Abstract
Objective : the aim of the study is to evaluate the effectiveness of nurse’s practices and knowledge program toward care of patient with cardiopulmonary bypass .Methodology: A pre-experimental design (one group pretest- posttest design) was used to carry out this study in three governmental hospitals in Baghdad ( Iraqi Centre for Heart Diseases , Ibn – Albitar Centre for Cardiac Surgery and Ibn – Alnafees Centre for Cardiothoracic and Vascular Surgery ) for the period from 15th of May 2022 into 20th of April 2023.The construction and development of the program and instruments had carry out by the researcher to measured the purposes of the study , twenty two nurses was purposively assigned for the study group . The
... Show MoreSome transition metal ions (Cr +3, Co+2 , Ni+2,Cu+2, Zn+2,Ag + ,Cd+2 ) complexes of [(N, N- - Bis(2- hydroxy ethyl) Glycine] (Bicine) have been synthesized and characterized by FTIR ,UV-Visble spectroscopy, atomic absorption, magnetic susceptibility, conductivity measurements and study of the nature of the complexes formed in ethanolic solution following the moleratio method. From the results obtained the following general formola have been given for the prepared complexes [M m+ (Bicine)n]. XH2O
Synthesis of new Fe+3, Co+2, Cu+2, Ru+3, and Rh+3 complexes of azo ligand; [5-((2-(3 H-1 indol-3-yl) ethyl) diazenyl) quinolin-8-ol], of 1:2 (M: L) and characterized through various techniques. The complexes exhibited octahedral geometries. Thermogravimetric (TGA and DSC) analysis is utilized to study the thermal properties of various compounds and reveal the presence of coordinated water molecules in the complexes. The multi-stage thermal decomposition mechanisms, where the thermal breakdown is ended by the formation of metal oxide as the final stable residue. The antioxidant activity of the ligand and its metal complexes was evaluated using the DPPH free radical scavenging assay and Gallic acid as a standard substance. Among the tested co
... Show MoreIn this paper the process of metal ions extraction (Zn(II) and Cu(II)) was studied in PEG-KCl aqueous two phase system was investigated without using an extracting agent. The experimental runs were performance at constant temperature (25 oC), constant mixing time (30 min), and constant PH of the solution (about 3). The effect of KCl salt concentration (from 10% to 25%), volumetric phase ratio of PEG solution to KCl solution (from 0.5 to 2), and the initial metal ion concentration (from 0.25 ml to 2 ml of 1 gm/L solution) were investigated on the percent extraction of Zn(II) and Cu(II). The results indicated that the percent extraction of metal ions increase with increasing of salt concentration and phase ratio, and slightly de
... Show MoreObjectives To compare the clinical efficacy of microvascular decompression surgery (MVD) and gamma knife radiosurgery (GKR) as a treatment for patients with primary trigeminal neuralgia (TN) and evaluate the outcome regarding pain relief, recurrence, and complications with both modalities of treatment. Patients and Methods A randomized prospective study conducted in SaadAlwitry Neurosciences Hospital, Baghdad, Iraq. Eighty-four patients with TN from January 2016 to January 2018, 45 patients had GKR while 39 patients treated with MVD. The pain evaluated pre-and post-operatively using the Barrow Neurological Institute Pain Intensity scale (BNIPI), visual analog scale (VAS) and Brief Pain Inventory Facial (BPI-Facial) scoring systems. In GKR p
... Show MoreThis paper was aimed to evaluate the polyurethane (PU) and polyurethane/polyvinyl chloride (90 wt. % / 10 wt. %) as organic coating of carbon steel substrate against marine environment (3.5 wt.% NaCl aqueous solution) as a severe corrosion environment . The electrochemical impedance spectroscopy (EIS) and fitting impedance data by ZsimpWin 3.22 software were used to estimate the physical barrier of the samples for different exposure times. Different equivalent electrical circuits were proposed for the physical barrier at different immersion times to get appropriate fitting .Both PU and PU/PVC coatings showed excellent corrosion protection ability for steel .The PU/PVC coating showed better protection and stability than PU coating against
... Show More