ISSA). The obtained results showed that the classification performance of three different classifiers which are support vector machine (SVM), K-nearest neighbour (KNN), and Naïve B
... Show MoreGlobally, over forty million people are living with Human Immunodeficiency Viral (HIV) infections. Highly Active Antiretroviral Therapy (HAART) consists of two or three Antiretroviral (ARV) drugs and has been used for more than a decade to prolong the life of AIDS-diagnosed patients. The persistent use of HAART is essential for effectively suppressing HIV replication. Frequent use of multiple medications at relatively high dosages is a major reason for patient noncompliance and an obstacle to achieving efficient pharmacological treatment. Despite strict compliance with the HAART regimen, the eradication of HIV from the host remains unattainable. Anatomical and Intracellular viral reservo
An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination
... Show More